• 1 (current)
  • 2
Donnerstag, 19.12.2019
Titel
Philips Veradius Unity, Pulsera, and Endura Dual WAN Routers
Veröffentlicht
19. Dezember 2019 16:30
Text
This advisory contains mitigations for an inadequate encryption strength vulnerability in certain Philips WAN routers.
Titel
Moxa EDS Ethernet Switches
Veröffentlicht
19. Dezember 2019 16:25
Text
This advisory contains mitigations for an uncontrolled resource consumption vulnerability in Moxa EDS Ethernet Switches.
Titel
Equinox Control Expert
Veröffentlicht
19. Dezember 2019 16:20
Text
This advisory contains mitigations for an SQL injection vulnerability in Equinox's Control Expert HMI/SCADA management platform.
Titel
Reliable Controls MACH-ProWebCom/Sys
Veröffentlicht
19. Dezember 2019 16:10
Text
This advisory contains mitigations for a cross-site scripting vulnerability in Reliable Controls' MACH-ProWebCom/Sys web enabled building controllers.
Titel
AVEVA Vijeo Citect and Citect SCADA (Update A)
Veröffentlicht
19. Dezember 2019 16:00
Text
This updated advisory is a follow-up to the original advisory titled “ICSA-19-290-01 AVEVA Vijeo Citect and Citect SCADA” that was published October 17, 2019, on the ICS webpage on us-cert.gov. This advisory contains mitigations for a stack-based buffer overflow vulnerability in the AVEVA Vijeo Citect and Citect SCADA.
Dienstag, 17.12.2019
Titel
GE S2020/S2020G Fast Switch 61850
Veröffentlicht
17. Dezember 2019 16:05
Text
This advisory contains mitigations for a cross-site scripting vulnerability in GE's S2020/S2020G Fast Switch 61850 Ethernet switches.
Titel
Siemens SPPA-T3000
Veröffentlicht
17. Dezember 2019 16:00
Text
This advisory contains mitigations for numerous vulnerabilities in Siemens' SPPA-T3000 servers.
Dienstag, 10.12.2019
Titel
Siemens SCALANCE W700 and W1700
Veröffentlicht
10. Dezember 2019 17:05
Text
This advisory contains mitigations for an improper enforcement of message integrity during transmission in a communication channel vulnerability in the Siemens SCALANCE W700 and W1700 wireless communication devices.
Titel
Siemens SiNVR 3
Veröffentlicht
10. Dezember 2019 17:00
Text
This advisory contains mitigations for cleartext storage of sensitive information in GUI, improper authentication, relative path traversal, missing authentication for critical function, weak cryptography for passwords, and exposed dangerous method or function vulnerabilities in the Siemens SiNVR 3 video management solution.
Titel
Siemens RUGGEDCOM ROS
Veröffentlicht
10. Dezember 2019 16:55
Text
This advisory contains mitigations for improper restriction of operations within the bounds of a memory buffer and resource management errors vulnerabilities in the Siemens RUGGEDCOM ROS ethernet switch.
Titel
Siemens SIMATIC Products
Veröffentlicht
10. Dezember 2019 16:50
Text
This advisory contains mitigations for an exposed dangerous method or function vulnerability in Siemens' SIMATIC products.
Titel
Siemens XHQ Operations Intelligence
Veröffentlicht
10. Dezember 2019 16:45
Text
This advisory contains mitigations for cross-site request forgery, improper neutralization of script-related HTML tags in a web page, and improper input validation vulnerabilities in the Siemens XHQ Operations Intelligence products.
Titel
Siemens SIMATIC S7-1200 and S7-1500 CPU Families
Veröffentlicht
10. Dezember 2019 16:40
Text
This advisory contains mitigations for a use of a broken or risky cryptographic algorithm, and missing support for integrity check vulnerabilities in the Siemens SIMATIC S7-1200 and S7-1500 CPU families.
Titel
Siemens S7-1200 and S7-200 SMART CPUs (Update A)
Veröffentlicht
10. Dezember 2019 16:30
Text
This updated advisory is a follow-up to the original advisory titled ICSA-19-318-02 Siemens S7-1200 that was published November 14, 2019, on the ICS webpage on us-cert.gov. This advisory contains information and mitigation recommendations for an exposed dangerous method or function vulnerability in the Siemens S7-1200 and S7-200 SMART CPUs.
Titel
Interpeak IPnet TCP/IP Stack (Update B)
Veröffentlicht
10. Dezember 2019 16:25
Text
This updated advisory is a follow-up to the updated advisory titled ICSA-19-274-01 Interpeak IPnet TCP/IP Stack (Update A) that was published October 10, 2019, on the ICS webpage on us-cert.gov. This advisory contains mitigations for stack-based buffer overflow, heap-based buffer overflow, integer underflow, improper restriction of operations within the bounds ...
Titel
Siemens Industrial Products (Update C)
Veröffentlicht
10. Dezember 2019 16:20
Text
