September 2021
Titel
SSA-865327 V1.1 (Last Update: 2021-09-14): Incorrect Authorization Vulnerability in Industrial Products
Veröffentlicht
14. September 2021 02:00
Text
The latest updates for the below mentioned products fix a vulnerability that allows an unauthenticated attacker to read PLC variables from affected devices without proper authentication under certain circumstances. Siemens has released updates for some of the affected products, is working on updates for the remaining affected products and recommends ...
Titel
SSA-830194 V1.1 (Last Update: 2021-09-14): Missing Authentication Vulnerability in S7-1200 Devices
Veröffentlicht
14. September 2021 02:00
Text
SIMATIC S7-1200 PLC, version V4.5.0 fails to authenticate against configured passwords when the affected device was provisioned using TIA Portal V13. This could allow an attacker using TIA Portal V13 or later versions to bypass authentication and download arbitrary programs to the PLC. Siemens has released an update for SIMATIC ...
Titel
SSA-789208 V1.1 (Last Update: 2021-09-14): Multiple Vulnerabilities (INFRA:HALT) in Interniche IP-Stack based Low Voltage Devices
Veröffentlicht
14. September 2021 02:00
Text
Security researchers discovered and disclosed 14 vulnerabilities in the Interniche IP stack, also known as “INFRA:HALT” vulnerabilities [0]. This advisory describes the impact to Siemens low voltage products, which are only affected by four out of the 14 vulnerabilities. Siemens has released updates for several affected products and recommends to ...
Titel
SSA-780073 V1.8 (Last Update: 2021-09-14): Denial-of-Service Vulnerability in PROFINET Devices via DCE-RPC Packets
Veröffentlicht
14. September 2021 02:00
Text
Products that include the Siemens PROFINET-IO (PNIO) stack in versMions prior V06.00 are potentially affected by a denial-of-service vulnerability when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. Siemens has released updates for several affected products and recommends to update to the new versions. Siemens is preparing ...
Titel
SSA-772220 V1.2 (Last Update: 2021-09-14): OpenSSL Vulnerabilities in Industrial Products
Veröffentlicht
14. September 2021 02:00
Text
OpenSSL has published a security advisory [0] about a vulnerability in OpenSSL versions 1.1.1 < 1.1.1k, that allows an unauthenticated attacker to cause a Denial-of-Service (DoS) if a maliciously crafted renegotiation message is sent. Siemens is preparing updates and recommends countermeasures for products where updates are not, or not yet ...
Titel
SSA-756744 V1.1 (Last Update: 2021-09-14): OS Command Injection Vulnerability in SINEC NMS
Veröffentlicht
14. September 2021 02:00
Text
The latest update for SINEC NMS fixes a vulnerability that could allow an authenticated remote attacker to execute arbitrary code on the system, with system privileges, under certain conditions. Siemens has released an update for SINEC NMS and recommends to update to the latest version.
Titel
SSA-661034 V1.1 (Last Update: 2021-09-14): Incorrect Permission Assignment in Multiple SIMATIC Software Products
Veröffentlicht
14. September 2021 02:00
Text
Multiple SIMATIC software products are affected by a vulnerability that could allow an attacker to change the content of certain metafiles and subsequently manipulate parameters or behaviour of devices configured by the affected software products. Siemens has released updates for several affected products and recommends to update to the latest ...
Titel
SSA-599968 V1.2 (Last Update: 2021-09-14): Denial-of-Service Vulnerability in Profinet Devices
Veröffentlicht
14. September 2021 02:00
Text
A vulnerability in affected devices could allow an attacker to perform a denial-of-service attack if a large amount of Profinet Discovery and Configuration Protocol (DCP) reset packets is sent to the affected devices. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens ...
Titel
SSA-538778 V1.1 (Last Update: 2021-09-14): SmartVNC Vulnerabilities in SIMATIC HMI/WinCC Products
Veröffentlicht
14. September 2021 02:00
Text
Multiple SmartVNC vulnerabilities in the affected products listed below could allow remote code execution and Denial-of-Service attacks under certain conditions. Siemens has released updates for the affected products and recommends to update to the latest version.
Titel
SSA-462066 V2.5 (Last Update: 2021-09-14): Vulnerability known as TCP SACK PANIC in Industrial Products
Veröffentlicht
14. September 2021 02:00
Text
Multiple industrial products are affected by a vulnerability in the kernel known as TCP SACK PANIC. The vulnerability could allow a remote attacker to cause a denial of service condition. Siemens has released updates for several affected products and recommends to update to the new versions. Siemens is preparing further ...
Titel
SSB-439005 V3.7 (Last Update: 2021-09-14): Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP
Veröffentlicht
14. September 2021 02:00
Text
Titel
SSA-434536 V1.1 (Last Update: 2021-09-14): Memory Protection Bypass Vulnerability in SINUMERIK ONE and SINUMERIK MC
Veröffentlicht
14. September 2021 02:00
Text
SINUMERIK ONE and SINUMERIK MC products are affected by a memory protection bypass vulnerability in the integrated S7-1500 CPU that could allow an attacker to write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks on the CPU. Siemens has released updates for ...
Titel
SSA-434535 V1.1 (Last Update: 2021-09-14): Memory Protection Bypass Vulnerability in SINAMICS PERFECT HARMONY GH180 Drives
Veröffentlicht
14. September 2021 02:00
Text
Several models of SINAMICS PERFECT HARMONY GH180 Drives are affected by a memory protection bypass vulnerability in the integrated S7-1500 or S7-1200 CPU that could allow an attacker to write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks on the CPU. Siemens ...
