SIEMENS CERT
01/13/2026
Siemens ET 200SP contains a denial-of-service vulnerability that could be triggered by sending a valid S7 protocol Disconnect Request (COTP DR TPDU), causing the device to become unresponsive and require a power cycle to recover. Siemens has released new versions for several affected products and recommends to update to the …
SIEMENS CERT
01/13/2026
Devices based on RUGGEDCOM ROX before V2.17 contain multiple high severity vulnerabilities. Siemens has released a new version for RUGGEDCOM ROX II family and recommends to update to the latest version.
SIEMENS CERT
01/13/2026
Siemens User Management Component (UMC) is affected by a heap-based buffer overflow vulnerability which could allow an unauthenticated remote attacker arbitrary code execution. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are not, …
SIEMENS CERT
01/13/2026
Fortinet has published information on vulnerabilities in FortiOS. This advisory lists the related Siemens Industrial products. Siemens is preparing fix versions and recommends to consult and implement the workarounds provided in Fortinet’s upstream security notifications.
SIEMENS CERT
12/12/2025
Siemens Simcenter Femap versions before V2512 are affected by uninitialized memory vulnerability that could be triggered when the application reads files in SLDPRT format. If a user is tricked to open a malicious file with the affected application, an attacker could leverage the vulnerability to perform remote code execution in …
SIEMENS CERT
12/09/2025
The openSSL component, versions 3.0.0 through 3.0.6, contains two buffer overflow vulnerabilities (CVE-2022-3602, CVE-2022-3786) in the X.509 certificate verification [0]. They could allow an attacker to create a denial of service condition or execute arbitrary code on a vulnerable TLS server (if the server requests client certificate authentication), or on …
SIEMENS CERT
12/09/2025
Affected products do not properly restrict access permissions to a local Windows Named Pipe and do not properly sanitize user-controllable input sent to that Named Pipe. This could allow a local authenticated attacker to cause a type confusion and execute arbitrary code within the affected application and its privileges. Siemens …
SIEMENS CERT
12/09/2025
Multiple Siemens products are affected by improper certificate validation in Siemens Advanced Licensing (SALT) Toolkit. This could allow an unauthenticated remote attacker to perform man in the middle attacks. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures for …