• 1 (current)
  • 2
  • 3
Freitag, 28.04.2023
Titel
Use of Telnet in the interface module SLC-0-GPNT00300
Veröffentlicht
28. April 2023 02:00
Text

BOSCH-SA-387640: The SLC-0-GPNT00300 from Bosch Rexroth contains technology from SICK AG. The manufacturer has published a security bulletin \[1\] regarding the availability of a Telnet interface for debugging.The SLC-0-GPNT00300 provides a Telnet interface for debugging, which is enabled by factory default.\No password is set in the default configuration.\If the password ...

Mittwoch, 26.04.2023
Titel
Insecure authentication in B420 legacy communication module
Veröffentlicht
26. April 2023 02:00
Text

BOSCH-SA-341298-BT: An authentication vulnerability was found in the B420 Ethernet communication module from Bosch Security Systems. This is a legacy product which is currently obsolete and was announced to reach End on Life (EoL) on 2013. The B420 was last sold in July 2013 and was replaced by the B426. ...

Dienstag, 25.04.2023
Titel
Keysight N8844A Data Analytics Web Service
Veröffentlicht
25. April 2023 14:00
Text
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Keysight Equipment: N8844A Data Analytics Web Service Vulnerability: Deserialization of Untrusted Data 2. RISK EVALUATION Successful exploitation of this vulnerability could lead to remote code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Keysight reports this vulnerability affects the ...
Titel
Scada-LTS Third Party Component
Veröffentlicht
25. April 2023 14:00
Text
1. EXECUTIVE SUMMARY CVSS v3 6.5 ATTENTION: Exploitable remotely/low attack complexity/public exploits are available Vendor: Scada-LTS Equipment: Scada-LTS Vulnerability: Cross-site Scripting 2. RISK EVALUATION Successful exploitation of this vulnerability could allow loss of sensitive information and execution of arbitrary code. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of ...
Donnerstag, 20.04.2023
Titel
INEA ME RTU
Veröffentlicht
20. April 2023 14:00
Text
1. EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: INEA Equipment: ME RTU Vulnerability: OS Command Injection 2. RISK EVALUATION Successful exploitation of this vulnerability could allow remote code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of ME RTU, a remote terminal unit, are ...
Dienstag, 18.04.2023
Titel
Omron CS/CJ Series
Veröffentlicht
18. April 2023 14:00
Text
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Omron Equipment: SYSMAC CS/CJ Series Vulnerability: Missing Authentication for Critical Function 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to access sensitive information in the file system and memory. 3. TECHNICAL DETAILS 3.1 AFFECTED ...
Titel
Schneider Electric Easy UPS Online Monitoring Software
Veröffentlicht
18. April 2023 14:00
Text
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: APC Easy UPS Online Monitoring Software, Schneider Electric Easy UPS Online Monitoring Software Vulnerabilities: Missing Authentication for Critical Function, Improper Handling of Case Sensitivity 2. RISK EVALUATION Successful exploitation of these vulnerabilities could result in ...
Montag, 17.04.2023
Titel
APT28 Exploits Known Vulnerability to Carry Out Reconnaissance and Deploy Malware on Cisco Routers
Veröffentlicht
17. April 2023 22:32
Text
APT28 accesses poorly maintained Cisco routers and deploys malware on unpatched devices using CVE-2017-6742. Overview and Context The UK National Cyber Security Centre (NCSC), the US National Security Agency (NSA), US Cybersecurity and Infrastructure Security Agency (CISA) and US Federal Bureau of Investigation (FBI) are releasing this joint advisory to ...
Donnerstag, 13.04.2023
Titel
Siemens CPCI85 Firmware of SICAM A8000 Devices
Veröffentlicht
13. April 2023 14:00
Text
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). 1. EXECUTIVE SUMMARY CVSS v3 ...
Titel
Siemens SCALANCE XCM332
Veröffentlicht
13. April 2023 14:00
Text
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). 1. EXECUTIVE SUMMARY CVSS v3 ...
Titel
Siemens JT Open and JT Utilities
Veröffentlicht
13. April 2023 14:00
Text
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). 1. EXECUTIVE SUMMARY CVSS v3 ...
Titel
Siemens Path Traversal TIA Portal
Veröffentlicht
13. April 2023 14:00
Text
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). 1. EXECUTIVE SUMMARY CVSS v3 ...
Titel
Siemens SCALANCE X-200, X-200IRT, and X-300 Switch Families BadAlloc Vulnerabilities
Veröffentlicht
13. April 2023 14:00
Text
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). 1. EXECUTIVE SUMMARY CVSS v3 ...
Titel
Mitsubishi Electric India GC-ENET-COM
Veröffentlicht
13. April 2023 14:00
Text
