Dezember 2020
Titel
SSA-312271 V1.4 (Last Update: 2020-12-08): Unquoted Search Path Vulnerabilities in Windows-based Industrial Software Applications
Veröffentlicht
8. Dezember 2020 01:00
Text
The latest update for affected products fix local privilege escalation vulnerabilities that could allow authorized local users with administrative privileges to execute custom code with SYSTEM level privileges. Siemens has released updates for some of the affected products, and is working on further updates. For the remaining affected products, Siemens ...
Titel
SSA-181018 V1.6 (Last Update: 2020-12-08): Heap Overflow Vulnerability in SCALANCE X switches, RUGGEDCOM Win, RFID 181EIP, and SIMATIC RF182C
Veröffentlicht
8. Dezember 2020 01:00
Text
SCALANCE X switches, RUGGEDCOM Win, RFID 181EIP, and SIMATIC RF182C are affected by a vulnerability that could allow an unprivileged attacker located in the same local network segment (OSI Layer 2) to gain system privileges by sending a specially crafted DHCP response to a client’s DHCP request. Siemens has released ...
Titel
SSA-102233 V1.3 (Last Update: 2020-12-08): SegmentSmack in VxWorks-based Industrial Devices
Veröffentlicht
8. Dezember 2020 01:00
Text
The products listed below contain a vulnerability that could allow remote attackers to affect the availability of the devices under certain conditions. The underlying TCP stack can be forced to make very computation expensive calls for every incoming packet which can lead to a Denial-of-Service. Siemens is working on software ...
Titel
SSA-102144 V1.1 (Last Update: 2020-12-08): Code Execution Vulnerability in LOGO! Soft Comfort
Veröffentlicht
8. Dezember 2020 01:00
Text
A vulnerability was identified in LOGO! Soft Comfort. The vulnerability could allow an attacker to execute arbitrary code if the attacker tricks a legitimate user to open a manipulated project. Siemens has released an update for the LOGO! Soft Comfort and recommends that customers update to the latest version.
Titel
SSA-87240 V1.2 (Last Update: 2020-12-08): Vulnerabilities in SIEMENS LOGO!
Veröffentlicht
8. Dezember 2020 01:00
Text
Two vulnerabilities have been identified in SIEMENS LOGO!8 BM devices. The most severe vulnerability could allow an attacker to hijack existing web sessions. Siemens has released updates for the affected products and recommends that customers update to the latest version.
Titel
SSA-712690 V1.0: Vulnerabilities in XHQ Operations Intelligence
Veröffentlicht
8. Dezember 2020 01:00
Text
Multiple vulnerabilities have been identified in the XHQ Operations Intelligence product line. These vulnerabilities could allow for data injection in the XHQ’s web interfaces. Siemens recommends to update XHQ Operations Intelligence product line to the newest version.
Titel
SSA-700697 V1.0: Denial-of-Service Vulnerability in Web Server of SIMATIC Controllers
Veröffentlicht
8. Dezember 2020 01:00
Text
SIMATIC ET 200SP Open Controller V20.8 and SIMATIC S7-1500 Software Controller V20.8 are affected by a denial-of-service vulnerability in the web server. Siemens has released updates for the affected products and recommends to update to the latest version.
Titel
SSA-541017 V1.0: Embedded TCP/IP Stack Vulnerabilities (AMNESIA:33) in SIRIUS 3RW5 Modbus TCP and SENTRON PAC Devices
Veröffentlicht
8. Dezember 2020 01:00
Text
Recently security researchers discovered and disclosed 33 vulnerabilities in several open-source TCP/IP stacks for embedded devices, also known as “AMNESIA:33” vulnerabilities. The Siemens products mentioned below are affected by one of these vulnerabilities (CVE-2020-13988). Siemens has released updates for SENTRON PAC devices, is working on updates for SIRIUS 3RW5 communication ...
Titel
SSA-480824 V1.0: Multiple Vulnerabilities in LOGO! 8 BM
Veröffentlicht
8. Dezember 2020 01:00
Text
The latest update for LOGO! 8 BM fixes multiple vulnerabilities. The most severe could allow an attacker with network access to gain full control over the device. Siemens has released updates for the affected products and recommends that customers update to the latest version.
Titel
SSA-478893 V1.0: TightVNC Vulnerabilities in Industrial Products
Veröffentlicht
8. Dezember 2020 01:00
Text
Multiple TightVNC (V1.x) vulnerabilities in the affected products could allow remote code execution and Denial-of-Service attacks under certain conditions. Siemens has released updates for several affected products, is working on updates for the remaining affected products and recommends specific countermeasures until fixes are available.
Titel
SSA-415783 V1.0: Insecure SSL configuration in SICAM A8000 CP-8000, CP-8021 and CP-8022
Veröffentlicht
8. Dezember 2020 01:00
Text
Some firmware versions of the affected products use outdated and insecure ciphers or can be downgraded to use outdated and insecure ciphers.
Titel
SSA-087240 V1.2 (Last Update: 2020-12-08): Vulnerabilities in SIEMENS LOGO!
Veröffentlicht
8. Dezember 2020 01:00
Text
Two vulnerabilities have been identified in SIEMENS LOGO!8 BM devices. The most severe vulnerability could allow an attacker to hijack existing web sessions. Siemens has released updates for the affected products and recommends that customers update to the latest version.
Titel
SSA-841348 V1.4 (Last Update: 2020-12-08): Multiple Vulnerabilities in the UMC Stack
Veröffentlicht
8. Dezember 2020 01:00
Text
