As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY ...
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 4.9 ATTENTION: Low attack complexity Vendor: Hitachi Energy Equipment: FOX61x, FOXCST, FOXMAN-UN Vulnerability: Improper Validation of Certificate with Host Mismatch 2. RISK EVALUATION Successful exploitation of this vulnerability could allow attackers to intercept or falsify data exchanges between the client and the server. ...
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 4.9 ATTENTION: Exploitable remotely/low attack complexity Vendor: Hitachi Energy Equipment: FOX61x Products Vulnerability: Relative Path Traversal 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to traverse the file system to access files or directories that would otherwise be inaccessible. ...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY ...
BOSCH-SA-904062-BT: An unquoted service path enumeration vulnerability on SMCWatchDog agent has been found affecting the DIVAR IP all-in-one 7000 (DIP-72xx) devices. This vulnerability can allow a local attacker to gain elevated privileges.
Several camera device drivers in the Siveillance Video Device Pack store camera credentials in their log file when authentication fails. This could allow a local attacker to read camera credentials stored in the Recording Server under specific conditions. Siemens has released an update of the Device Pack and recommends to ...
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low Attack Complexity Vendor: Schneider Electric Equipment: Vijeo Designer Vulnerability: Improper Privilege Management 2. RISK EVALUATION Successful exploitation of these vulnerabilities could cause a non-admin authenticated user to perform privilege escalation by tampering with the binaries. 3. TECHNICAL DETAILS 3.1 AFFECTED ...
SCALANCE W-700 IEEE 802.11ax family devices are affected by multiple vulnerabilities. Siemens has released a new version for SCALANCE W-700 IEEE 802.11ax family and recommends to update to the latest version. Siemens recommends countermeasures for vulnerabilities where fixes are not, or not yet available.
The products listed below contain a remote code execution vulnerability that could allow an authenticated remote attacker to execute arbitrary code with high privileges. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures for products where fixes are not, ...
A vulnerability exists in affected products that could allow remote attackers to affect the availability of the devices under certain conditions. The underlying TCP stack can be forced to make very computation expensive calls for every incoming packet which can lead to a Denial-of-Service. Siemens has released new versions for ...
Affected models of the S7-1500 CPU product family do not contain an Immutable Root of Trust in Hardware. With this the integrity of the code executed on the device can not be validated during load-time. An attacker with physical access to the device could use this to replace the boot ...
The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, contains a vulnerability that could allow an attacker to cause a denial of service condition on affected industrial products. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific ...
Multiple SCALANCE devices are affected by several vulnerabilities that could allow an attacker to inject code, retrieve data as debug information as well as user CLI passwords or set the CLI to an irresponsive state. Siemens has released updates for the affected products and recommends to update to the latest ...
Several HikVision camera device drivers in the Siveillance Video Device Pack store camera credentials in their log file when authentication fails. This could allow a local attacker to read camera credentials stored in the Recording Server under specific conditions. Siemens has released an update of the Device Pack and recommends ...
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version V3.1 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not ...
The Mendix LDAP module is affected by an LDAP injection vulnerability that could allow an unauthenticated remote attacker to bypass username verification. Siemens has released a new version for Mendix LDAP and recommends to update to the latest version.
Affected SIPROTEC 5 devices do not properly limit the access of the web server to the filesystem. This could allow an authenticated remote attacker to read arbitrary files or the entire filesystem of the device. Siemens has released new versions for several affected products and recommends to update to the ...
Mendix Runtime contains an observable response discrepancy vulnerability when validating usernames during authentication. This could allow unauthenticated remote attackers to distinguish between valid and invalid usernames. Siemens has released new versions for the affected products and recommends to update to the latest versions.
Several SIMATIC S7-1500 CPU versions are affected by an authentication bypass vulnerability that could allow an unauthenticated remote attacker to gain knowledge about actual and configured maximum cycle times and communication load of the CPU. Siemens has released new versions for several affected products and recommends to update to the ...
Siemens User Management Component (UMC) is affected by a heap-based buffer overflow vulnerability which could allow an unauthenticated remote attacker arbitrary code execution. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures ...
Industrial Edge Management is affected by a reflected cross-site scripting (XSS) vulnerability that could allow an attacker to extract sensitive information by tricking users into accessing a malicious link. Siemens recommends countermeasures for products where fixes are not, or not yet available.
Siemens User Management Component (UMC) before V2.11.2 is affected by multiple vulnerabilities where the most severe could lead to a restart of the UMC server. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes ...
Several SIMATIC S7-1500 and S7-1200 CPU versions are affected by an open redirect vulnerability that could allow an attacker to make the web server of affected devices redirect a legitimate user to an attacker-chosen URL. For a successful attack, the legitimate user must actively click on an attacker-crafted link. Siemens ...