August 2022
Titel
AA22-228A: Threat Actors Exploiting Multiple CVEs Against Zimbra Collaboration Suite
Veröffentlicht
16. August 2022 17:38
Text
Original release date: August 16, 2022SummaryActions for ZCS administrators to take today to mitigate malicious cyber activity: • Patch all systems and prioritize patching known exploited vulnerabilities. • Deploy detection signatures and hunt for indicators of compromise (IOCs). • If ZCS was compromised, remediate malicious activity. The Cybersecurity and Infrastructure ...
Titel
Yokogawa CENTUM Controller FCS
Veröffentlicht
16. August 2022 16:35
Text
This advisory contains mitigations for a Denial of Service vulnerability in CENTUM Controller FCS products.
Titel
LS ELECTRIC PLC and XG5000
Veröffentlicht
16. August 2022 16:30
Text
This advisory contains mitigations for an Inadequate Encryption Strength vulnerability in LS ELECTRIC PLC and XG5000, a PLC programming software.
Titel
Softing Secure Integration Server
Veröffentlicht
16. August 2022 16:25
Text
This advisory contains mitigations for Out-of-bounds Read, Uncontrolled Search Path Element, Improper Authentication, Relative Path Traversal, Cleartext Transmission of Sensitive Information, NULL Pointer Dereference, and Integer Underflow vulnerabilities in various Softing products.
Titel
Delta Industrial Automation DRAS
Veröffentlicht
16. August 2022 16:25
Text
This advisory contains mitigations for an Improper Restriction of XML External Entity Reference vulnerability in Delta Industrial Automation DRAS, a controller software suite.
Titel
B&R Industrial Automation Automation Studio 4
Veröffentlicht
16. August 2022 16:15
Text
This advisory contains mitigations for an Unrestricted Upload of File with Dangerous Type vulnerability in Industrial Automation Automation Studio 4, a PLC automation programming software.
Titel
Emerson Proficy Machine Edition
Veröffentlicht
16. August 2022 16:10
Text
This advisory contains mitigations for Missing Support for Integrity Check, Improper Access Control, Unrestricted Upload of File with Dangerous Type, Improper Verification of Cryptographic Signature, Insufficient Verification of Data Authenticity, and Path Traversal: ‘\..\filename’ vulnerabilities in Emerson Proficy Machine Edition, an engineering workstation.
Titel
Sequi PortBloque S
Veröffentlicht
16. August 2022 16:05
Text
This advisory contains mitigations for Improper Authentication and Improper Authorization vulnerabilities in Sequi PortBloque S, a serial Modbus firewall.
Titel
Siemens Industrial Products with OPC UA (Update B)
Veröffentlicht
16. August 2022 16:00
Text
This updated advisory is a follow-up to the original advisory titled ICSA-22-132-08 Siemens Industrial Products with OPC UA (Update A) that was published May 12, 2022, on the ICS webpage on cisa.gov/ics. This advisory contains mitigations for various Siemens Industrial Products with OPC UA products.
Titel
AA22-223A: #StopRansomware: Zeppelin Ransomware
Veröffentlicht
11. August 2022 18:00
Text
Original release date: August 11, 2022SummaryActions to take today to mitigate cyber threats from ransomware: • Prioritize remediating known exploited vulnerabilities. • Train users to recognize and report phishing attempts. • Enable and enforce multifactor authentication. Note: this joint Cybersecurity Advisory (CSA) is part of an ongoing #StopRansomware effort to ...
Titel
Siemens Simcenter STAR-CCM+
Veröffentlicht
11. August 2022 16:54
Text
This advisory contains mitigations for an Exposure of Sensitive Information to an Unauthorized Actor vulnerability in versions of Siemens Simcenter STAR-CCM+ products.
Titel
Schneider Electric EcoStruxure, EcoStruxure Process Expert, SCADAPack RemoteConnect for x70
Veröffentlicht
11. August 2022 16:50
Text
This advisory contains mitigations for Heap-based Buffer Overflow, Wrap or Wraparound, Classic Buffer Overflow, and Out-of-bounds Write vulnerabilities in products using AT&T Labs Compressor (XMill) and Decompressor (XDemill).
Titel
Emerson ROC800, ROC800L and DL8000
Veröffentlicht
11. August 2022 16:48
Text
This advisory contains mitigations for an Insufficient Verification of Data Authenticity vulnerability in versions of ROC800, a remote automation controller.
Titel
Siemens SICAM A8000 Web Server Module
Veröffentlicht
11. August 2022 16:46
Text
This advisory contains mitigations for an Improper Access Control vulnerability in versions of SICAM A8000 Web Server Module products.
Titel
Siemens SICAM TOOLBOX II
Veröffentlicht
11. August 2022 16:44
Text
This advisory contains mitigations for a Use of Hard-coded Credentials vulnerability in versions of SICAM TOOLBOX II, a control and monitoring system.
Titel
Siemens SIMATIC S7-400 (Update A)
Veröffentlicht
11. August 2022 16:40
Text
This updated advisory is a follow-up to the advisory update titled ICSA-21-104-12 Siemens SIMATIC S7-400 that was published April 14, 2022, to the ICS webpage on www.cisa.gov/ics. This advisory contains mitigations for an Uncontrolled Resource Consumption vulnerability in the Siemens SIMATIC S7-400.
Titel
Siemens Industrial Products Intel CPUs (Update E)
Veröffentlicht
11. August 2022 16:38
Text
This updated advisory is a follow-up to the advisory update titled ICSA-21-222-05 Siemens Industrial Products Intel CPU (Update D) that was published July 14, 2022, to the ICS webpage on www.cisa.gov/ics. This advisory contains mitigations for a Missing Encryption of Sensitive Data vulnerability in versions of Siemens Industrial Products Intel ...
Titel
Siemens Industrial Products LLDP (Update C)
Veröffentlicht
11. August 2022 16:36
Text
This updated advisory is a follow-up to the original advisory titled ICSA-21-194-07 Siemens Industrial Products LLDP (Update B) that was published August 10, 2021, on the ICS webpage on cisa.gov/ics. This advisory contains mitigations for Classic Buffer Overflow and Uncontrolled Resource Consumption vulnerabilities in versions of Siemens Industrial Products (LLDP).
Titel
SafeLogic Designer vulnerabilities
Veröffentlicht
11. August 2022 02:00
Text

