• 1
  • 2 (current)
Dienstag, 14.01.2025
Titel
SSA-871035 V1.1 (Last Update: 2025-01-14): Session-Memory Deserialization Vulnerability in Siemens Engineering Platforms Before V19
Veröffentlicht
14. Januar 2025 01:00
Text
Affected products do not properly sanitize user-controllable input when parsing files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures for ...
Titel
SSA-773256 V1.3 (Last Update: 2025-01-14): Impact of Socket.IO CVE-2024-38355 on Siemens Industrial Products
Veröffentlicht
14. Januar 2025 01:00
Text
A Socket.IO vulnerability affects multiple Siemens industrial products. This vulnerability consists of a specially crafted Socket.IO packet that triggers an uncaught exception on the Socket.IO server killing the Node.js process allowing a remote attacker to cause Denial-of-Service condition in the affected products. Siemens has released new versions for several affected ...
Titel
SSA-730482 V1.2 (Last Update: 2025-01-14): Denial of Service Vulnerability in SIMATIC WinCC
Veröffentlicht
14. Januar 2025 01:00
Text
A vulnerability in the login dialog box of SIMATIC WinCC could allow a local attacker to cause a denial of service condition in the runtime of the SCADA system. Siemens has released new versions for the affected products and recommends to update to the latest versions.
Titel
SSA-723487 V1.4 (Last Update: 2025-01-14): RADIUS Protocol Susceptible to Forgery Attacks (CVE-2024-3596) - Impact to SCALANCE, RUGGEDCOM and Related Products
Veröffentlicht
14. Januar 2025 01:00
Text
This advisory documents the impact of CVE-2024-3596 (also dubbed “Blastradius”), a vulnerability in the RADIUS protocol, to SCALANCE, RUGGEDCOM and related products. The vulnerability could allow on-path attackers, located between a Network Access Server (the RADIUS client, e.g., SCALANCE or RUGGEDCOM devices) and a RADIUS server (e.g., SINEC INS), to ...
Titel
SSA-717113 V1.0: Cross-Site Request Forgery (CSRF) Vulnerability in SIMATIC S7-1200 CPUs before V4.7
Veröffentlicht
14. Januar 2025 01:00
Text
The web interface of SIMATIC S7-1200 CPUs before V4.7 is affected by a cross-site request forgery (CSRF) vulnerability. Siemens has released new versions for the affected products and recommends to update to the latest versions.
Titel
SSA-711309 V2.3 (Last Update: 2025-01-14): Denial of Service Vulnerability in the OPC UA Implementations of SIMATIC Products
Veröffentlicht
14. Januar 2025 01:00
Text
The OPC UA implementations (ANSI C and C++) as used in several SIMATIC products contain a denial of service vulnerability that could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate. Siemens has released new versions for several affected products and ...
Freitag, 10.01.2025
Titel
Schneider Electric PowerChute Serial Shutdown
Veröffentlicht
10. Januar 2025 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 6.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: PowerChute Serial Shutdown Vulnerability: Improper Authentication 2. RISK EVALUATION Successful exploitation of this vulnerability could cause a denial of access to the web interface when someone on the local network repeatedly requests the ...
Titel
Schneider Electric Harmony HMI and Pro-face HMI Products
Veröffentlicht
10. Januar 2025 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: Harmony HMI and Pro-face HMI Products Vulnerability: Use of Unmaintained Third-Party Components 2. RISK EVALUATION Successful exploitation of this vulnerability could cause complete control of the device when an authenticated user installs malicious ...
Titel
Delta Electronics DRASimuCAD (Update A)
Veröffentlicht
10. Januar 2025 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.4 ATTENTION: Low attack complexity Vendor: Delta Electronics Equipment: DRASimuCAD Vulnerabilities: Out-of-bounds Write, Type Confusion 2. RISK EVALUATION Successful exploitation of these vulnerabilities could crash the device or potentially allow remote code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of ...
Titel
Delta Electronics DRASimuCAD
Veröffentlicht
10. Januar 2025 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.4 ATTENTION: Low attack complexity Vendor: Delta Electronics Equipment: DRASimuCAD Vulnerabilities: Out-of-bounds Write, Type Confusion 2. RISK EVALUATION Successful exploitation of these vulnerabilities could crash the device or potentially allow remote code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of ...
Dienstag, 07.01.2025
Titel
Nedap Librix Ecoreader
Veröffentlicht
7. Januar 2025 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/Low attack complexity Vendor: Nedap Librix Equipment: Ecoreader Vulnerability: Missing Authentication for Critical Function 2. RISK EVALUATION Successful exploitation of this vulnerability could result in remote code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Ecoreader are ...
Titel
ABB ASPECT-Enterprise, NEXUS, and MATRIX Series Products
Veröffentlicht
7. Januar 2025 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: ABB Equipment: ASPECT-Enterprise, NEXUS, and MATRIX series Vulnerabilities: Files or Directories Accessible to External Parties, Improper Validation of Specified Type of Input, Cleartext Transmission of Sensitive Information, Cross-site Scripting, Server-Side Request Forgery (SSRF), Improper Neutralization of ...