Article No° | Product Name | Affected Version(s) |
---|---|---|
1241070000 | IE-SW-PL08M-6TX-2SC | <= V3.3.8 Build 16102416 |
1241090000 | IE-SW-PL08M-6TX-2SCS | <= V3.3.8 Build 16102416 |
1241080000 | IE-SW-PL08M-6TX-2ST | <= V3.3.8 Build 16102416 |
1241040000 | IE-SW-PL08M-8TX | <= V3.3.8 Build 16102416 |
1286790000 | IE-SW-PL08MT-6TX-2SC | <= V3.3.8 Build 16102416 |
1286810000 | IE-SW-PL08MT-6TX-2SCS | <= V3.3.8 Build 16102416 |
1286800000 | IE-SW-PL08MT-6TX-2ST | <= V3.3.8 Build 16102416 |
1286780000 | IE-SW-PL08MT-8TX | <= V3.3.8 Build 16102416 |
1241370000 | IE-SW-PL09M-5GC-4GT | <= V3.3.4 Build 16102416 |
1287020000 | IE-SW-PL09MT-5GC-4GT | <= V3.3.4 Build 16102416 |
1241300000 | IE-SW-PL10M-1GT-2GS-7TX | <= V3.3.16 Build 16102416 |
1241290000 | IE-SW-PL10M-3GT-7TX | <= V3.3.16 Build 16102416 |
1286940000 | IE-SW-PL10MT-1GT-2GS-7TX | <= V3.3.16 Build 16102416 |
1286930000 | IE-SW-PL10MT-3GT-7TX | <= V3.3.16 Build 16102416 |
1241120000 | IE-SW-PL16M-14TX-2SC | <= V3.4.2 Build 16102416 |
1241130000 | IE-SW-PL16M-14TX-2ST | <= V3.4.2 Build 16102416 |
1241100000 | IE-SW-PL16M-16TX | <= V3.4.2 Build 16102416 |
1286830000 | IE-SW-PL16MT-14TX-2SC | <= V3.4.2 Build 16102416 |
1286840000 | IE-SW-PL16MT-14TX-2ST | <= V3.4.2 Build 16102416 |
1286820000 | IE-SW-PL16MT-16TX | <= V3.4.2 Build 16102416 |
1241330000 | IE-SW-PL18M-2GC14TX2SC | <= V3.4.4 Build 16102416 |
1241350000 | IE-SW-PL18M-2GC14TX2SCS | <= V3.4.4 Build 16102416 |
1241340000 | IE-SW-PL18M-2GC14TX2ST | <= V3.4.4 Build 16102416 |
1241320000 | IE-SW-PL18M-2GC-16TX | <= V3.4.4 Build 16102416 |
1286990000 | IE-SW-PL18MT-2GC14TX2SC | <= V3.4.4 Build 16102416 |
1287010000 | IE-SW-PL18MT-2GC14TX2SCS | <= V3.4.4 Build 16102416 |
1287000000 | IE-SW-PL18MT-2GC14TX2ST | <= V3.4.4 Build 16102416 |
1286970000 | IE-SW-PL18MT-2GC-16TX | <= V3.4.4 Build 16102416 |
1504330000 | IE-SW-VL05M-3TX-2SC | <= V3.6.6 Build 16102415 |
1504370000 | IE-SW-VL05M-3TX-2ST | <= V3.6.6 Build 16102415 |
1504280000 | IE-SW-VL05M-5TX | <= V3.6.6 Build 16102415 |
1504350000 | IE-SW-VL05MT-3TX-2SC | <= V3.6.6 Build 16102415 |
1504390000 | IE-SW-VL05MT-3TX-2ST | <= V3.6.6 Build 16102415 |
1504310000 | IE-SW-VL05MT-5TX | <= V3.6.6 Build 16102415 |
1345240000 | IE-SW-VL08MT-5TX-1SC-2SCS | <= V3.5.2 Build 16102415 |
1240970000 | IE-SW-VL08MT-5TX-3SC | <= V3.5.2 Build 16102415 |
1344770000 | IE-SW-VL08MT-6TX-2SC | <= V3.5.2 Build 16102415 |
1241020000 | IE-SW-VL08MT-6TX-2SCS | <= V3.5.2 Build 16102415 |
1240990000 | IE-SW-VL08MT-6TX-2ST | <= V3.5.2 Build 16102415 |
1240940000 | IE-SW-VL08MT-8TX | <= V3.5.2 Build 16102415 |
Multiple issues have been found. Please check the CVEs for details.
Please check the CVEs for details.
For all potential vulnerabilities, customers can download a patched firmware to secure their switches properly. Please download and install the latest firmware for your switch by following the procedure below:
Use the link www.weidmueller.com
Solution for CVE-2019-16672
a.) Solution for vulnerability, valid for switch series IE-SW-VL05M and IE-SW-VL08MT
To avoid the vulnerabilities referred to in this section, it is necessary to install patched firmware. After installation of patched firmware the web interface can be accessed via encrypted communication using https, and web interface access can be configured to ensure encrypted connections by selecting “https only”.
