• 1
  • 2 (current)
  • 3
Dienstag, 13.05.2025
Titel
Hitachi Energy Service Suite
Veröffentlicht
13. Mai 2025 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Hitachi Energy Equipment: Service Suite Vulnerabilities: Use of Less Trusted Source, Inconsistent Interpretation of HTTP Requests ('HTTP Request/Response Smuggling'), Integer Overflow or Wraparound, Out-of-bounds Write, Allocation of Resources Without Limits or Throttling, Exposure of Sensitive Information ...
Titel
ABB Automation Builder
Veröffentlicht
13. Mai 2025 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.5 ATTENTION: Low attack complexity Vendor: ABB Equipment: Automation Builder Vulnerabilities: Incorrect Permission Assignment for Critical Resource 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to overrule the Automation Builder's user management. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The ...
Titel
Hitachi Energy MACH GWS Products
Veröffentlicht
13. Mai 2025 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.4 ATTENTION: Exploitable remotely/low attack complexity Vendor: Hitachi Energy Equipment: MACH GWS products Vulnerabilities: Improper Neutralization of Special Elements in Data Query Logic, Improper Limitation of a Pathname to a Restricted Directory, Authentication Bypass by Capture-replay, Missing Authentication for Critical Function 2. RISK ...
Titel
Hitachi Energy Relion 670/650/SAM600-IO Series
Veröffentlicht
13. Mai 2025 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.1 ATTENTION: Low attack complexity Vendor: Hitachi Energy Equipment: Relion 670/650/SAM600-IO Series Vulnerability: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') 2. RISK EVALUATION Successful exploitation of this vulnerability can allow an attacker to reboot the device and cause a denial-of-service ...
Titel
SSA-455250 V1.6 (Last Update: 2025-05-13): Multiple Vulnerabilities in Palo Alto Networks Virtual NGFW on RUGGEDCOM APE1808 Devices Before V11.1.2-h3
Veröffentlicht
13. Mai 2025 02:00
Text
Palo Alto Networks has published [1] information on vulnerabilities in PAN-OS. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens has released a new version of Palo Alto Networks Virtual NGFW for RUGGEDCOM APE1808 and recommends to update to the latest version. Customers are advised to ...
Titel
SSA-446307 V1.0: Authentication Bypass Vulnerability in BMC (CVE-2024-54085) affects SIMATIC IPC RS-828A
Veröffentlicht
13. Mai 2025 02:00
Text
SIMATIC IPC RS-828A is affected by an authentication bypass vulnerability in the Redfish interface of its Baseboard Management Controller (BMC) that could allow an attacker to gain unauthorized access and compromise confidentiality, integrity and availability of the BMC and thus the entire system. Siemens is preparing fix versions and recommends ...
Titel
SSA-373591 V1.1 (Last Update: 2025-05-13): Buffer Overflow Vulnerability in RUGGEDCOM ROS Devices
Veröffentlicht
13. Mai 2025 02:00
Text
The latest update for RUGGEDCOM ROS devices fixes a buffer overflow vulnerability in the third party component that could allow an attacker with network access to an affected device to cause a remote code execution condition. Siemens has released updates for the affected products and recommends to update to the ...
Titel
SSA-366067 V1.3 (Last Update: 2025-05-13): Multiple Vulnerabilities in Fortigate NGFW Before V7.4.1 on RUGGEDCOM APE1808 Devices
Veröffentlicht
13. Mai 2025 02:00
Text
Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products. Siemens has released a new version for RUGGEDCOM APE1808 and recommends to update to the latest version. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or ...
Titel
SSA-354569 V1.4 (Last Update: 2025-05-13): Multiple Vulnerabilities in Palo Alto Networks PAN-OS on RUGGEDCOM APE1808 Devices
Veröffentlicht
13. Mai 2025 02:00
Text
Palo Alto Networks has published [1] information on vulnerabilities in PAN-OS. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens is preparing fix versions and recommends countermeasures for products where fixes are not, or not yet available. [1] https://security.paloaltonetworks.com/
Titel
SSA-339086 V1.0: Insufficient Session Expiration Vulnerability in SIMATIC PCS neo
Veröffentlicht
13. Mai 2025 02:00
Text
Affected products do not correctly invalidate user sessions upon user logout. This could allow a remote unauthenticated attacker, who has obtained the session token by other means, to re-use a legitimate user’s session even after logout. Siemens has released new versions for the affected products and recommends to update to ...
Titel
SSA-327438 V1.0: Multiple Vulnerabilities in SCALANCE LPE9403
Veröffentlicht
13. Mai 2025 02:00
Text
SCALANCE LPE9403 is affected by multiple vulnerabilities which lead to a compromise in availability, integrity and confidentiality. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.
Titel
SSA-301229 V1.0: Client-Side Enforcement of Server-Side Security Vulnerabilities in RUGGEDCOM ROX II
Veröffentlicht
13. Mai 2025 02:00
Text
The web interface of RUGGEDCOM ROX II devices contain multiple Client-Side Enforcement of Server-Side Security vulnerabilities that could allow an attacker with a legitimate, highly privileged account on the web interface to get privileged code execution in the underlying OS of the affected products. Siemens has released new versions for ...
Titel
SSA-222768 V1.0: Multiple Vulnerabilities in SIRIUS 3SK2 Safety Relays and 3RK3 Modular Safety Systems
Veröffentlicht
13. Mai 2025 02:00
Text
SIRIUS 3SK2 Safety Relays and 3RK3 Modular Safety Systems only provide weak password obfuscation. An attacker with access to the PROFINET or serial interface of the device could eavesdrop or read the stored password from the device and de-obfuscate it. The safety passwords work as protection against unauthorized operation (i.e., ...
