• 1
  • 2 (current)
  • 3
Dienstag, 10.09.2024
Titel
SSA-423808 V1.0: Multiple NULL Pointer Dereference Vulnerabilities in Industrial Products
Veröffentlicht
10. September 2024 02:00
Text
Multiple NULL pointer dereference vulnerabilities in the affected products could allow an attacker with network access to the webserver, to perform a denial of service attack. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where ...
Titel
SSA-359713 V1.0: Authorization Bypass Vulnerability in Industrial Edge Management
Veröffentlicht
10. September 2024 02:00
Text
Industrial Edge Management contains an Authorization Bypass vulnerability that could allow an unauthenticated remote attacker to impersonate other devices onboarded to the system. Siemens has released new versions for the affected products and recommends to update to the latest versions.
Titel
SSA-349422 V2.1 (Last Update: 2024-09-10): Denial of Service Vulnerability in Industrial Real-Time (IRT) Devices
Veröffentlicht
10. September 2024 02:00
Text
A vulnerability in the affected products could allow an unauthorized attacker with network access to perform a denial-of-service attack resulting in loss of real-time synchronization. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where updates are ...
Titel
SSA-342438 V1.0: Privilege Escalation Vulnerability in SINUMERIK ONE, SINUMERIK 840D and SINUMERIK 828D
Veröffentlicht
10. September 2024 02:00
Text
SINUMERIK ONE, SINUMERIK 840D sl and SINUMERIK 828D are affected by a privilege escalation vulnerability that could allow an authenticated local attacker to escalate their privileges in the underlying system. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures ...
Titel
SSA-293562 V3.6 (Last Update: 2024-09-10): Denial of Service Vulnerabilities in PROFINET DCP Implementation of Industrial Products
Veröffentlicht
10. September 2024 02:00
Text
Several industrial devices are affected by two vulnerabilities that could allow an attacker to cause a denial of service condition via PROFINET DCP network packets under certain circumstances. The precondition for this scenario is a direct layer 2 access to the affected products. PROFIBUS interfaces are not affected. Siemens has ...
Titel
SSA-280603 V1.1 (Last Update: 2024-09-10): Denial of Service Vulnerability in SINUMERIK ONE and SINUMERIK MC
Veröffentlicht
10. September 2024 02:00
Text
A vulnerability has been identified in the integrated S7-1500 CPU of SINUMERIK ONE and SINUMERIK MC products that could allow an attacker to cause a denial of service condition. In order to exploit the vulnerability, an attacker must have access to the affected devices on port 102/tcp. Siemens is preparing ...
Titel
SSA-103653 V1.0: Denial-of-Service Vulnerability in Automation License Manager
Veröffentlicht
10. September 2024 02:00
Text
A vulnerability was identified in the Automation License Manager software that could be triggered by sending specially crafted packets to port 4410/tcp of an affected system. This could cause a denial-of-service preventing legitimate users from using the system. Siemens has released a new version for Automation License Manager V6.2 and ...
Titel
SSA-097786 V1.0: Insertion of Sensitive Information into Log File Vulnerability in SINUMERIK systems
Veröffentlicht
10. September 2024 02:00
Text
SINUMERIK systems, that have been provisioned with Create MyConfig (CMC), are affected by a Insertion of Sensitive Information into Log File vulnerability. When using a CMC package on a NCU or on an IPC the password used in the CMC package or typed in manually during package execution is traced ...
Titel
SSA-097435 V1.0: Usernames Disclosure Vulnerability in Mendix Runtime
Veröffentlicht
10. September 2024 02:00
Text
Mendix Runtime contains an observable response discrepancy vulnerability when validating usernames during authentication. This could allow unauthenticated remote attackers to distinguish between valid and invalid usernames. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and ...
Titel
SSA-088132 V1.1 (Last Update: 2024-09-10): Denial of Service Vulnerability in the OPC UA Server Implementations of Several Industrial Products
Veröffentlicht
10. September 2024 02:00
Text
Unified Automation .NET based OPC UA Server SDK before 3.2.2 used in several industrial products are affected by a similar vulnerability as documented in CVE-2023-27321 for the OPC Foundation UA .NET Standard implementation. A successful attack may lead to high load situation and memory exhaustion, and may block the OPC ...
Titel
SSA-039007 V1.0: Heap-based Buffer Overflow Vulnerability in User Management Component (UMC)
Veröffentlicht
10. September 2024 02:00
Text
Siemens User Management Component (UMC) is affected by a heap-based buffer overflow vulnerability which could allow an unauthenticated remote attacker arbitrary code execution. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures ...
Titel
SSA-417159 V1.0: Multiple Vulnerabilities in SINEMA Remote Connect Client Before V3.2 SP2
Veröffentlicht
10. September 2024 02:00
Text
SINEMA Remote Connect Client before V3.2 SP2 is affected by multiple vulnerabilities. Siemens has released a new version for SINEMA Remote Connect Client and recommends to update to the latest version.
Titel
SSA-969738 V1.0: Denial of Service Vulnerability in SIMATIC S7-200 SMART Devices
Veröffentlicht
10. September 2024 02:00
Text
A vulnerability in SIMATIC S7-200 SMART devices could allow an attacker to cause a denial of service condition if a specially crafted TCP packet is sent to the device. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.