The respective web interface menu section for this setting can be reached via the following path:
Main Menu > Basic Settings > System: Set the “Web Configuration” to ”https only”
b.) Solution for vulnerability, valid for switch series IE-SW-PL08M, IE-SW-PL10M, IE-SW-PL16M, IE-SW-PL18M, IE-SW-PL09M
To avoid the vulnerabilities referred to in this section, installation of patched firmware is not necessary. Web interface access can be configured to ensure encrypted connections by selecting “https only”.
The respective web interface menu section for this setting can be reached via the following path:
Main Menu > Basic Settings > System: Set the “Web Configuration” to ”https only”
Solution for CVE-2019-16670, CVE-2019-16671, CVE-2019-16673, CVE-2019-16674
Solution for vulnerabilities, valid for switch series IE-SW-VL05M, IE-SW-VL08MT, IE-SW-PL08M, IE-SW-PL10M, IE-SW-PL16M, IE-SW-PL18M, IE-SW-PL09M
After installing the patched firmware on the switch, it is possible to disable the unencrypted search service via Weidmüllermüller configuration software named “WM Switch Utility” for Windows OS and to enable an encrypted search service, that will be working with the new “Weidmüllermüller Switch Configuration Utility”. (available soon)
Both services – the encrypted and the unencrypted search service - are enabled by default. To avoid the vulnerabilities referred to in this section the unencrypted search service should be disabled.
The respective web interface menu section for this setting can be reached via the following path:
Main Menu > Basic Settings > Security > Management Interface: Uncheck the checkbox “Enable Search Service”
Note: After disabling the unencrypted search service the switches can no longer be found or configured with the current “WM Switch Utility”! Web interface settings are not affected by this configuration.
---
Please find below the appropriate patched firmware versions for all affected products.
Product number |
Product name |
Patched firmware version |
1504280000 |
IE-SW-VL05M-5TX |
≥ V3.6.24_Build_19062809 |
1504310000 |
IE-SW-VL05MT-5TX |
|
1504330000 |
IE-SW-VL05M-3TX-2SC |
|
1504350000 |
IE-SW-VL05MT-3TX-2SC |
|
1504370000 |
IE-SW-VL05M-3TX-2ST |
|
1504390000 |
IE-SW-VL05MT-3TX-2ST |
|
1240940000 |
IE-SW-VL08MT-8TX |
≥ V3.5.22_Build_19062810 |
1240970000 |
IE-SW-VL08MT-5TX-3SC |
|
1345240000 |
IE-SW-VL08MT-5TX-1SC-2SCS |
|
1240990000 |
IE-SW-VL08MT-6TX-2ST |
|
1344770000 |
IE-SW-VL08MT-6TX-2SC |
|
1241020000 |
IE-SW-VL08MT-6TX-2SCS |
|
1241040000 |
IE-SW-PL08M-8TX |
≥ V3.3.16_Build_19062811 |
1286780000 |
IE-SW-PL08MT-8TX |
|
1241070000 |
IE-SW-PL08M-6TX-2SC |
|
1286790000 |
IE-SW-PL08MT-6TX-2SC |
|
1241080000 |
IE-SW-PL08M-6TX-2ST |
|
1286800000 |
IE-SW-PL08MT-6TX-2ST |
|
1241090000 |
IE-SW-PL08M-6TX-2SCS |
|
1286810000 |
IE-SW-PL08MT-6TX-2SCS |
|
1241290000 |
IE-SW-PL10M-3GT-7TX |
≥ V3.3.24_Build_19062813 |
1286930000 |
IE-SW-PL10MT-3GT-7TX |
|
1241300000 |
IE-SW-PL10M-1GT-2GS-7TX |
|
1286940000 |
IE-SW-PL10MT-1GT-2GS-7TX |
|
1241100000 |
IE-SW-PL16M-16TX |
≥ V3.4.18_Build_19062814 |
1286820000 |
IE-SW-PL16MT-16TX |
|
1241120000 |
IE-SW-PL16M-14TX-2SC |
|
1286830000 |
IE-SW-PL16MT-14TX-2SC |
|
1241130000 |
IE-SW-PL16M-14TX-2ST |
|
1286840000 |
IE-SW-PL16MT-14TX-2ST |
|
1241320000 |
IE-SW-PL18M-2GC-16TX |
≥ V3.4.30_Build_19062817 |
1286970000 |
IE-SW-PL18MT-2GC-16TX |
|
1241330000 |
IE-SW-PL18M-2GC14TX2SC |
|
1286990000 |
IE-SW-PL18MT-2GC14TX2SC |
|
1241340000 |
IE-SW-PL18M-2GC14TX2ST |
|
1287000000 |
IE-SW-PL18MT-2GC14TX2ST |
|
1241350000 |
IE-SW-PL18M-2GC14TX2SCS |
|
1287010000 |
IE-SW-PL18MT-2GC14TX2SCS |
|
1241370000 |
IE-SW-PL09M-5GC-4GT |
≥ V3.3.20_Build_19070111 |
1287020000 |
IE-SW-PL09MT-5GC-4GT |
For support please contact Weidmüller at www.weidmueller.com/service.
Reported by Weidmüller