The latest update for the below listed products fixes two security vulnerabilities that could allow an attacker to cause a partial Denial-of-Service on the UMC component of the affected devices under certain circumstances, and one vulnerability that could allow an attacker to locally escalate privileges from a user with administrative ...
Titel
SSA-817401 V1.1 (Last Update: 2020-12-08): Missing Authentication Vulnerability in SIEMENS LOGO!
Veröffentlicht
8. Dezember 2020 01:00
Text
A missing authentication vulnerability has been identified in SIEMENS LOGO!8 BM devices. The vulnerability could lead to an attacker reading and modifying the device configuration and obtain project files from the devices if the attacker has access to port 135/tcp.
Titel
SSA-780073 V1.6 (Last Update: 2020-12-08): Denial-of-Service Vulnerability in PROFINET Devices via DCE-RPC Packets
Veröffentlicht
8. Dezember 2020 01:00
Text
Products that include the Siemens PROFINET-IO (PNIO) stack in versions prior V06.00 are potentially affected by a denial-of-service vulnerability when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. Siemens has released updates for several affected products and recommends to update to the new versions. Siemens is preparing ...
Titel
SSA-712518 V1.1 (Last Update: 2020-12-08): Information Disclosure Vulnerability (Kr00k) in Industrial Wi-Fi Products
Veröffentlicht
8. Dezember 2020 01:00
Text
An information disclosure vulnerability (CVE-2019-15126, also known as Kr00k) could allow an attacker to read a discrete set of traffic over the air after a Wi-Fi device state change. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available.
Titel
SSA-689942 V1.2 (Last Update: 2020-12-08): Denial-of-Service and DLL Hijacking Vulnerabilities in Multiple SIMATIC Software Products
Veröffentlicht
8. Dezember 2020 01:00
Text
Multiple SIMATIC Software products are affected by two vulnerabilities that could allow an attacker to manipulate project files that may lead to Remote Code Execution or Denial-of-Service attacks. Siemens has released updates to some of the affected products and recommends that customers update to the latest version. Siemens is preparing ...
Titel
SSA-616472 V1.7 (Last Update: 2020-12-08): ZombieLoad and Microarchitectural Data Sampling Vulnerabilities in Industrial Products
Veröffentlicht
8. Dezember 2020 01:00
Text
Security researchers published information on vulnerabilities known as ZombieLoad and Microarchitectural Data Sampling (MDS). These vulnerabilities affect many modern processors from different vendors to a varying degree. Several Siemens Industrial Products contain processors that are affected by the vulnerabilities.
Titel
SSA-542701 V1.2 (Last Update: 2020-12-08): Vulnerabilities in SIEMENS LOGO!
Veröffentlicht
8. Dezember 2020 01:00
Text
Multiple vulnerabilities have been identified in SIEMENS LOGO!8 BM devices. The most severe vulnerability could lead to an attacker reading and modifying the device configuration if the attacker has access to port 10005/tcp. Siemens has released an update for the LOGO! 8 BM (incl. SIPLUS variants) and recommends that customers ...
Titel
SSA-542525 V1.2 (Last Update: 2020-12-08): Authentication Vulnerabilities in SIMATIC HMI Products
Veröffentlicht
8. Dezember 2020 01:00
Text
SIMATIC HMI Products are affected by two vulnerabilities that could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available.
Titel
SSA-534763 V1.2 (Last Update: 2020-12-08): Special Register Buffer Data Sampling (SRBDS) aka Crosstalk in Industrial Products
Veröffentlicht
8. Dezember 2020 01:00
Text
Security researchers published information on a vulnerability known as Crosstalk (INTEL-SA-00320). This vulnerability affects modern Intel processors to a varying degree. Several Siemens Industrial Products contain processors that are affected by the vulnerability. Siemens is preparing updates and recommends specific countermeasures until fixes are available.
November 2020
Titel
SSA-492828 (Last Update: 2020-11-10): Denial-of-Service Vulnerability in SIMATIC S7-300 CPUs and SINUMERIK Controller
Veröffentlicht
10. November 2020 01:00
Text
A vulnerability in S7-300 might allow an attacker to cause a Denial-of-Service condition on port 102 of the affected devices by sending specially crafted packets. Siemens is preparing updates and recommends specific countermeasures until fixes are available.
Titel
SSA-431802 (Last Update: 2020-11-10): Multiple Vulnerabilities in SCALANCE W1750D
Veröffentlicht
10. November 2020 01:00
Text
Siemens SCALANCE W1750D is a brandlabled device. Aruba has released a related security advisory (ARUBA-PSA-2016-004) [0] disclosing vulnerabilities in its Aruba Instant product line. The advisory contains multiple related vulnerabilities that are summarized in CVE-2016-2031. This advisory is a reminder to customers that the PAPI protocol is not a secure ...
Titel
SSB-439005 (Last Update: 2020-11-10): Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP
Veröffentlicht
10. November 2020 01:00
Text
Titel
SSA-841348 (Last Update: 2020-11-10): Multiple Vulnerabilities in the UMC Stack
Veröffentlicht
10. November 2020 01:00
Text
The latest update for the below listed products fixes two security vulnerabilities that could allow an attacker to cause a partial Denial-of-Service on the UMC component of the affected devices under certain circumstances, and one vulnerability that could allow an attacker to locally escalate privileges from a user with administrative ...

Letzte Updates

BOSCH PSIRT
31.10.2024
SIEMENS CERT
22.11.2024
US CERT
08.11.2024
US CERT (ICS)
21.11.2024

Nach Quelle

Archiv

2024
2023
2022
2021
2020
2019
2018
2017

Feeds