Titel
SSA-962515 V1.2 (Last Update: 2024-09-10): Out of Bounds Read Vulnerability in Industrial Products
Veröffentlicht
10. September 2024 02:00
Text
Several industrial products contain an out of bounds read vulnerability that could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel, leading to denial of service condition. Siemens has released new versions for several affected products and recommends to update to the ...
Titel
SSA-999588 V1.5 (Last Update: 2024-09-10): Multiple Vulnerabilities in User Management Component (UMC) Before V2.11.2
Veröffentlicht
10. September 2024 02:00
Text
Siemens User Management Component (UMC) before V2.11.2 is affected by multiple vulnerabilities where the most severe could lead to a restart of the UMC server. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes ...
Titel
SSA-955858 V1.2 (Last Update: 2024-09-10): Multiple Vulnerabilities in LOGO! 8 BM Devices
Veröffentlicht
10. September 2024 02:00
Text
LOGO! 8 BM (incl. SIPLUS variants) contains multiple web-related vulnerabilities. These could allow an attacker to execute code remotely, put the device into a denial of service state or retrieve parts of the memory. The vulnerabilities are related to the hardware of the product. Siemens has released new hardware versions ...
Titel
SSA-921449 V1.1 (Last Update: 2024-09-10): Plaintext Storage of a Password Vulnerability in LOGO! V8.3 BM Devices
Veröffentlicht
10. September 2024 02:00
Text
LOGO! V8.3 BM (incl. SIPLUS variants) devices contain a plaintext storage of a password vulnerability. This could allow an attacker with phyiscal access to an affected device to extract user-set passwords from an embedded storage IC. Siemens has released new hardware versions with the LOGO! V8.4 BM and the SIPLUS ...
Titel
SSA-883918 V1.1 (Last Update: 2024-09-10): Information Disclosure Vulnerability in SIMATIC WinCC
Veröffentlicht
10. September 2024 02:00
Text
Multiple versions of SIMATIC WinCC and SIMATIC PCS 7 do not properly handle certain requests to their web application (WinCC WebNavigator, PCS 7 Web Server, and PCS 7 Web Diagnostics Server), which may lead to the leak of privileged information. This could allow an unauthenticated remote attacker to retrieve information ...
Titel
SSA-869574 V1.0: Multiple Vulnerabilities in SINEMA Remote Connect Server Before V3.2 SP2
Veröffentlicht
10. September 2024 02:00
Text
SINEMA Remote Connect Server before V3.2 SP2 is affected by multiple vulnerabilities. Siemens has released a new version for SINEMA Remote Connect Client and recommends to update to the latest version.
Titel
SSA-844582 V1.1 (Last Update: 2024-09-10): Electromagnetic Fault Injection in LOGO! V8.3 BM Devices Results in Broken LOGO! V8.3 Product CA
Veröffentlicht
10. September 2024 02:00
Text
LOGO! V8.3 BM (incl. SIPLUS variants) devices contain a vulnerability that could allow an electromagnetic fault injection. This could allow an attacker to dump and debug the firmware, including the manipulation of memory. Further actions could allow to inject public keys of custom created key pairs which are then signed ...
Titel
SSA-832273 V1.5 (Last Update: 2024-09-10): Multiple Vulnerabilities in Fortigate NGFW Before V7.4.3 on RUGGEDCOM APE1808 Devices
Veröffentlicht
10. September 2024 02:00
Text
Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products. Siemens has released a new version of Fortigate NGFW for RUGGEDCOM APE1808 and recommends to update to the latest version. Siemens recommends to consult and implement the workarounds provided in Fortinet’s upstream security notifications.
Titel
SSA-792319 V1.1 (Last Update: 2024-09-10): Missing Read Out Protection in SENTRON 7KM PAC3x20 Devices
Veröffentlicht
10. September 2024 02:00
Text
The read out protection of the internal flash of affected devices was not properly set at the end of the manufacturing process. An attacker with physical access to the device could read out the data. Siemens has released new versions for the affected products and recommends to update to the ...
Titel
SSA-783481 V1.2 (Last Update: 2024-09-10): Denial-of-Service Vulnerability in LOGO! 8 BM
Veröffentlicht
10. September 2024 02:00
Text
A Denial-of-Service vulnerability has been identified in LOGO! 8 BM. This vulnerability could allow an attacker to crash a device, if a user is tricked into loading a malicious project file onto an affected device. The vulnerability is related to the hardware of the product. Siemens has released new hardware ...
Titel
SSA-773256 V1.0: Impact of Socket.IO CVE-2024-38355 on Siemens Industrial Products
Veröffentlicht
10. September 2024 02:00
Text
A Socket.IO vulnerability affects multiple Siemens industrial products. This vulnerability consists of a specially crafted Socket.IO packet that triggers an uncaught exception on the Socket.IO server killing the Node.js process allowing a remote attacker to cause Denial-of-Service condition in the affected products. Siemens has released new versions for several affected ...
Titel
SSA-765405 V1.0: Multiple Vulnerabilities in SIMATIC RFID Readers
Veröffentlicht
10. September 2024 02:00
Text
SIMATIC RFID Readers contain multiple vulnerabilities that could allow an attacker to cause Denial-of-Service, exploit hidden functionality and information exposure. Siemens has released new versions for the affected products and recommends to update to the latest versions.