• 1
  • 2 (current)
Dienstag, 13.07.2021
Titel
SSA-729965 V1.0: TLS Certificate Validation Vulnerability in SINUMERIK Integrate Operate Client
Veröffentlicht
13. Juli 2021 02:00
Text
The latest update for SINUMERIK Integrate Operate Client fixes a vulnerability that could allow an attacker to spoof any SSL server certificate and conduct man-in-the-middle attacks. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available
Titel
SSA-772220 V1.0: OpenSSL Vulnerabilities in Industrial Products
Veröffentlicht
13. Juli 2021 02:00
Text
OpenSSL has published a security advisory [0] about a vulnerability in OpenSSL versions 1.1.1 < k, that allows an unauthenticated attacker to cause a Denial-of-Service (DoS) if a a maliciously crafted renegotiation message is sent. Siemens is preparing updates and recommends countermeasures for products where updates are not, or not ...
Titel
SSA-913875 V1.0: Frame Aggregation and Fragmentation Vulnerabilities in 802.11
Veröffentlicht
13. Juli 2021 02:00
Text
Twelve vulnerabilities in the implementation of frame aggregation and fragmentation of the 802.11 standard, under the name of FragAttacks, have been published. Successful exploitation of these vulnerabilities could allow an attacker within Wi-Fi range to forge encrypted frames, which could result in sensitive data disclosure and possibly traffic manipulation. The ...
Donnerstag, 01.07.2021
Titel
Sensormatic Electronics C-CURE 9000
Veröffentlicht
1. Juli 2021 16:20
Text
This advisory contains mitigations for an Improper Input Validation vulnerability in Sensormatic Electronics C-CURE 9000 industrial software.
Titel
Delta Electronics DOPSoft
Veröffentlicht
1. Juli 2021 16:15
Text
This advisory contains mitigations for Out-of-bounds Read vulnerabilities in Delta Electronics DOPSoft software.
Titel
Mitsubishi Electric Air Conditioning System
Veröffentlicht
1. Juli 2021 16:10
Text
This advisory contains mitigations for an Incorrect Implementation of Authentication Algorithm vulnerability in Mitsubishi Electric air conditioning systems.
Titel
Mitsubishi Electric Air Conditioning Systems
Veröffentlicht
1. Juli 2021 16:05
Text
This advisory contains mitigations for an Improper Restriction of XML External Entity Reference vulnerability in Mitsubishi Electric Air Conditioning Systems.
Titel
All Bachmann M1 System Processor Modules
Veröffentlicht
1. Juli 2021 16:00
Text
This updated advisory is a follow-up to the advisory titled ICSA-21-026-01P All Bachmann M1 System Processor Modules, posted to the HSIN ICS library on January 26, 2021. This advisory is now being released to the ICS webpage on us-cert.cisa.gov. This advisory contains mitigations for a Use of Password Hash with ...
  • 1
  • 2 (current)

Letzte Updates

BOSCH PSIRT
31.10.2024
SIEMENS CERT
22.11.2024
US CERT
08.11.2024
US CERT (ICS)
21.11.2024

Nach Quelle

Archiv

2024
2023
2022
2021
2020
2019
2018
2017

Feeds