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Mitsubishi Electric India Equipment: GC-ENET-COM Vulnerability: Signal Handler Race Condition 2. RISK EVALUATION Successful exploitation of this vulnerability could lead to a communication error and may result in a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The ...
Titel
Siemens Adaptec maxView Application
Veröffentlicht
13. April 2023 14:00
Text
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). 1. EXECUTIVE SUMMARY CVSS v3 ...
Dienstag, 11.04.2023
Titel
FANUC ROBOGUIDE-HandlingPRO
Veröffentlicht
11. April 2023 14:00
Text
1. EXECUTIVE SUMMARY CVSS v3 6.8 ATTENTION: Exploitable remotely Vendor: FANUC Equipment: ROBOGUIDE-HandlingPRO Vulnerability: Path Traversal 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to read and/or overwrite files on the system running the affected software. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of ...
Titel
SSA-780073 V2.3 (Last Update: 2023-04-11): Denial of Service Vulnerability in PROFINET Devices via DCE-RPC Packets
Veröffentlicht
11. April 2023 02:00
Text
Products that include the Siemens PROFINET-IO (PNIO) stack in versions prior V06.00 are potentially affected by a denial of service vulnerability when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens ...
Titel
SSA-787941 V1.2 (Last Update: 2023-04-11): Denial of Service Vulnerability in RUGGEDCOM ROS V4
Veröffentlicht
11. April 2023 02:00
Text
RUGGEDCOM ROS-based V4 devices are vulnerable to a denial of service attack (Slowloris). By sending partial HTTP requests nonstop, with none completed, the affected web servers will be waiting for the completion of each request, occupying all available HTTP connections. The web server recovers by itself once the attack ends. ...
Titel
SSA-978220 V1.8 (Last Update: 2023-04-11): Denial of Service Vulnerability over SNMP in Multiple Industrial Products
Veröffentlicht
11. April 2023 02:00
Text
Several industrial products are affected by a vulnerability that could allow remote attackers to conduct a denial of service attack by sending specially crafted packets to port 161/udp (SNMP). Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for ...
Titel
SSA-792594 V1.1 (Last Update: 2023-04-11): Host Header Injection Vulnerability in Polarion ALM
Veröffentlicht
11. April 2023 02:00
Text
Polarion ALM contains a misconfiguration in its default Apache HTTP Server configuration that could allow an attacker to perform host header injection attacks. Siemens has released an update for Polarion ALM and recommends to update to the latest version.
Titel
SSA-632164 V1.0: External Entity Injection Vulnerability in Polarion ALM
Veröffentlicht
11. April 2023 02:00
Text
Polarion ALM is vulnerable to XML External Entity (XXE) injection attack that could allow an attacker to potentially disclose confidential data. Siemens has released an update for Polarion ALM and recommends to update to the latest version, and update specific configurations to mitigate against the vulnerability. The configuration changes to ...
Titel
SSA-813746 V1.0: BadAlloc Vulnerabilities in SCALANCE X-200, X-200IRT, and X-300 Switch Families
Veröffentlicht
11. April 2023 02:00
Text
Siemens has released a new firmware version for SCALANCE X-200 and X-200 IRT switches that address Bad Alloc vulnerabilities in the underlying operating system and recommends to update to the latest versions. Siemens recommends countermeasures for products where updates are not, or not yet available.
Titel
SSA-566905 V1.0: Multiple Denial of Service Vulnerabilities in the Webserver of Industrial Products
Veröffentlicht
11. April 2023 02:00
Text
Multiple vulnerabilities in the affected products could allow an unauthorized attacker with network access to the webserver of an affected products to perform a denial of service attack. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and ...
Titel
SSA-629917 V1.0: Datalogics File Parsing Vulnerability in Teamcenter Visualization and JT2Go
Veröffentlicht
11. April 2023 02:00
Text
Siemens Teamcenter Visualization and JT2Go are affected by a memory corruption vulnerability in the APDFL library from Datalogics. If a user is tricked to open a malicious PDF file with the affected products, this could lead the application to crash or potentially lead to arbitrary code execution. Siemens has released ...
Titel
SSA-642810 V1.0: JT File Parsing Vulnerability in JT Open and JT Utilities
Veröffentlicht
11. April 2023 02:00
Text
JT Open Toolkit and JT Utilities are affected by a memory corruption vulnerability that could be triggered while parsing JT files. If a user is tricked to open a malicious JT file with any of the affected products, this could cause the application to crash or potentially lead to arbitrary ...
  • 1 (current)
  • 2
  • 3

Letzte Updates

BOSCH PSIRT
31.10.2024
SIEMENS CERT
22.11.2024
US CERT
08.11.2024
US CERT (ICS)
21.11.2024

Nach Quelle

Archiv

2024
2023
2022
2021
2020
2019
2018
2017

Feeds