BOSCH-SA-463993: The SafeLogic Designer from Bosch Rexroth contains technology from SICK AG. The manufacturer has published a security bulletin regarding a vulnerability in the .NET framework. \[1\]A vulnerability in a .NET framework class used by SafeLogic Designer allows an attacker to craft malicious project files. Opening/importing such a malicious project ...

Titel
Mitsubishi Electric GT SoftGOT2000
Veröffentlicht
9. August 2022 16:15
Text
This advisory contains mitigations for Infinite Loop and OS Command Injection vulnerabilities in versions of Mitsubishi Electric GT SoftGOT2000 software.
Titel
Emerson ControlWave
Veröffentlicht
9. August 2022 16:10
Text
This advisory contains mitigations for an Insufficient Verification of Data Authenticity vulnerabilities in Emerson ControlWave products, a programmable controller.
Titel
Emerson OpenBSI
Veröffentlicht
9. August 2022 16:05
Text
This advisory contains mitigations for Use of Broken or Risky Cryptographic Algorithm and Use of Hard-coded Cryptographic Key vulnerabilities in Emerson OpenBSI, a set of network communication services.
Titel
SSA-220589 V1.2 (Last Update: 2022-08-09): Hard Coded Default Credential Vulnerability in Teamcenter
Veröffentlicht
9. August 2022 02:00
Text
Siemens has released updates for Teamcenter that fixes a security vulnerability related to unsecure storage of user credentials. This vulnerability affects Java EE Server Manager HTML Adaptor. This service is not installed by default and currently also obsoleted. Siemens has released updates for the affected products and recommends to update ...
Titel
SSA-629512 V1.6 (Last Update: 2022-08-09): Local Privilege Escalation Vulnerability in TIA Portal
Veröffentlicht
9. August 2022 02:00
Text
The latest updates for TIA Portal fix a vulnerability that could allow a local attacker to execute arbitrary code with SYSTEM privileges. Update: The previously provided fixes only correctly set the permissions on English Windows versions. Siemens has released updates for several affected products and recommends to update to the ...
Titel
SSA-446448 V1.3 (Last Update: 2022-08-09): Denial of Service Vulnerability in PROFINET Stack Integrated on Interniche Stack
Veröffentlicht
9. August 2022 02:00
Text
The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, contains a vulnerability that could allow an attacker to cause a denial of service condition on affected industrial products. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further ...

Letzte Updates

BOSCH PSIRT
21.08.2024
SIEMENS CERT
12.09.2024
US CERT
19.09.2024
US CERT (ICS)
19.09.2024

Nach Quelle

Archiv

2024
2023
2022
2021
2020
2019
2018
2017

Feeds