View CSAF 1. EXECUTIVE SUMMARY CVSS v4 5.9 ATTENTION: Exploitable from an adjacent network/low attack complexity Vendor: ZF Equipment: RSSPlus Vulnerability: Authentication Bypass By Primary Weakness 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthenticated attacker to remotely (proximal/adjacent with RF equipment) call diagnostic functions which could ...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY ...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY ...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY ...
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 4.9 ATTENTION: Low attack complexity Vendor: Hitachi Energy Equipment: FOX61x, FOXCST, FOXMAN-UN Vulnerability: Improper Validation of Certificate with Host Mismatch 2. RISK EVALUATION Successful exploitation of this vulnerability could allow attackers to intercept or falsify data exchanges between the client and the server. ...
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 4.9 ATTENTION: Exploitable remotely/low attack complexity Vendor: Hitachi Energy Equipment: FOX61x Products Vulnerability: Relative Path Traversal 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to traverse the file system to access files or directories that would otherwise be inaccessible. ...
Note: The CVEs in this advisory are unrelated to vulnerabilities (CVE-2025-0282 and CVE-2025-0283) in Ivanti’s Connect Secure, Policy Secure and ZTA Gateways. For more information on mitigating CVE -2025-0282 and CVE-2025-0283, see Ivanti Releases Security Updates for Connect Secure, Policy Secure, and ZTA Gateways. Summary The Cybersecurity and Infrastructure Security ...
Several camera device drivers in the Siveillance Video Device Pack store camera credentials in their log file when authentication fails. This could allow a local attacker to read camera credentials stored in the Recording Server under specific conditions. Siemens has released an update of the Device Pack and recommends to ...
BOSCH-SA-904062-BT: An unquoted service path enumeration vulnerability on SMCWatchDog agent has been found affecting the DIVAR IP all-in-one 7000 (DIP-72xx) devices. This vulnerability can allow a local attacker to gain elevated privileges.
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low Attack Complexity Vendor: Schneider Electric Equipment: Vijeo Designer Vulnerability: Improper Privilege Management 2. RISK EVALUATION Successful exploitation of these vulnerabilities could cause a non-admin authenticated user to perform privilege escalation by tampering with the binaries. 3. TECHNICAL DETAILS 3.1 AFFECTED ...
The OPC UA implementations (ANSI C and C++) as used in several SIMATIC products contain a denial of service vulnerability that could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate. Siemens has released new versions for several affected products and ...
A vulnerability in the login dialog box of SIMATIC WinCC could allow a local attacker to cause a denial of service condition in the runtime of the SCADA system. Siemens has released new versions for the affected products and recommends to update to the latest versions.
SSA-723487 V1.4 (Last Update: 2025-01-14): RADIUS Protocol Susceptible to Forgery Attacks (CVE-2024-3596) - Impact to SCALANCE, RUGGEDCOM and Related Products
This advisory documents the impact of CVE-2024-3596 (also dubbed “Blastradius”), a vulnerability in the RADIUS protocol, to SCALANCE, RUGGEDCOM and related products. The vulnerability could allow on-path attackers, located between a Network Access Server (the RADIUS client, e.g., SCALANCE or RUGGEDCOM devices) and a RADIUS server (e.g., SINEC INS), to ...
Affected products do not properly sanitize user-controllable input when parsing files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures for ...
Several SIMATIC S7-1500 and S7-1200 CPU versions are affected by an open redirect vulnerability that could allow an attacker to make the web server of affected devices redirect a legitimate user to an attacker-chosen URL. For a successful attack, the legitimate user must actively click on an attacker-crafted link. Siemens ...
A Socket.IO vulnerability affects multiple Siemens industrial products. This vulnerability consists of a specially crafted Socket.IO packet that triggers an uncaught exception on the Socket.IO server killing the Node.js process allowing a remote attacker to cause Denial-of-Service condition in the affected products. Siemens has released new versions for several affected ...
The web interface of SIMATIC S7-1200 CPUs before V4.7 is affected by a cross-site request forgery (CSRF) vulnerability. Siemens has released new versions for the affected products and recommends to update to the latest versions.
Several SIMATIC S7-1500 CPU versions are affected by an authentication bypass vulnerability that could allow an unauthenticated remote attacker to gain knowledge about actual and configured maximum cycle times and communication load of the CPU. Siemens has released new versions for several affected products and recommends to update to the ...
Siemens User Management Component (UMC) before V2.11.2 is affected by multiple vulnerabilities where the most severe could lead to a restart of the UMC server. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes ...
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version V3.1 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not ...
The Mendix LDAP module is affected by an LDAP injection vulnerability that could allow an unauthenticated remote attacker to bypass username verification. Siemens has released a new version for Mendix LDAP and recommends to update to the latest version.
Affected SIPROTEC 5 devices do not properly limit the access of the web server to the filesystem. This could allow an authenticated remote attacker to read arbitrary files or the entire filesystem of the device. Siemens has released new versions for several affected products and recommends to update to the ...
Affected models of the S7-1500 CPU product family do not contain an Immutable Root of Trust in Hardware. With this the integrity of the code executed on the device can not be validated during load-time. An attacker with physical access to the device could use this to replace the boot ...