This updated advisory is a follow-up to the updated advisory titled ICSA-19-253-03 Siemens Industrial Products (Update B) that was published November 14, 2019, on the ICS webpage on us-cert.gov. This updated advisory includes mitigations for integer overflow or wraparound and uncontrolled resource consumption vulnerabilities reported in Siemens’ industrial products.
Titel
SSA-273799 (Last Update: 2019-12-10): Vulnerability in SIMATIC products
Veröffentlicht
10. Dezember 2019 01:00
Text
A vulnerability has been identified in several SIMATIC products. The vulnerability could allow an attacker in a Man-in-the-Middle position to modify network traffic exchanged on port 102/tcp to PLCs of the SIMATIC S7-1200, SIMATIC S7-1500 and SIMATIC SoftwareController CPU families. Siemens has released updates for several affected products, and recommends ...
Titel
SSA-603476 (Last Update: 2019-12-10): Web Vulnerabilities in SIMATIC CP 343-1/CP 443-1 Modules and SIMATIC S7-300/S7-400 CPUs
Veröffentlicht
10. Dezember 2019 01:00
Text
SIMATIC CP 343-1 Advanced/CP-443-1 Advanced devices and SIMATIC S7-300/S7-400 CPUs are affected by two vulnerabilities. One of the vulnerabilities could allow remote attackers to perform operations as an authenticated user under certain conditions. Siemens has released updates for SIMATIC CP 343-1 Advanced and SIMATIC CP 443-1 Advanced devices. Siemens recommends ...
Titel
SSA-451445 (Last Update: 2019-12-10): Multiple Vulnerabilities in SPPA-T3000
Veröffentlicht
10. Dezember 2019 01:00
Text
SPPA-T3000 Application Server and MS3000 Migration Server are affected by multiple vulnerabilities. Some of the vulnerabilities can allow an attacker to execute arbitrary code on the server. Exploitation of the vulnerabilities described in this advisory requires access to either Application- or Automation Highway. Both highways should not be exposed if ...
Titel
SSA-525454 (Last Update: 2019-12-10): Vulnerabilities in XHQ Operations Intelligence
Veröffentlicht
10. Dezember 2019 01:00
Text
Multiple vulnerabilities have been identified in XHQ Operations Intelligence product line. These vulnerabilities could allow for data injection in XHQ's web interfaces. Siemens recommends to update XHQ Operations Intelligence product line to the newest version.
Titel
SSA-418979 (Last Update: 2019-12-10): Vulnerabilities in EN100 Ethernet Communication Module
Veröffentlicht
10. Dezember 2019 01:00
Text
The EN100 Ethernet communication modules are affected by security vulnerabilities which could allow an attacker to disclose information. Siemens has released updates for several affected products, is working on updates for the remaining affected products, and recommends specific countermeasures until fixes are available.
Titel
SSA-189842 (Last Update: 2019-12-10): TCP URGENT/11 Vulnerabilities in RUGGEDCOM Win
Veröffentlicht
10. Dezember 2019 01:00
Text
RUGGEDCOM Win is affected by multiple security vulnerabilities. These vulnerabilities could allow an attacker to leverage various attacks, e.g. to execute arbitrary code over the network. The vulnerabilities affect the underlying Wind River VxWorks network stack and were recently patched by Wind River. Siemens is working on updates for the ...
Titel
SSA-761617 (Last Update: 2019-12-10): Multiple Vulnerabilities in SiNVR Video Management Solution
Veröffentlicht
10. Dezember 2019 01:00
Text
SiNVR V3 contains seven vulnerabilities in the components Video Server and Central Control Server (CCS), involving authentication bypass (CVE-2019-18337, CVE-2019-18339, CVE-2019-18341), information disclosure (CVE-2019-13947, CVE-2019-18340), path traversal (CVE-2019-18338), and privilege escalation (CVE-2019-18342). Siemens recommends specific countermeasures until fixes are available.
Titel
SSA-899560 (Last Update: 2019-12-10): Vulnerabilities in SIPROTEC 5 relays and DIGSI 5
Veröffentlicht
10. Dezember 2019 01:00
Text
The SIPROTEC 5 relays and their corresponding engineering software DIGSI 5 are affected by two security vulnerabilities which could allow an attacker to upload or download files to the device or to conduct a Denial-of-Service attack over the network. Siemens has released updates for some affected products, is working on ...
Titel
SSA-530931 (Last Update: 2019-12-10): Denial-of-Service in Webserver of Industrial Products
Veröffentlicht
10. Dezember 2019 01:00
Text
A vulnerability in the affected products could allow an unauthorized attacker with network access to the webserver of an affected device to perform a denial-of-service attack. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates and recommends ...
  • 1 (current)
  • 2

Letzte Updates

BOSCH PSIRT
31.10.2024
SIEMENS CERT
26.11.2024
US CERT
08.11.2024
US CERT (ICS)
03.12.2024

Nach Quelle

Archiv

2024
2023
2022
2021
2020
2019
2018
2017

Feeds