September 2021
Titel
Siemens RUGGEDCOM ROX
Veröffentlicht
16. September 2021 16:05
Text
This advisory contains mitigations for Exposure of Sensitive Information to an Unauthorized Actor, Execution with Unnecessary Privileges, and Improper Handling of Insufficient Permissions or Privileges vulnerabilities in Siemens RUGGEDCOM ROX devices.
Titel
Schneider Electric EcoStruxure and SCADAPack
Veröffentlicht
16. September 2021 16:00
Text
This advisory contains mitigations for a Path Traversal vulnerability in Schneider Electric EcoStruxure Control Expert, EcoStruxure Process Expert, SCADAPack RemoteConnect software designed for the x70 SCADAPack system.
Titel
Digi PortServer TS 16
Veröffentlicht
14. September 2021 17:26
Text
This advisory contains mitigations for an Improper Authentication vulnerability in Digi PortServer TS 16 terminal servers.
Titel
Johnson Controls Sensormatic Electronics KT-1
Veröffentlicht
14. September 2021 17:24
Text
This advisory contains mitigations for an Authentication Bypass by Capture-replay vulnerability in Sensormatic Electronics KT-1 door controllers. Sensormatic Electronics is a subsidiary of Johnson Controls.
Titel
Schneider Electric Struxureware Data Center Expert
Veröffentlicht
14. September 2021 17:22
Text
This advisory contains mitigations for OS Command Injection, and Path Traversal vulnerabilities in Schneider Electric Struxureware Data Center Expert monitoring software.
Titel
Siemens Simcenter Femap
Veröffentlicht
14. September 2021 17:20
Text
This advisory contains mitigations for an Out-of-bounds Read vulnerability in the Siemens Simenter Femap simulation application.
Titel
Siemens Simcenter STAR-CCM+ Viewer
Veröffentlicht
14. September 2021 17:18
Text
This advisory contains mitigations for an Out-of-bounds Write vulnerability in the Siemens Simcenter Star-CCM+ Viewer simulation application.
Titel
Siemens SIMATIC CP
Veröffentlicht
14. September 2021 17:16
Text
This advisory contains mitigations for a Cleartext Storage of Sensitive Information vulnerability in Siemens SIMATIC CP communication processors.
Titel
Siemens APOGEE and TALON
Veröffentlicht
14. September 2021 17:14
Text
This advisory contains mitigations for a Classic Buffer Overflow vulnerability in Siemens APOGEE and TALON building automation systems.
Titel
Siemens Teamcenter Active Workspace
Veröffentlicht
14. September 2021 17:12
Text
This advisory contains mitigations for a Path Traversal vulnerability in the Siemens Teamcenter Active Workspace product lifecycle management system.
Titel
Siemens Teamcenter
Veröffentlicht
14. September 2021 17:12
Text
This advisory contains mitigations for Privilege Defined with Unsafe Actions, Authorization Bypass Through User-Controlled Key, and Improper Restriction of XML External Entity Reference vulnerabilities in the Siemens Teamcenter virtualization platform.
Titel
Siemens NX
Veröffentlicht
14. September 2021 17:10
Text
This advisory contains mitigations for Use After Free, and Out-of-bounds Read vulnerabilities in Siemens NX industrial software.
Titel
Siemens SIPROTEC 5 relays
Veröffentlicht
14. September 2021 17:08
Text
This advisory contains mitigations for Classic Buffer Overflow vulnerabilities in Siemens SIPROTEC 5 relays.
Titel
AVEVA PCS Portal
Veröffentlicht
9. September 2021 16:15
Text
This advisory contains mitigations for an Uncontrolled Search Path Element vulnerability in AVEVA PCS Portal sofware.
Titel
Delta Electronics DOPSoft 2
Veröffentlicht
9. September 2021 16:10
Text
This advisory contains mitigations for Stack-based Buffer Overflow, Out-of-Bounds Write, and Heap-based Buffer Overflow vulnerabilities in Delta Electronics DOPSoft 2 HMI editing software.
Titel
Mitsubishi Electric Europe B.V. smartRTU and INEA ME-RTU
Veröffentlicht
9. September 2021 16:05
Text
This advisory is a follow-up to a CISA product update titled ICS-ALERT-19-225-01 Mitsubishi Electric Europe B.V. smartRTU and INEA ME-RTU (Update A) published September 10, 2019, on the ICS webpage on us-cert.cisa.gov. This advisory contains mitigations for OS Command Injection, Improper Access Control, Cross-site Scripting, Use of Hard-coded Credentials, Unprotected ...
Titel
Mitsubishi Electric Multiple Products (Update C)
Veröffentlicht
9. September 2021 16:00
Text
This updated advisory is a follow-up to the advisory update titled ICSA-20-245-01 Mitsubishi Electric Multiple Products (Update B) that was published May 18, 2021, to the ICS webpage on us-cert.cisa.gov. This advisory contains mitigations for a Predictable Exact Value from Previous Values vulnerability in several Mitsubishi Electric devices.
Titel
Hitachi ABB Power Grids System Data Manager
Veröffentlicht
7. September 2021 16:00
Text
This advisory contains mitigations for a Cleartext Storage of Sensitive Information vulnerability in Hitachi ABB Power Grids System Data Manager products.
Titel
Johnson Controls Sensormatic Electronics Illustra
Veröffentlicht
2. September 2021 16:10
Text
This advisory contains mitigations for an Off-by-one Error vulnerability in Johnson Controls Sensormatic Electronics Illustra camera systems.
Titel
JTEKT TOYOPUC Products
Veröffentlicht
2. September 2021 16:05
Text
This advisory contains mitigations for a Allocation of Resources Without Limits or Throttling vulnerability in JTEKT TOYOPUC industrial system hardware products.
August 2021
Titel
Sensormatic Electronics KT-1
Veröffentlicht
31. August 2021 16:05
Text
This advisory contains mitigations for a Use of Unmaintained Third-party Components vulnerability in Sensormatic Electronics KT-1 Ethernet-ready single-door controller.
Titel
Philips Patient Monitoring Devices (Update A)
Veröffentlicht
31. August 2021 16:00
Text
This updated advisory is a follow-up to the original advisory titled ICSMA-20-254-01 Philips Patient Monitoring Devices that was published September 10, 2020, to the ICS webpage on us-cert.cisa.gov. This advisory contains mitigations for Improper Neutralization of Formula Elements in a CSV File, Cross-site Scripting, Improper Authentication, Improper Check for Certificate ...
Titel
Johnson Controls Controlled Electronic Management Systems CEM Systems AC2000
Veröffentlicht
26. August 2021 16:15
Text
This advisory contains mitigation for an Improper Authorization vulnerability in Johnson Controls Controlled Electronic Management Systems CEM Systems AC2000, an enterprise access control and integrated security management system.​​​​
Titel
Annke Network Video Recorder
Veröffentlicht
26. August 2021 16:10
Text
This advisory contains mitigation for a Stack-based Buffer Overflow vulnerability in the Annke N48PBB Network Video Recorder.
Titel
Delta Electronics DIAEnergie
Veröffentlicht
26. August 2021 16:05
Text
This advisory contains mitigations for Use of Password Hash with Insufficient Computational Effort, Incorrect Authorization, Unrestricted Upload of File with Dangerous Type, SQL Injection, and Cross-site Request Forgery vulnerabilities in the Delta Electronics DIAEnergie industrial energy management system.