• 1
  • 2 (current)
  • 3
Dienstag, 11.02.2025
Titel
SSA-770770 V1.0: Multiple Vulnerabilities in Fortigate NGFW on RUGGEDCOM APE1808 Devices
Veröffentlicht
11. Februar 2025 01:00
Text
Fortinet has published information on vulnerabilities in FortiOS. This advisory lists the related Siemens Industrial products. Siemens is preparing fix versions and recommends to consult and implement the workarounds provided in Fortinet’s upstream security notifications.
Titel
SSA-769027 V1.0: Multiple Vulnerabilities fixed in SCALANCE W700 IEEE 802.11ax devices before V3.0.0
Veröffentlicht
11. Februar 2025 01:00
Text
SCALANCE W-700 IEEE 802.11ax family devices are affected by multiple vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions.
Titel
SSA-767615 V1.0: Information Disclosure Vulnerability in SIPROTEC 5 Devices
Veröffentlicht
11. Februar 2025 01:00
Text
An information disclosure vulnerability in SIPROTEC 5 devices could allow an unauthenticated, remote attacker to retrieve sensitive information of the device. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products ...
Titel
SSA-712929 V2.9 (Last Update: 2025-02-11): Denial of Service Vulnerability in OpenSSL (CVE-2022-0778) Affecting Industrial Products
Veröffentlicht
11. Februar 2025 01:00
Text
A vulnerability in the openSSL component (CVE-2022-0778, [0]) could allow an attacker to create a denial of service condition by providing specially crafted elliptic curve certificates to products that use a vulnerable version of openSSL. Siemens has released new versions for several affected products and recommends to update to the ...
Titel
SSA-698820 V1.5 (Last Update: 2025-02-11): Multiple Vulnerabilities in Fortigate NGFW Before V7.4.4 on RUGGEDCOM APE1808 Devices
Veröffentlicht
11. Februar 2025 01:00
Text
Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products. Siemens has released a new version of Fortigate NGFW for RUGGEDCOM APE1808 and recommends to update to the latest version. Siemens recommends to consult and implement the workarounds provided in Fortinet’s upstream security notifications.
Titel
SSA-697140 V1.3 (Last Update: 2025-02-11): Denial of Service Vulnerability in the TCP Event Service of SCALANCE and RUGGEDCOM Products
Veröffentlicht
11. Februar 2025 01:00
Text
The products listed below contain a denial of service vulnerability in the TCP event interface that could allow an unauthenticated remote attacker to render the device unusable. Siemens has released updates for the affected products and recommends to update to the latest versions.
Titel
SSA-687955 V1.0: Accessible Development Shell via Physical Interface in SIPROTEC 5
Veröffentlicht
11. Februar 2025 01:00
Text
Affected SIPROTEC 5 devices contain a development shell which is accessible via a physical interface which is not properly restricted. This could allow an unauthenticated attacker with physical access to an affected device to execute arbitrary commands on the device. Siemens has released new versions for several affected products and ...
Titel
SSA-656895 V1.0: Open Redirect Vulnerability in Teamcenter Before V14.3
Veröffentlicht
11. Februar 2025 01:00
Text
The SSO login service in Teamcenter contains an open redirect vulnerability that could allow an attacker to redirect the legitimate user to an attacker-chosen URL to steal valid session data. Siemens has released a new version for Teamcenter and recommends to update to the latest version.
Titel
SSA-647005 V1.0: Memory Corruption Vulnerability in OpenV2G
Veröffentlicht
11. Februar 2025 01:00
Text
The open source software OpenV2G contains a buffer overflow vulnerability that could allow an attacker to trigger a memory corruption. Siemens has released an update for the OpenV2G and recommends to update to the latest version.
Titel
SSA-637914 V1.0: Local Code Execution Vulnerability in Questa and ModelSim Before V2025.1
Veröffentlicht
11. Februar 2025 01:00
Text
Questa and ModelSim (incl. OEM Editions) are affected by a vulnerability that could allow a local attacker to inject arbitrary code and escalate privileges. Siemens has released new versions for the affected products and recommends to update to the latest versions.
Titel
SSA-615116 V1.0: Multiple Vulnerabilities in Apogee PXC and Talon TC Devices
Veröffentlicht
11. Februar 2025 01:00
Text
Apogee PXC and Talon TC contain a vulnerability that could allow an attacker to perform a denial of service using a out-of-bounds read forcing the device to enter a cold state and a vulnerability that would allow an attacker to decrypt the passwords of the device. Siemens recommends countermeasures for ...
Titel
SSA-398330 V2.3 (Last Update: 2025-02-11): Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP V3.1
Veröffentlicht
11. Februar 2025 01:00
Text
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version V3.1 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not ...
Titel
SSA-369369 V1.0: Weak Registry Permission Vulnerability in SIMATIC IPC DiagBase and SIMATIC IPC DiagMonitor
Veröffentlicht
11. Februar 2025 01:00
Text
SIMATIC IPC DiagBase and SIMATIC IPC DiagMonitor contain a weak registry permission vulnerability that could allow an authenticated attacker to perform privilege escalation or bypass security measures. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.
Titel
SSA-354569 V1.1 (Last Update: 2025-02-11): Multiple Vulnerabilities in Palo Alto Networks Virtual NGFW on RUGGEDCOM APE1808 Devices
Veröffentlicht
11. Februar 2025 01:00
Text
Palo Alto Networks has published [1] information on vulnerabilities in PAN-OS. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens is preparing fix versions and recommends countermeasures for products where fixes are not, or not yet available. [1] https://security.paloaltonetworks.com/
Titel
SSA-349422 V2.2 (Last Update: 2025-02-11): Denial of Service Vulnerability in Industrial Real-Time (IRT) Devices
Veröffentlicht
11. Februar 2025 01:00
Text
A vulnerability in the affected products could allow an unauthorized attacker with network access to perform a denial-of-service attack resulting in loss of real-time synchronization. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes ...
Titel
SSA-342348 V1.0: Insufficient Session Expiration Vulnerability in Siemens Products
Veröffentlicht
11. Februar 2025 01:00
Text
Affected products do not correctly invalidate user sessions upon user logout. This could allow a remote unauthenticated attacker, who has obtained the session token by other means, to re-use a legitimate user’s session even after logout. Siemens has released new versions for several affected products and recommends to update to ...
Titel
SSA-246355 V1.0: Multiple Vulnerabilities in Tableau Server Component of Opcenter Intelligence
Veröffentlicht
11. Februar 2025 01:00
Text
The Tableau Server component in Opcenter Intelligence contains multiple vulnerabilities as described below. Siemens has released a new version for Opcenter Intelligence and recommends to update to the latest version and to install the latest available version of Tableau Server as described in https://support.sw.siemens.com/knowledge-base/PL8822108.
Titel
SSA-196737 V1.1 (Last Update: 2025-02-11): Multiple Vulnerabilities in SINEC Traffic Analyzer Before V1.2
Veröffentlicht
11. Februar 2025 01:00
Text
SINEC Traffic Analyzer before V1.2 is affected by multiple vulnerabilities. Siemens has released a new version for SINEC Traffic Analyzer and recommends to update to the latest version.
Titel
SSA-195895 V1.0: User Enumeration Vulnerability in the Webserver of SIMATIC Products
Veröffentlicht
11. Februar 2025 01:00
Text
The webserver of several SIMATIC products is affected by a user enumeration vulnerability that could allow an unauthenticated remote attacker to identify valid usernames. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific ...
Titel
SSA-194557 V1.1 (Last Update: 2025-02-11): Improper Limitation of Filesystem Access through Web Server Vulnerability in SIPROTEC 5
Veröffentlicht
11. Februar 2025 01:00
Text
Affected SIPROTEC 5 devices do not properly limit the access of the web server to the filesystem. This could allow an authenticated remote attacker to read arbitrary files or the entire filesystem of the device. Siemens has released new versions for several affected products and recommends to update to the ...
Titel
SSA-111547 V1.0: Cleartext Storage of Sensitive Information Vulnerability in SIPROTEC 5
Veröffentlicht
11. Februar 2025 01:00
Text
Affected SIPROTEC 5 devices do not encrypt certain data within the on-board flash storage on their PCB. This could allow an attacker with physical access to read the sensitive information from the filesystem of the device. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are ...
Donnerstag, 06.02.2025
Titel
ABB Drive Composer
Veröffentlicht
6. Februar 2025 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: ABB Equipment: Drive Composer Vulnerability: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') 2. RISK EVALUATION Successful exploitation of this vulnerability could allow attackers unauthorized access to the file system on the host ...
Titel
Schneider Electric EcoStruxure Power Monitoring Expert (PME)
Veröffentlicht
6. Februar 2025 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.1 ATTENTION: Exploitable remotely Vendor: Schneider Electric Equipment: EcoStruxure Power Monitoring Expert (PME) Vulnerability: Deserialization of Untrusted Data 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to remotely execute code. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Schneider Electric reports ...
Titel
Trimble Cityworks
Veröffentlicht
6. Februar 2025 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.6 ATTENTION: Exploitable remotely/low attack complexity/known public exploitation Vendor: Trimble Equipment: Cityworks Vulnerability: Deserialization of Untrusted Data 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an authenticated user to perform a remote code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The ...
Titel
Trimble Cityworks (Update A)
Veröffentlicht
6. Februar 2025 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.6 ATTENTION: Exploitable remotely/low attack complexity/known public exploitation Vendor: Trimble Equipment: Cityworks Vulnerability: Deserialization of Untrusted Data 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an authenticated user to perform a remote code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The ...
  • 1
  • 2 (current)
  • 3

Letzte Updates

BOSCH PSIRT
15.01.2025
SIEMENS CERT
11.03.2025
US CERT
19.02.2025
US CERT (ICS)
11.03.2025

Nach Quelle

Archiv

2025
2024
2023
2022
2021
2020
2019
2018
2017

Feeds