• 1
  • 2
  • 3 (current)
  • 4
  • 5
Montag, 10.02.2020
Titel
SSA-731239 (Last Update: 2020-02-10): Vulnerabilities in SIMATIC S7-300 and S7-400 CPUs
Veröffentlicht
10. Februar 2020 01:00
Text
Two vulnerabilities have been identified in SIMATIC S7-300 and S7-400 CPU families. One vulnerability could lead to a Denial-of-Service, the other vulnerability could result in credential disclosure. Siemens recommends specific mitigations. Siemens will update this advisory when new information becomes available.
Titel
SSA-954136 (Last Update: 2020-02-10): User Impersonation Vulnerability in SCALANCE X-200IRT Switch Family
Veröffentlicht
10. Februar 2020 01:00
Text
The latest firmware update for the SCALANCE X-200IRT switch family fixes a vulnerability which could allow attackers to impersonate legitimate users of the web interface.
Titel
SSA-818183 (Last Update: 2020-02-10): Denial-of-Service Vulnerability in SIMATIC S7-300 CPU Family
Veröffentlicht
10. Februar 2020 01:00
Text
Siemens has released a firmware update for the SIMATIC S7-300 CPU family which fixes a vulnerability that could allow remote attackers to perform a Denial-of-Service attack under certain conditions.
Titel
SSA-234763 (Last Update: 2020-02-10): OpenSSL Vulnerabilities in Siemens Industrial Products
Veröffentlicht
10. Februar 2020 01:00
Text
Vulnerabilities in OpenSSL (see https://www.openssl.org/news/secadv_20140605.txt) affect several Siemens industrial products. Siemens has released updates for all affected products.
Titel
SSA-306710 (Last Update: 2020-02-10): Denial-of-Service Vulnerability in SIMATIC S7-300 CPU Family
Veröffentlicht
10. Februar 2020 01:00
Text
Siemens has released a firmware update for the S7-300 CPU family which fixes a vulnerability that could allow remote attackers to perform a Denial-of-Service attack.
Titel
SSA-987029 (Last Update: 2020-02-10): Denial-of-Service Vulnerability in SIMATIC S7-300 CPU Family
Veröffentlicht
10. Februar 2020 01:00
Text
A vulnerability could allow attackers to perform a Denial-of-Service attack over the network without prior authentication against S7-300 CPUs under certain conditions. Siemens recommends specific mitigations. Siemens will update this advisory when new information becomes available.
Titel
SSA-180635 (Last Update: 2020-02-10): Denial-of-Service Vulnerabilities in SIMATIC S7-1500 CPU Family
Veröffentlicht
10. Februar 2020 01:00
Text
Older versions of the S7-1500 CPU are affected by two Denial-of-Service vulnerabilities. Siemens has released updates for the currently supported hardware versions.
Titel
SSA-804486 (Last Update: 2020-02-10): Multiple Vulnerabilities in SIMATIC Panels and SIMATIC WinCC (TIA Portal)
Veröffentlicht
10. Februar 2020 01:00
Text
The latest update for SIMATIC Panel Software and SIMATIC WinCC (TIA Portal) fixes two vulnerabilities. The most severe is a vulnerability which could allow an attacker with network access to the integrated device to read and write variables via SNMP. Siemens recommends to update to the newest version.
Titel
SSA-724606 (Last Update: 2020-02-10): Denial-of-Service Vulnerabilities in SIMATIC S7-1200 CPU Family
Veröffentlicht
10. Februar 2020 01:00
Text
Siemens SIMATIC S7-1200 PLCs, version 2 and higher, allow device management over TCP port 102 (ISO-TSAP) and retrieving status information over UDP port 161 (SNMP). It is possible to cause the device to go into defect mode by sending specially crafted packets to these ports. Siemens addresses these issues with ...
Titel
SSA-268644 (Last Update: 2020-02-10): Spectre-NG (Variants 3a and 4) Vulnerabilities in Industrial Products
Veröffentlicht
10. Februar 2020 01:00
Text
