• 1
  • 2 (current)
  • 3
Dienstag, 11.06.2024
Titel
SSA-035466 V1.1 (Last Update: 2024-06-11): Incorrect Permission Assignment in SICAM PAS/PQS
Veröffentlicht
11. Juni 2024 02:00
Text
SICAM PAS/PQS is affected by insecure permission assignments in application folders that could allow an authenticated local attacker to read and modify configuration data or to escalate privileges. Siemens has released a new version for SICAM PAS/PQS and recommends to update to the latest version. Siemens has also released a ...
Titel
SSA-024584 V1.0: Authentication Bypass Vulnerability in PowerSys before V3.11
Veröffentlicht
11. Juni 2024 02:00
Text
PowerSys before V3.11 is affected by a vulnerability that could allow a local attacker to bypass authentication, thereby gaining administrative privileges for the managed remote devices. Siemens has released a new version for PowerSys and recommends to update to the latest version.
Titel
SSA-319319 V1.0: Denial of Service Vulnerability in TIA Administrator
Veröffentlicht
11. Juni 2024 02:00
Text
TIA Administrator creates temporary download files in a directory with insecure permissions. This could allow any authenticated attacker on Windows to disrupt the update process. Siemens has released a new version for TIA Administrator and recommends to update to the latest version.
Titel
SSA-900277 V1.0: MODEL File Parsing Vulnerability in Tecnomatix Plant Simulation before V2302.0012 and V2024.0001
Veröffentlicht
11. Juni 2024 02:00
Text
Tecnomatix Plant Simulation contains a type confusion vulnerability that could be triggered when the application reads MODEL files. If a user is tricked to open a malicious file using the affected application, this could lead to a crash, and potentially also to arbitrary code execution on the target host system. ...
Titel
SSA-879734 V1.0: Multiple Vulnerabilities in SCALANCE XM-400/XR-500 before V6.6.1
Veröffentlicht
11. Juni 2024 02:00
Text
Siemens has released new versions for the affected products and recommends to update to the latest versions.
Titel
SSA-238730 V1.0: Out-of-Bounds Write Vulnerabilities in SITOP UPS1600 before V2.5.4
Veröffentlicht
11. Juni 2024 02:00
Text
Multiple out-of-bounds vulnerabilities in third-party components are affecting SITOP UPS1600 before V2.5.4. Attackers could exploit these vulnerabilities and cause limited impact in the affected systems. Siemens has released new versions for the affected products and recommends to update to the latest versions.
Titel
SSA-871704 V1.1 (Last Update: 2024-06-11): Multiple Vulnerabilities in SICAM Products
Veröffentlicht
11. Juni 2024 02:00
Text
Multiple SICAM products are affected by vulnerabilities that could lead to privilege escalation, remote code execution or information loss namely: SICAM A8000 device firmwares CPC80 for CP-8000/CP-8021/CP-8022 CPCI85 and OPUPI0 for CP-8031/CP-8050 SICAM EGS firmware CPCI85 and OPUPI0 SICAM 8 Software Solution SICORE Siemens has released new versions for the ...
Titel
SSA-832273 V1.3 (Last Update: 2024-06-11): Multiple Vulnerabilities in Fortigate NGFW before V7.4.3 on RUGGEDCOM APE1808 devices
Veröffentlicht
11. Juni 2024 02:00
Text
Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available. Siemens recommends to consult and implement the workarounds provided in Fortinet’s upstream security notifications.
Titel
SSA-771940 V1.0: X_T File Parsing Vulnerabilities in Teamcenter Visualization and JT2Go
Veröffentlicht
11. Juni 2024 02:00
Text
Teamcenter Visualization and JT2Go is affected by out of bounds read, stack exhaustion and null pointer dereference vulnerabilities that could be triggered when the application reads files in X_T format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the vulnerability ...
Titel
SSA-753746 V1.2 (Last Update: 2024-06-11): Denial of Service Vulnerabilities in SIMATIC WinCC Affecting Other SIMATIC Software Products
Veröffentlicht
11. Juni 2024 02:00
Text
Two null point dereference vulnerabilities affect multiple SIMATIC software products. These could allow an attacker to cause a persistent denial of service condition in the RPC Server of these products. Siemens has released new versions for the affected products and recommends to update to the latest versions.
Titel
SSA-711309 V1.9 (Last Update: 2024-06-11): Denial of Service Vulnerability in the OPC UA Implementations of SIMATIC Products
Veröffentlicht
11. Juni 2024 02:00
Text
The OPC UA implementations (ANSI C and C++) as used in several SIMATIC products contain a denial of service vulnerability that could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate. Siemens has released new versions for several affected products and ...
Titel
SSA-690517 V1.0: Multiple Vulnerabilities in SCALANCE W700 802.11 AX Family
Veröffentlicht
11. Juni 2024 02:00
Text
SCALANCE W700 802.11 AX Family is affected by multiple vulnerabilities. Siemens recommends countermeasures for products where fixes are not, or not yet available.
