Titel
Delta Industrial Automation DIAEnergie
Veröffentlicht
13. September 2022 16:15
Text
This advisory contains mitigations for a Use of Hard-coded Credentials vulnerability in verisons of DIAEnergie, an industrial energy management system.
Titel
Kingspan TMS300 CS
Veröffentlicht
13. September 2022 16:10
Text
This advisory contains mitigations for an Improper Authentication vulnerability in Kingsapn TMS300 CS, a water tank management system.
Titel
Hitachi Energy TXpert Hub CoreTec 4 Sudo Vulnerability
Veröffentlicht
13. September 2022 16:00
Text
This advisory contains mitigations for an Off-by-one Error vulnerability in versions of Hitachi Energy TXpert Hub CoreTec 4, a digital transformer monitoring and diagnostics device.
Titel
Honeywell SoftMaster
Veröffentlicht
13. September 2022 16:00
Text
This advisory contains mitigations for Uncontrolled Search Path Element and Incorrect Permission Assignment for Critical Resource vulnerabilities in the SoftMaster desktop application, a PLC software application.
Titel
Baxter Sigma Spectrum Infusion Pump
Veröffentlicht
8. September 2022 16:20
Text
This advisory contains mitigations for Missing Encryption of Sensitive Data, Use of Externally Controlled Format String, Missing Authentication for Critical Function vulnerabilities in Sigma and Baxter Spectrum Infusion Pumps.
Titel
MZ Automation libIEC61850
Veröffentlicht
8. September 2022 16:15
Text
This advisory contains mitigations for Buffer Overflow, Access of Resource Using Incompatible Type, NULL Pointer Dereference vulnerabilities in libIEC61850 of IEC61850 implementation software.
Titel
Hillrom Medical Device Management (Update B)
Veröffentlicht
8. September 2022 16:05
Text
This updated advisory is a follow-up to the original advisory titled ICSMA-21-152-01 Hillrom Medical Device Management (Update A) that was published June 1, 2021, to the ICS webpage at cisa.gov/ics. This advisory contains mitigations for Out-of-bounds Write, Out-of-bounds Read vulnerabilities in Welch Allyn medical device management tools.
Titel
PTC Kepware KEPServerEX (Update A)
Veröffentlicht
8. September 2022 16:00
Text
This updated advisory is a follow-up to the original advisory titled ICSA-22-242-10 PTC Kepware KEPServerEX that was published August 30, 2022, to the ICS webpage at www.cisa.gov/ics. This advisory contains mitigations for Kepware KEPServerEX vulnerabilities in Heap-based Buffer Overflow, Stack-based Buffer Overflow.
Titel
Triangle Microworks Libraries
Veröffentlicht
6. September 2022 16:50
Text
This advisory contains mitigations for Access of Uninitialized Pointer vulnerabilities in Triangle Microworks, TMW IEC 61850 Software Library and TMW IEC 60870-6 (ICCP/TASE.2) Software Library.
Titel
AVEVA Edge 2020 R2 SP1 and all prior versions
Veröffentlicht
6. September 2022 16:40
Text
This advisory contains mitigations for Insufficient UI Warning of Dangerous Operations, Uncontrolled Search Path Element, and Deserialization of Untrusted Data, Improper Restriction of XML External Entity Reference vulnerabilities in versions of AVEVA Edge, an industrial software system.
Titel
Cognex 3D-A1000 Dimensioning System
Veröffentlicht
6. September 2022 16:20
Text
This advisory contains mitigations for Missing Authentication for Critical Function, Improper Output Neutralization for Logs, and Client-side Enforcement of Server-side Security vulnerabilities in versions of Cognex 3DS-A1000 Dimensioning System, an industrial smart camera.
Titel
Hitachi Energy TXpert Hub CoreTec 4
Veröffentlicht
6. September 2022 16:10
Text
This advisory contains mitigations for Authentication Bypass Using an Alternate Path or Channel and Improper Input Validation, Download of Code Without Integrity Check vulnerabilities in versions of Hitachi Energy TXpert Hub CoreTec 4, a digital transformer monitoring and diagnostics device.
