Donnerstag, 17.04.2025
Titel
Schneider Electric ConneXium Network Manager
Veröffentlicht
17. April 2025 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.4 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: ConneXium Network Manager Vulnerabilities: Files or Directories Accessible to External Parties, Improper Input Validation 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to access sensitive data, escalate privileges, or ...
Titel
Yokogawa Recorder Products
Veröffentlicht
17. April 2025 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Yokogawa Equipment: GX10, GX20, GP10, GP20, GM Data Acquisition System, DX1000, DX2000, DX1000N, FX1000, μR10000, μR20000, MW100, DX1000T, DX2000T, CX1000, CX2000 Vulnerability: Missing Authentication for Critical Function 2. RISK EVALUATION Successful exploitation of this vulnerability could ...
Titel
Schneider Electric Trio Q Licensed Data Radio
Veröffentlicht
17. April 2025 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 5.4 ATTENTION: Low attack complexity Vendor: Schneider Electric Equipment: Trio Q Licensed Data Radio Vulnerabilities: Insecure Storage of Sensitive Information, Initialization of a Resource with an Insecure Default 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to access confidential ...
Titel
Schneider Electric Sage Series
Veröffentlicht
17. April 2025 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: Sage series Vulnerabilities: Out-of-bounds Write, Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Incorrect Default Permissions, Unchecked Return Value, Buffer Copy without Checking Size of Input ('Classic Buffer Overflow'), Out-of-bounds ...
Titel
SSA-819629 V1.1 (Last Update: 2025-04-17): Weak Authentication Vulnerability in Industrial Edge Device Kit
Veröffentlicht
17. April 2025 02:00
Text
Users of Industrial Edge Devices are advised to consult the respective Security Advisories for their devices (for Siemens Industrial Edge devices see Additional Information). Industrial Edge Device Kit contains a weak authentication vulnerability that could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Industrial Edge ...
Mittwoch, 16.04.2025
Titel
SSA-366067 V1.2 (Last Update: 2025-04-16): Multiple Vulnerabilities in Fortigate NGFW on RUGGEDCOM APE1808 Devices
Veröffentlicht
16. April 2025 02:00
Text
Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products. Siemens has released a new version for RUGGEDCOM APE1808 and recommends to update to the latest version. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or ...
Titel
SSA-443402 V1.0: Multiple SQL Injection Vulnerabilities in TeleControl Server Basic before V3.1.2.2
Veröffentlicht
16. April 2025 02:00
Text
TeleControl Server Basic before V3.1.2.2 contains multiple SQL Injection vulnerabilities that could allow an attacker to read and write to the application’s DB, cause denial of service and execute code in an OS shell with limited “NT AUTHORITY” permissions. Siemens has conducted a root-cause analysis for potential SQL injection vulnerabilities ...
Titel
SSA-395348 V1.0: Improper Handling of Length Parameter Inconsistency Vulnerability in TeleControl Server Basic before V3.1.2.2
Veröffentlicht
16. April 2025 02:00
Text
TeleControl Server Basic before V3.1.2.2 contains a Improper Handling of Length Parameter Inconsistency Vulnerability that could allow an attacker to cause the application to allocate exhaustive amounts of memory and subsequently create a denial of service condition. Siemens has released a new version for TeleControl Server Basic and recommends to ...
Titel
SSA-832273 V1.8 (Last Update: 2025-04-16): Multiple Vulnerabilities in Fortigate NGFW on RUGGEDCOM APE1808 Devices
Veröffentlicht
16. April 2025 02:00
Text
Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products. Siemens has released a new version for RUGGEDCOM APE1808 and recommends to update to the latest version. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or ...
Dienstag, 15.04.2025
Titel
ABB M2M Gateway
Veröffentlicht
15. April 2025 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: ABB Equipment: M2M Gateway Vulnerabilities: Integer Overflow or Wraparound, Inconsistent Interpretation of HTTP Requests ('HTTP Request/Response Smuggling'), Unquoted Search Path or Element, Untrusted Search Path, Use After Free, Out-of-bounds Write, Buffer Copy without Checking Size of ...