Titel
SSA-434534 V1.1 (Last Update: 2021-09-14): Memory Protection Bypass Vulnerability in SIMATIC S7-1200 and S7-1500 CPU Families
Veröffentlicht
14. September 2021 02:00
Text
SIMATIC S7-1200 and S7-1500 CPU products contain a memory protection bypass vulnerability that could allow an attacker to write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks. Siemens has released updates for several affected products and strongly recommends to update to the ...
Titel
SSA-428051 V1.1 (Last Update: 2021-09-14): Privilege Escalation Vulnerability in TIA Administrator
Veröffentlicht
14. September 2021 02:00
Text
The latest update for TIA Administrator, installed together with TIA Portal and PCS neo, fixes a privilege escalation vulnerability that could allow local users to escalate privileges and execute code as local SYSTEM user. Siemens has released updates for the affected products and recommends to update to the latest versions.
Titel
SSA-324955 V1.4 (Last Update: 2021-09-14): SAD DNS Attack in Linux Based Products
Veröffentlicht
14. September 2021 02:00
Text
A vulnerability made public under the name SAD DNS affects Domain Name System resolvers due to a vulnerability in the Linux kernel when handling ICMP packets. The Siemens products which are affected are listed below. For more information please see https://www.saddns.net/. Siemens has released updates for several affected products and ...
Titel
SSA-312271 V1.8 (Last Update: 2021-09-14): Unquoted Search Path Vulnerabilities in Windows-based Industrial Software Applications
Veröffentlicht
14. September 2021 02:00
Text
Several industrial products as listed below contain a local privilege escalation vulnerabilities that could allow authorized local users with administrative privileges to execute custom code with SYSTEM level privileges. Siemens has released updates for the affected products and recommends to update to the latest versions.
Titel
SSA-274900 V1.2 (Last Update: 2021-09-14): Use of hardcoded key in Scalance X devices under certain conditions
Veröffentlicht
14. September 2021 02:00
Text
Scalance X devices might not generate a unique random key after factory reset, and use a private key shipped with the firmware Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends specific countermeasures for products where ...
Titel
SSA-187092 V1.1 (Last Update: 2021-09-14): Several Buffer-Overflow Vulnerabilities in Web Server of SCALANCE X-200
Veröffentlicht
14. September 2021 02:00
Text
Several SCALANCE X-200 switches contain buffer overflow vulnerabilities in the web server. In the most severe case an attacker could potentially remotely execute code. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available.
Titel
SSA-139628 V1.2 (Last Update: 2021-09-14): Vulnerabilities in Web Server for Scalance X Products
Veröffentlicht
14. September 2021 02:00
Text
Several SCALANCE X switches contain vulnerabilities in the web server of the affected devices. An unauthenticated attacker could reboot, cause denial-of-service conditions and potentially impact the system by other means through heap and buffer overflow vulnerabilities. Siemens has released updates for several affected products and recommends to update to the ...
Titel
SSA-102233 V1.6 (Last Update: 2021-09-14): SegmentSmack in VxWorks-based Industrial Devices
Veröffentlicht
14. September 2021 02:00
Text
The products listed below contain a vulnerability that could allow remote attackers to affect the availability of the devices under certain conditions. The underlying TCP stack can be forced to make very computation expensive calls for every incoming packet which can lead to a Denial-of-Service. Siemens has released an update ...
Titel
SSA-100232 V1.3 (Last Update: 2021-09-14): Denial-of-Service vulnerability in SCALANCE X Switches
Veröffentlicht
14. September 2021 02:00
Text
A vulnerability in several SCALANCE X devices could allow an unauthenticated attacker with network access to an affected device to perform a denial-of-service. Siemens has released an update for SCALANCE X-200IRT and recommends to update to the latest version. Siemens recommends specific countermeasures for products where updates are not, or ...
Titel
SSA-997732 V1.0: Modfem File Parsing Vulnerability in Simcenter Femap before V2021.2
Veröffentlicht
14. September 2021 02:00
Text
Siemens Simcenter Femap is affected by a vulnerability that could be triggered when the application reads modfem files. If a user is tricked to open a malicious file with the affected application, an attacker could leverage this vulnerability to leak information in the context of the current process. Siemens recommends ...
Titel
SSA-987403 V1.0: Multiple Vulnerabilities in Teamcenter
Veröffentlicht
14. September 2021 02:00
Text
Teamcenter is affected by three vulnerabilities namely incorrect privilege assignment, Insecure Direct Object Reference (IDOR) and XML External Entity Injection (XXE). Siemens has released updates for the affected products and recommends to update to the latest versions.
Titel
SSA-944498 V1.0: Buffer Overflow Vulnerability in Web Server of APOGEE and TALON Automation Devices
Veröffentlicht
14. September 2021 02:00
Text
A buffer overflow vulnerability in the integrated web server of multiple APOGEE and TALON automation devices could allow a remote attacker to execute arbitrary code on the devices with root privileges. Affected devices include the APOGEE MBC/MEC/PXC P2 Ethernet devices with Power Open Processors (PPC), APOGEE PXC BACnet devices, and ...

Letzte Updates

BOSCH PSIRT
14.08.2025
SIEMENS CERT
16.09.2025
US CERT
25.08.2025
US CERT (ICS)
16.09.2025

Nach Quelle

Archiv

2025
2024
2023
2022
2021
2020
2019
2018
2017

Feeds