Security researchers published information on vulnerabilities known as Spectre-NG (Variants 3a and 4). These vulnerabilities affect many modern processors from different vendors to a varying degree. Several Industrial Products include affected processors and are affected by the vulnerabilities.
Titel
SSA-914382 (Last Update: 2020-02-10): Denial-of-Service Vulnerability in SIMATIC S7-400 CPU Family
Veröffentlicht
10. Februar 2020 01:00
Text
SIMATIC S7-400 CPUs are affected by a security vulnerability which could lead to a Denial-of-Service condition of the PLC if specially crafted packets are received and processed. The affected SIMATIC S7-400 CPU hardware versions are in the product cancellation phase or already phased-out. Siemens recommends customers either upgrading to a ...
Titel
SSA-321046 (Last Update: 2020-02-10): Denial-of-Service Vulnerability in SCALANCE X-300/X408 Switch Family
Veröffentlicht
10. Februar 2020 01:00
Text
The latest firmware update for the Siemens SCALANCE X-300 switch family and SCALANCE X 408 fixes two vulnerabilities. The vulnerabilities could allow attackers to cause a device reboot under certain conditions. An attacker must have network access to the device to exploit this vulnerability.
Titel
SSA-774850 (Last Update: 2020-02-10): Vulnerabilities in SIEMENS LOGO!8 devices
Veröffentlicht
10. Februar 2020 01:00
Text
Two vulnerabilities have been identified in SIEMENS LOGO!8 devices. The Session ID on the integrated webserver of LOGO!8 devices is not invalidated upon logout. The second vulnerability could allow an attacker with network access to port 10005/tcp to cause a Denial-of-Service condition by sending specifically crafted packages to the service. ...
Titel
SSA-944083 (Last Update: 2020-02-10): HTTP Header Injection in SIMATIC Panels and SIMATIC WinCC (TIA Portal)
Veröffentlicht
10. Februar 2020 01:00
Text
The latest update for SIMATIC Panel software and SIMATIC WinCC (TIA Portal) fixes a vulnerability that could allow an attacker with network access to the web server to perform a HTTP header injection attack.
Titel
SSA-176087 (Last Update: 2020-02-10): Unauthenticated Access to Critical Services in SCALANCE X-200 Switch Family
Veröffentlicht
10. Februar 2020 01:00
Text
A potential vulnerability was discovered in the web server authentication of SCALANCE X-200 and X-200IRT switches that might allow attackers to perform administrative operations over the network without authentication. This issue only applies to switches using older firmware versions and has been fixed from firmware V4.5.0 (non-IRT) and V5.1.0 (IRT) ...
Titel
SSA-279823 (Last Update: 2020-02-10): Cross-Site Scripting vulnerability in the SIMATIC S7-1200 CPU family
Veröffentlicht
10. Februar 2020 01:00
Text
Siemens SIMATIC S7-1200 CPUs, version 2 and higher, are capable of running an embedded web server. Web server functionality is disabled by default in the 1200 project configuration. However, if enabled, the web server is susceptible to Cross-Site Scripting (XSS). Siemens provides a firmware update which fixes this XSS vulnerability.
Titel
SSA-87240 (Last Update: 2020-02-10): Vulnerabilities in SIEMENS LOGO!
Veröffentlicht
10. Februar 2020 01:00
Text
Two vulnerabilities have been identified in SIEMENS LOGO!8 BM devices. The most severe vulnerability could allow an attacker to hijack existing web sessions. Siemens provides LOGO!8 BM FS-05 with firmware version V1.81.2, which fixes the first vulnerability, and recommends specific mitigations for the second vulnerability.
Titel
SSA-377318 (Last Update: 2020-02-10): Multiple vulnerabilities in Intel Active Management Technology (AMT) of SIMATIC IPCs