Titel
Siemens SIMOCODE, SIMATIC, SIPLUS, SIDOOR, SIWAREX
Veröffentlicht
15. April 2025 14:00
Text
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY ...
Titel
Growatt Cloud Applications
Veröffentlicht
15. April 2025 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Growatt Equipment: Cloud Applications Vulnerabilities: Cross-site Scripting, Authorization Bypass Through User-Controlled Key, Insufficient Type Distinction, External Control of System or Configuration Setting 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to compromise ...
Titel
Delta Electronics COMMGR
Veröffentlicht
15. April 2025 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Delta Electronics Equipment: COMMGR Vulnerability: Use of Cryptographically Weak Pseudo-Random Number Generator (PRNG) 2. RISK EVALUATION Successful exploitation of this vulnerability could allow for an attacker to remotely access the AS3000Simulator family in the COMMGR software ...
Titel
Lantronix Xport
Veröffentlicht
15. April 2025 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Lantronix Equipment: Xport Vulnerability: Missing Authentication for Critical Function 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker unauthorized access to the configuration interface and cause disruption to monitoring and operations. 3. TECHNICAL ...
Titel
Mitsubishi Electric Europe B.V. smartRTU
Veröffentlicht
15. April 2025 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Mitsubishi Electric Europe B.V. Equipment: smartRTU Vulnerability: Missing Authentication for Critical Function, OS Command Injection 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow a remote unauthenticated attacker to disclose, tamper with, destroy or delete ...
Titel
Siemens Industrial Edge Device Kit
Veröffentlicht
15. April 2025 14:00
Text
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY ...
Montag, 14.04.2025
Titel
SSA-874353 V1.2 (Last Update: 2025-04-14): Entity Enumeration Vulnerability in Mendix Runtime
Veröffentlicht
14. April 2025 02:00
Text
Mendix Runtime allows for entity enumeration due to distinguishable responses in certain client actions. This could allow an unauthenticated remote attacker to list all valid entities and attribute names of a Mendix Runtime-based application. Siemens has released new versions for several affected products and recommends to update to the latest ...
Donnerstag, 10.04.2025
Titel
Siemens SIDIS Prime
Veröffentlicht
10. April 2025 14:00
Text
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY ...
Titel
Siemens Industrial Edge Devices
Veröffentlicht
10. April 2025 14:00
Text
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY ...
Titel
Siemens Insights Hub Private Cloud
Veröffentlicht
10. April 2025 14:00
Text
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY ...
Titel
Siemens SENTRON 7KT PAC1260 Data Manager
Veröffentlicht
10. April 2025 14:00
Text
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY ...
Titel
Siemens License Server
Veröffentlicht
10. April 2025 14:00
Text
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY ...
Titel
ABB Arctic Wireless Gateways
Veröffentlicht
10. April 2025 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.2 ATTENTION: Exploitable remotely/low attack complexity Vendor: ABB Equipment: Arctic Wireless Gateways Vulnerabilities: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow'), Improper Privilege Management, Exposure of Sensitive Information to an Unauthorized Actor, Improper Limitation of a Pathname to a Restricted Directory ...
Titel
SSA-874353 V1.1 (Last Update: 2025-04-10): Entity Enumeration Vulnerability in Mendix Runtime
Veröffentlicht
10. April 2025 02:00
Text
Mendix Runtime allows for entity enumeration due to distinguishable responses in certain client actions. This could allow an unauthenticated remote attacker to list all valid entities and attribute names of a Mendix Runtime-based application. Siemens has released new versions for several affected products and recommends to update to the latest ...
Dienstag, 08.04.2025
Titel
SSA-634640 V1.0: Weak Authentication Vulnerability in Siemens Industrial Edge Devices
Veröffentlicht
8. April 2025 02:00
Text
Siemens Industrial Edge Devices contain a weak authentication vulnerability that could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific ...