Dienstag, 13.05.2025
Titel
SSA-832273 V1.9 (Last Update: 2025-05-13): Multiple Vulnerabilities in Fortigate NGFW Before V7.4.3 on RUGGEDCOM APE1808 Devices
Veröffentlicht
13. Mai 2025 02:00
Text
Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products. Siemens has released a new version for RUGGEDCOM APE1808 and recommends to update to the latest version. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or ...
Titel
SSA-864900 V1.0: Multiple Vulnerabilities in Fortigate NGFW on RUGGEDCOM APE1808 Devices
Veröffentlicht
13. Mai 2025 02:00
Text
Fortinet has published information on vulnerabilities in FortiOS. This advisory lists the related Siemens Industrial products. Siemens is preparing fix versions and recommends to consult and implement the workarounds provided in Fortinet’s upstream security notifications.
Titel
SSA-770770 V1.3 (Last Update: 2025-05-13): Multiple Vulnerabilities in Fortigate NGFW Before V7.4.7 on RUGGEDCOM APE1808 Devices
Veröffentlicht
13. Mai 2025 02:00
Text
Fortinet has published information on vulnerabilities in FortiOS. This advisory lists the related Siemens Industrial products. Siemens has released a new version for RUGGEDCOM APE1808 and recommends to update to the latest version.
Titel
SSA-767615 V1.3 (Last Update: 2025-05-13): Information Disclosure Vulnerability in SIPROTEC 5 Devices
Veröffentlicht
13. Mai 2025 02:00
Text
An information disclosure vulnerability in SIPROTEC 5 devices could allow an unauthenticated, remote attacker to retrieve sensitive information of the device. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products ...
Titel
SSA-726617 V1.0: Incorrect Privilege Assignment Vulnerability in Mendix OIDC SSO Module
Veröffentlicht
13. Mai 2025 02:00
Text
The Mendix OIDC SSO module grants read and write access to all tokens exclusively to the Administrator role and could result in privilege misuse by an adversary modifying the module during Mendix development. Siemens has released a new version for Mendix OIDC SSO and recommends to update to the latest ...
Titel
SSA-673996 V1.2 (Last Update: 2025-05-13): Buffer Overflow Vulnerability in Third-Party Component in SICAM and SITIPE Products
Veröffentlicht
13. Mai 2025 02:00
Text
Multiple SICAM products are affected by buffer overflow vulnerability in the IEC 61850 Client libraries from Triangle MicroWorks that could allow an unauthenticated remote attacker to create a denial of service condition by sending specially crafted MMS messages. Affected SICAM and SITIPE products: SICAM A8000 Device firmware ET85 for CP-8000/CP-8021/CP-8022 ...
Titel
SSA-928984 V1.2 (Last Update: 2025-05-13): Heap-based Buffer Overflow Vulnerability in User Management Component (UMC)
Veröffentlicht
13. Mai 2025 02:00
Text
Siemens User Management Component (UMC) is affected by a heap-based buffer overflow vulnerability which could allow an unauthenticated remote attacker arbitrary code execution. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures ...
Titel
SSA-935500 V1.3 (Last Update: 2025-05-13): Denial of Service Vulnerability in FTP Server of Nucleus RTOS based APOGEE, TALON and Desigo PXC/PXM Products
Veröffentlicht
13. Mai 2025 02:00
Text
A denial of service vulnerability has been identified in the Nucleus RTOS (real-time operating system) and reported in the Siemens Security Advisory SSA-313313: https://cert-portal.siemens.com/productcert/html/ssa-313313.html. The products listed below use affected versions of the Nucleus software and inherently contain the vulnerability. Siemens has released new versions for several affected products and ...
Titel
SSA-828116 V1.0: Denial of Service Vulnerability in BACnet ATEC Devices
Veröffentlicht
13. Mai 2025 02:00
Text
BACnet ATEC devices are affected by a denial of service vulnerability that could be triggered by an attacker residing in the same BACnet network by sending a specially crafted MSTP message. A power cycle is required to restore the device’s normal operation. Siemens recommends countermeasures for products where fixes are ...
Titel
SSA-819629 V1.2 (Last Update: 2025-05-13): Weak Authentication Vulnerability in Industrial Edge Device Kit
Veröffentlicht
13. Mai 2025 02:00
Text
Users of Industrial Edge Devices are advised to consult the respective Security Advisories for their devices (for Siemens Industrial Edge devices see Additional Information). Industrial Edge Device Kit contains a weak authentication vulnerability that could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Industrial Edge ...
Titel
SSA-794185 V1.0: RADIUS Protocol Susceptible to Forgery Attacks (CVE-2024-3596) - Impact to SIPROTEC, SICAM and Related Products
Veröffentlicht
13. Mai 2025 02:00
Text
This advisory documents the impact of CVE-2024-3596 (also dubbed “Blastradius”), a vulnerability in the RADIUS protocol, to SIPROTEC, SICAM and related products. The vulnerability could allow on-path attackers, located between a Network Access Server (the RADIUS client, e.g., a SICAM device) and a RADIUS server, to forge Access-Request packets in ...
Montag, 12.05.2025
Titel
Russian GRU Targeting Western Logistics Entities and Technology Companies
Veröffentlicht
12. Mai 2025 18:49
Text
Executive Summary This joint cybersecurity advisory (CSA) highlights a Russian state-sponsored cyber campaign targeting Western logistics entities and technology companies. This includes those involved in the coordination, transport, and delivery of foreign assistance to Ukraine. Since 2022, Western logistics entities and IT companies have faced an elevated risk of targeting ...
Donnerstag, 08.05.2025
Titel
Mitsubishi Electric CC-Link IE TSN
Veröffentlicht
8. Mai 2025 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.2 ATTENTION: Exploitable remotely Vendor: Mitsubishi Electric Equipment: CC-Link IE TSN Remote I/O module, CC-Link IE TSN Analog-Digital Converter module, CC-Link IE TSN Digital-Analog Converter module, CC-Link IE TSN FPGA module, CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY Vulnerability: Improper ...
Dienstag, 06.05.2025
Titel
BrightSign Players
Veröffentlicht
6. Mai 2025 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: BrightSign Equipment: Brightsign Players Vulnerabilities: Execution with Unnecessary Privileges 2. RISK EVALUATION Successful exploitation of this vulnerability could allow for privilege escalation on the device, easily guessed passwords, or for arbitrary code to be executed on ...
Titel
Optigo Networks ONS NC600
Veröffentlicht
6. Mai 2025 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Optigo Networks Equipment: ONS NC600 Vulnerability: Use of Hard-coded Credentials 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to establish an authenticated connection with the hard-coded credentials and perform OS command executions. ...
Titel
Milesight UG65-868M-EA
Veröffentlicht
6. Mai 2025 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 6.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Milesight Equipment: UG65-868M-EA Vulnerability: Improper Access Control for Volatile Memory Containing Boot Code 2. RISK EVALUATION Successful exploitation of this vulnerability could allow any user with admin privileges to inject arbitrary shell commands. 3. TECHNICAL DETAILS ...
Donnerstag, 01.05.2025
Titel
KUNBUS GmbH Revolution Pi
Veröffentlicht
1. Mai 2025 14:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: KUNBUS Equipment: Revolution Pi Vulnerabilities: Missing Authentication for Critical Function, Authentication Bypass by Primary Weakness, Improper Neutralization of Server-Side Includes (SSI) Within a Web Page 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow attackers ...
  • 1
  • 2
  • 3 (current)

Letzte Updates

BOSCH PSIRT
25.04.2025
SIEMENS CERT
14.05.2025
US CERT
20.05.2025