Veröffentlicht
10. Februar 2020 01:00
Text
There are multiple vulnerabilities in the Intel Management Engine used in multiple SIMATIC IPC devices that may allow arbitrary code execution, a partial denial of service or information disclosure. For additional information see: https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00141.html. Siemens provides updates for the affected devices.
Titel
SSA-240718 (Last Update: 2020-02-10): Insecure storage of HTTPS CA certificate in SIMATIC S7-1200 V2.x
Veröffentlicht
10. Februar 2020 01:00
Text
For the convenience of the customer, a Certificate Authority (CA) for HTTPS connections is installed on the Siemens SIMATIC S7-1200 PLC. The user has the option to trust this CA which if selected installs the certificate into the browser’s certificate store. Once the user completes this step, the browser will ...
Titel
SSA-447396 (Last Update: 2020-02-10): Denial-of-Service in SCALANCE X-300, SCALANCE X408 and SCALANCE X414
Veröffentlicht
10. Februar 2020 01:00
Text
A vulnerability has been identified in the integrated web server of SCALANCE X300, SCALANCE X408, and SCALANCE X414. The vulnerability could allow an attacker with network access to the device to cause a Denial-of-Service condition. The vulnerability can be triggered with publicly available tools, including vulnerability scanners. Siemens provides updates ...
Titel
SSA-994726 (Last Update: 2020-02-10): GHOST Vulnerability in Siemens Industrial Products
Veröffentlicht
10. Februar 2020 01:00
Text
The latest updates for the affected products fix the “GHOST” [1] vulnerability identified in glibc library (CVE-2015-0235). Incorrect parsing within the glibc library functions “gethostbyname()” and “gethostbyname2()” could cause a Denial-of-Service of the targeted system. [1] https://nvd.nist.gov/vuln/detail/CVE-2015-0235
Titel
SSA-507847 (Last Update: 2020-02-10): Cross-Site Request Forgery Vulnerability in SIMATIC S7-1200 CPU Family Version 4
Veröffentlicht
10. Februar 2020 01:00
Text
The latest firmware update for S7-1200 CPU family version 4 fixes a Cross-Site Request Forgery vulnerability. Siemens recommends to update affected devices as soon as possible.
Titel
SSA-635659 (Last Update: 2020-02-10): Heartbleed Vulnerability in Siemens Industrial Products
Veröffentlicht
10. Februar 2020 01:00
Text
The "Heartbleed" vulnerability in the OpenSSL cryptographic software library (CVE-2014-0160) affects several Siemens industrial products. Siemens has resolved the issue in all affected industrial products and provides updates which fix this vulnerability.
Titel
SSA-584286 (Last Update: 2020-02-10): Denial-of-Service Vulnerability in SIMATIC S7-1200 CPU and SIMATIC S7-1500 CPU
Veröffentlicht
10. Februar 2020 01:00
Text
A vulnerability was identified in SIMATIC S7-1200 and S7-1500 CPUs that could allow an attacker to cause a denial-of-service condition preventing HMI or engineering access to the PLC over port 102/tcp. Siemens has released an update for the S7-1500 product and recommends that customers update to the new version. Siemens ...
Titel
SSA-542701 (Last Update: 2020-02-10): Vulnerabilities in SIEMENS LOGO!
Veröffentlicht
10. Februar 2020 01:00
Text
Multiple vulnerabilities have been identified in SIEMENS LOGO!8 BM devices. The most severe vulnerability could lead to an attacker reading and modifying the device configuration if the attacker has access to port 10005/tcp.
  • 1
  • 2
  • 3 (current)
  • 4
  • 5

Letzte Updates

BOSCH PSIRT
31.10.2024
SIEMENS CERT
22.11.2024
US CERT
08.11.2024
US CERT (ICS)
21.11.2024

Nach Quelle

Archiv

2024
2023
2022
2021
2020
2019
2018
2017

Feeds