Titel
SSA-625862 V1.0: Multiple Vulnerabilities in Third-Party Components in SIMATIC CP 1542SP-1 and CP 1543SP-1 before V2.3
Veröffentlicht
11. Juni 2024 02:00
Text
SIMATIC CP 1542SP-1 and CP 1543SP-1 before V2.3 are affected by multiple vulnerabilities in third-party components and the integrated web server. Siemens has released new versions for the affected products and recommends to update to the latest versions.
Titel
SSA-620338 V1.0: Buffer Overflow Vulnerability in SICAM AK3 / BC / TM
Veröffentlicht
11. Juni 2024 02:00
Text
SICAM AK3/TM/BC devices are affected by a buffer overflow vulnerability that could allow an attacker to execute code in the context of the current process or lead to a denial of service condition. SICAM AK3 device firmware CPCX26 for CP-2016 PCCX26 for CP-2019 SICAM AK3, SICAM BC and SICAM TM ...
Titel
SSA-599968 V1.6 (Last Update: 2024-06-11): Denial-of-Service Vulnerability in Profinet Devices
Veröffentlicht
11. Juni 2024 02:00
Text
A vulnerability in affected devices could allow an attacker to perform a denial-of-service attack if a large amount of Profinet Discovery and Configuration Protocol (DCP) reset packets is sent to the affected devices. Siemens has released new versions for several affected products and recommends to update to the latest versions. ...
Titel
SSA-566905 V1.2 (Last Update: 2024-06-11): Multiple Denial of Service Vulnerabilities in the Webserver of Industrial Products
Veröffentlicht
11. Juni 2024 02:00
Text
Multiple vulnerabilities in the affected products could allow an unauthorized attacker with network access to the webserver of an affected products to perform a denial of service attack. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix ...
Titel
SSA-540640 V1.0: Improper Privilege Management Vulnerability in Mendix Runtime
Veröffentlicht
11. Juni 2024 02:00
Text
Apps built with Mendix Runtime >= V9.3 could allow users with the capability to manage a role to elevate the access rights of users with that role. Successful exploitation requires to guess the id of a target role which contains the elevated access rights. Siemens has released new versions for ...
Titel
SSA-482757 V1.4 (Last Update: 2024-06-11): Missing Immutable Root of Trust in S7-1500 CPU devices
Veröffentlicht
11. Juni 2024 02:00
Text
Affected models of the S7-1500 CPU product family do not contain an Immutable Root of Trust in Hardware. With this the integrity of the code executed on the device can not be validated during load-time. An attacker with physical access to the device could use this to replace the boot ...
Titel
SSA-481506 V1.0: Information Disclosure Vulnerability in SIMATIC S7-200 SMART Devices
Veröffentlicht
11. Juni 2024 02:00
Text
SIMATIC S7-200 SMART devices contain an information disclosure vulnerability which leaves the system susceptible to a family of attacks which rely on the use of predictable IP ID sequence numbers as their base method of attack and eventually could allow an attacker to create a denial of service condition. Siemens ...
Titel
SSA-446448 V2.1 (Last Update: 2024-06-11): Denial of Service Vulnerability in PROFINET Stack Integrated on Interniche Stack
Veröffentlicht
11. Juni 2024 02:00
Text
The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, contains a vulnerability that could allow an attacker to cause a denial of service condition on affected industrial products. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing ...
Titel
SSA-407785 V1.2 (Last Update: 2024-06-11): Multiple X_T File Parsing Vulnerabilities in Parasolid and Teamcenter Visualization
Veröffentlicht
11. Juni 2024 02:00
Text
Parasolid and Teamcenter Visualization are affected by memory corruption vulnerabilities that could be triggered when the application reads files in X_T format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the vulnerability to perform remote code execution or denial of ...
Titel
SSA-398330 V1.6 (Last Update: 2024-06-11): Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP V3.1
Veröffentlicht
11. Juni 2024 02:00
Text
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version V3.1 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not ...
Titel
SSA-353002 V1.1 (Last Update: 2024-06-11): Multiple Vulnerabilities in SCALANCE XB-200 / XC-200 / XP-200 / XF-200BA / XR-300WG Family
Veröffentlicht
11. Juni 2024 02:00
Text
SCALANCE XB-200/XC-200/XP-200/XF-200BA/XR-300WG Family is affected by multiple vulnerabilities. CVE-2023-44318 and CVE-2023-44321 were previously published as part of SSA-699386. Siemens recommends countermeasures for products where fixes are not, or not yet available.
Titel
SSA-341067 V1.0: Multiple vulnerabilities in third-party components in ST7 ScadaConnect before V1.1
Veröffentlicht
11. Juni 2024 02:00
Text
Siemens has released a new version for ST7 ScadaConnect and recommends to update to the latest version.
Donnerstag, 06.06.2024
Titel
Emerson Ovation
Veröffentlicht
6. Juni 2024 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Emerson Equipment: Ovation Vulnerabilities: Missing Authentication for Critical Function, Insufficient Verification of Data Authenticity CISA is aware of a public report, known as "OT:ICEFALL", detailing vulnerabilities found in multiple operational technology (OT) vendors. CISA is issuing ...