Zurück zur Übersicht

Endress+Hauser: Promass 83 with EtherNet/IP affected by a stack-based buffer overflow

VDE-2021-040
Last update
14.05.2025 14:28
Published at
04.10.2021 14:30
Vendor(s)
Endress+Hauser AG
External ID
VDE-2021-040
CSAF Document

Summary

Promass 83 devices utilizing 499ES EtherNet/IP (ENIP) Stack by Real Time Automation (RTA) are vulnerable to a stack-based buffer overflow.

Update A, 2021-10-07:

added credits
changed title from "ENDRESS+HAUSER: Promass 83 with Ether/IP affected by DoS vulnerability" to "ENDRESS+HAUSER: Promass 83 with EtherNet/IP affected by a stack-based buffer overflow"

Impact

The vulnerability described can lead to a denial of service or even remote code execution.

Affected Product(s)

Model no. Product name Affected versions
Promass 83 Firmware 1.00.00

Vulnerabilities

Expand / Collapse all

Published
02.09.2026 14:29
Weakness
Stack-based Buffer Overflow (CWE-121)
Summary

499ES EtherNet/IP (ENIP) Adaptor Source Code is vulnerable to a stack-based buffer overflow, which may allow an attacker to send a specially crafted packet that may result in a denial-of-service condition or code execution.

References

Mitigation

If an immediate firmware update is not possible, the only way to prevent an attack is to disable communication via EtherNet/IP.

Remediation

Endress+Hauser provides updated firmware versions (Firmware versions >1.00.00) for the related product from the Proline portfolio which fixes the vulnerability. Endress+Hauser strongly recommends customers to update to the new fixed version. For support, please contact your local service center.

Acknowledgments

Endress+Hauser AG thanks the following parties for their efforts:

  • CERT@VDE for coordination (see https://certvde.com )
  • Sharon Brizinov from Claroty for reported

Revision History

Version Date Summary
1 04.10.2021 14:30 Initial revision.
2 07.10.2021 12:00 Update A
3 14.05.2025 14:28 Fix: firmware category, added distribution