Titel
Delta Electronics DOPSoft 2 (Update A)
Veröffentlicht
6. September 2022 16:00
Text
This updated advisory is a follow-up to the advisory update titled ICSA-21-252-02 Delta Electronics DOPSoft2 that was published September 09, 2021, to the ICS webpage on cisa.gov/ics. This advisory contains mitigations for Stack-based Buffer Overflow, Out-of-Bounds Write, and Heap-based Buffer Overflow vulnerabilities in Delta Electronics DOPSoft 2 HMI editing software.
Titel
Contec Health CMS8000
Veröffentlicht
1. September 2022 16:10
Text
This advisory contains mitigations for Improper Access Control, Uncontrolled Resource Consumption, Use of Hard-Coded Credentials, Active Debug Code vulnerabilities in Contec Health CMS8000, a ICU CCU Vital Signs Patient Monitor.
August 2022
Titel
Hitachi Energy FACTS Control Platform (FCP) Product
Veröffentlicht
30. August 2022 16:55
Text
This advisory contains mitigations for Inconsistent Interpretation of HTTP Requests, Use After Free, Classic Buffer Overflow, Integer Underflow, Improper Certificate Validation, Observable Discrepancy vulnerabilities in Hitachi Energy FACTS Control Platform (FCP).
Titel
Hitachi Energy Gateway Station (GWS) Product
Veröffentlicht
30. August 2022 16:50
Text
This advisory contains mitigations for a Hitachi Energy Gateway Station (GWS) Product vulnerability in Inconsistent Interpretation of HTTP Requests, Use After Free, Classic Buffer Overflow, Integer Underflow, Improper Certificate Validation, Observable Discrepancy.
Titel
Hitachi Energy MSM Product
Veröffentlicht
30. August 2022 16:40
Text
This advisory contains mitigations for a Hitachi Energy MSM Product vulnerability in Reliance on Uncontrolled Component.
Titel
Fuji Electric D300win
Veröffentlicht
30. August 2022 16:30
Text
This advisory contains mitigations for a Fuji Electric D300win vulnerability Out-of-bounds Read, Write-what-where Condition
Titel
Honeywell ControlEdge
Veröffentlicht
30. August 2022 16:30
Text
This advisory contains mitigations for a Honeywell ControlEdge vulnerability Missing Authentication for Critical Function.
Titel
Honeywell Experion LX
Veröffentlicht
30. August 2022 16:25
Text
This advisory contains mitigations for a Missing Authentication for Critical Function vulnerability in versions of the Honeywell equipment, Experion LX, distributed control system (DCS).
Titel
Honeywell Trend Controls Inter-Controller Protocol
Veröffentlicht
30. August 2022 16:20
Text
This advisory contains mitigations for a Cleartext Transmission of Sensitive Information vulnerability in versions of the Honeywell products, Trend Controls IQ Series IC, an industrial communication controller.
Titel
PTC Kepware KEPServerEX
Veröffentlicht
30. August 2022 16:10
Text
This advisory contains mitigations for Heap-Based Buffer Overflow and Stack-Based Buffer Overflow vulnerabilities in versions of the PTC product, Kepware KEPServerEX, a connectivity platform.
Titel
Measuresoft ScadaPro Server and Client
Veröffentlicht
23. August 2022 17:06
Text
This advisory contains mitigations for Untrusted Pointer Dereference, Stack-based Buffer Overflow, Use After Free, and Link Following vulnerabilities in Measuresoft ScadaPro Server and Client, a supervisory control and data acquisition (SCADA) system.
Titel
Measuresoft ScadaPro Server
Veröffentlicht
23. August 2022 17:04
Text
This advisory contains mitigations for an Out-of-bounds Write vulnerability in Measuresoft ScadaPro Server, a supervisory control and data acquisition (SCADA) system.
Titel
Hitachi Energy RTU500
Veröffentlicht
23. August 2022 17:02
Text
This advisory contains mitigations for a Stack-based Buffer Overflow vulnerability in versions of Hitatchi Energy RTU500 firmware.