Titel
SSA-162255 V1.0: Multiple Vulnerabilities in Polarion Before V2410
Veröffentlicht
13. Mai 2025 02:00
Text
Polarion before V2410 contains multiple vulnerabilities that could allow attackers to extract data, conduct cross-site scripting attacks or find out valid usernames. Siemens strongly recommends to update Polarion to V2410 or later versions, not only to fix the documented vulnerabilities, but also to benefit from all the other improvements and ...
Titel
SSA-876787 V1.6 (Last Update: 2025-05-13): Open Redirect Vulnerability in SIMATIC S7-1500 and S7-1200 CPUs
Veröffentlicht
13. Mai 2025 02:00
Text
Several SIMATIC S7-1500 and S7-1200 CPU versions are affected by an open redirect vulnerability that could allow an attacker to make the web server of affected devices redirect a legitimate user to an attacker-chosen URL. For a successful attack, the legitimate user must actively click on an attacker-crafted link. Siemens ...
Titel
SSA-103653 V1.1 (Last Update: 2025-05-13): Denial-of-Service Vulnerability in Automation License Manager
Veröffentlicht
13. Mai 2025 02:00
Text
A vulnerability was identified in the Automation License Manager software that could be triggered by sending specially crafted packets to port 4410/tcp of an affected system. This could cause a denial-of-service preventing legitimate users from using the system. Siemens has released new versions for several affected products and recommends to ...
Titel
SSA-054046 V1.5 (Last Update: 2025-05-13): Unauthenticated Information Disclosure in Web Server of SIMATIC S7-1500 CPUs
Veröffentlicht
13. Mai 2025 02:00
Text
Several SIMATIC S7-1500 CPU versions are affected by an authentication bypass vulnerability that could allow an unauthenticated remote attacker to gain knowledge about actual and configured maximum cycle times and communication load of the CPU. Siemens has released new versions for several affected products and recommends to update to the ...
Titel
SSA-047424 V1.0: Code Execution and SQL Injection Vulnerabilities in OZW Web Servers
Veröffentlicht
13. Mai 2025 02:00
Text
OZW672 and OZW772 Web Server versions contain vulnerabilities that could allow an attacker to execute arbitrary code on the device with root privileges (in versions before V8.0) or to authenticate as Administrator user (in versions before V6.0). Siemens has released new versions for the affected products and recommends to update ...
Titel
SSA-039007 V1.5 (Last Update: 2025-05-13): Heap-based Buffer Overflow Vulnerability in User Management Component (UMC)
Veröffentlicht
13. Mai 2025 02:00
Text
Siemens User Management Component (UMC) is affected by a heap-based buffer overflow vulnerability which could allow an unauthenticated remote attacker arbitrary code execution. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures ...
Titel
SSA-901508 V1.0: Multiple Vulnerabilities in INTRALOG WMS Before V5
Veröffentlicht
13. Mai 2025 02:00
Text
INTRALOG WMS before V5 is affected by multiple vulnerabilities in the Microsoft .NET implementation as described below. Siemens has released a new version for INTRALOG WMS and recommends to update to the latest version. Please approach your INTRALOG WMS contact to resolve the reported vulnerabilities for your solution. When contacting ...
Titel
SSA-928984 V1.2 (Last Update: 2025-05-13): Heap-based Buffer Overflow Vulnerability in User Management Component (UMC)
Veröffentlicht
13. Mai 2025 02:00
Text
Siemens User Management Component (UMC) is affected by a heap-based buffer overflow vulnerability which could allow an unauthenticated remote attacker arbitrary code execution. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures ...
Titel
SSA-935500 V1.3 (Last Update: 2025-05-13): Denial of Service Vulnerability in FTP Server of Nucleus RTOS based APOGEE, TALON and Desigo PXC/PXM Products
Veröffentlicht
13. Mai 2025 02:00
Text
A denial of service vulnerability has been identified in the Nucleus RTOS (real-time operating system) and reported in the Siemens Security Advisory SSA-313313: https://cert-portal.siemens.com/productcert/html/ssa-313313.html. The products listed below use affected versions of the Nucleus software and inherently contain the vulnerability. Siemens has released new versions for several affected products and ...
Titel
SSA-673996 V1.2 (Last Update: 2025-05-13): Buffer Overflow Vulnerability in Third-Party Component in SICAM and SITIPE Products
Veröffentlicht
13. Mai 2025 02:00
Text
Multiple SICAM products are affected by buffer overflow vulnerability in the IEC 61850 Client libraries from Triangle MicroWorks that could allow an unauthenticated remote attacker to create a denial of service condition by sending specially crafted MMS messages. Affected SICAM and SITIPE products: SICAM A8000 Device firmware ET85 for CP-8000/CP-8021/CP-8022 ...
Titel
SSA-614723 V1.0: Denial of Service Vulnerabilities in User Management Component (UMC)
Veröffentlicht
13. Mai 2025 02:00
Text
Siemens User Management Component (UMC) is affected by three vulnerabilities which could allow an unauthenticated remote attacker to cause a denial of service condition. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific ...
Titel
SSA-556937 V1.0: Multiple Vulnerabilities in VersiCharge AC Series EV Chargers
Veröffentlicht
13. Mai 2025 02:00
Text
VersiCharge AC Series EV Chargers contain two vulnerabilities that could allow an attacker to gain control of the chargers through default Modbus port or execute arbitrary code by manipulating the M0 firmware. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens ...
  • 1
  • 2 (current)
  • 3

Letzte Updates

BOSCH PSIRT
25.04.2025
SIEMENS CERT
22.05.2025
US CERT
20.05.2025
US CERT (ICS)
20.05.2025

Nach Quelle

Archiv

2025
2024
2023
2022
2021
2020
2019
2018
2017

Feeds