Januar 2025
Titel
Schneider Electric Harmony HMI and Pro-face HMI Products
Veröffentlicht
10. Januar 2025 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: Harmony HMI and Pro-face HMI Products Vulnerability: Use of Unmaintained Third-Party Components 2. RISK EVALUATION Successful exploitation of this vulnerability could cause complete control of the device when an authenticated user installs malicious ...
Titel
Schneider Electric PowerChute Serial Shutdown
Veröffentlicht
10. Januar 2025 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 6.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: PowerChute Serial Shutdown Vulnerability: Improper Authentication 2. RISK EVALUATION Successful exploitation of this vulnerability could cause a denial of access to the web interface when someone on the local network repeatedly requests the ...
Titel
Nedap Librix Ecoreader
Veröffentlicht
7. Januar 2025 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/Low attack complexity Vendor: Nedap Librix Equipment: Ecoreader Vulnerability: Missing Authentication for Critical Function 2. RISK EVALUATION Successful exploitation of this vulnerability could result in remote code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Ecoreader are ...
Titel
ABB ASPECT-Enterprise, NEXUS, and MATRIX Series Products
Veröffentlicht
7. Januar 2025 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: ABB Equipment: ASPECT-Enterprise, NEXUS, and MATRIX series Vulnerabilities: Files or Directories Accessible to External Parties, Improper Validation of Specified Type of Input, Cleartext Transmission of Sensitive Information, Cross-site Scripting, Server-Side Request Forgery (SSRF), Improper Neutralization of ...
Dezember 2024
Titel
Tibbo AggreGate Network Manager
Veröffentlicht
19. Dezember 2024 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Tibbo Equipment: AggreGate Network Manager Vulnerability: Unrestricted Upload of File with Dangerous Type 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to achieve code execution on the affected device. 3. TECHNICAL DETAILS ...
Titel
Hitachi Energy RTU500 series CMU
Veröffentlicht
19. Dezember 2024 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 5.9 ATTENTION: Exploitable remotely Vendor: Hitachi Energy Equipment: RTU500 series CMU Vulnerability: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 ...
Titel
Delta Electronics DTM Soft
Veröffentlicht
19. Dezember 2024 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.5 ATTENTION: Low attack complexity Vendor: Delta Electronics Equipment: DTM Soft Vulnerability: Deserialization of Untrusted Data 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to execute arbitrary code. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Delta Electronics products ...
Titel
Siemens User Management Component
Veröffentlicht
19. Dezember 2024 13:00
Text
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS ...
Titel
Hitachi Energy SDM600
Veröffentlicht
19. Dezember 2024 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 8.0 ATTENTION: Exploitable from adjacent network Vendor: Hitachi Energy Equipment: SDM600 Vulnerabilities: Origin Validation Error, Incorrect Authorization 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to escalate privileges and access sensitive information. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Hitachi ...
Titel
Schneider Electric Accutech Manager
Veröffentlicht
19. Dezember 2024 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: Accutech Manager Vulnerability: Classic Buffer Overflow 2. RISK EVALUATION Successful exploitation could allow an attacker to cause a crash of the Accutech Manager when receiving a specially crafted request over port 2536/TCP. 3. ...
Titel
Hitachi Energy TropOS Devices Series 1400/2400/6400
Veröffentlicht
17. Dezember 2024 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 5.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Hitachi Energy Equipment: TropOS Devices Series 1400/2400/6400 Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following ...
Titel
Schneider Electric Modicon
Veröffentlicht
17. Dezember 2024 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: Modicon M241 / M251 / M258 / LMC058 Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could lead to a denial-of-service and a loss of confidentiality and integrity in ...
Titel
Rockwell Automation PowerMonitor 1000 Remote
Veröffentlicht
17. Dezember 2024 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: PowerMonitor 1000 Remote Vulnerabilities: Unprotected Alternate Channel, Heap-based Buffer Overflow, Classic Buffer Overflow 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to perform edit operations, create admin users, perform ...
Titel
ThreatQuotient ThreatQ Platform
Veröffentlicht
17. Dezember 2024 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: ThreatQuotient Inc. Equipment: ThreatQ Platform Vulnerability: Command Injection 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to perform remote code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of ThreatQuotient ...
Titel
Siemens CPCI85 Central Processing/Communication
Veröffentlicht
12. Dezember 2024 13:00
Text
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS ...
Titel
Siemens Solid Edge SE2024
Veröffentlicht
12. Dezember 2024 13:00
Text
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS ...
Titel
Siemens SENTRON Powercenter 1000
Veröffentlicht
12. Dezember 2024 13:00
Text
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY ...
Titel
Siemens Teamcenter Visualization
Veröffentlicht
12. Dezember 2024 13:00
Text
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS ...
Titel
Schneider Electric EcoStruxure Foxboro DCS Core Control Services
Veröffentlicht
10. Dezember 2024 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low Attack Complexity Vendor: Schneider Electric Equipment: EcoStruxure Foxboro DCS Core Control Services Vulnerabilities: Out-of-bounds Write, Improper Validation of Array Index, Improper Input Validation 2. RISK EVALUATION Successful exploitation of these vulnerabilities could lead to a loss of system functionality or ...
Titel
MOBATIME Network Master Clock
Veröffentlicht
10. Dezember 2024 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/Low attack complexity Vendor: MOBATIME Equipment: Network Master Clock - DTS 4801 Vulnerability: Use of Default Credentials 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to take control of the operating system for this product. 3. ...
Titel
Schneider Electric FoxRTU Station
Veröffentlicht
10. Dezember 2024 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.3 ATTENTION: Low Attack Complexity Vendor: Schneider Electric Equipment: FoxRTU Station Vulnerability: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to perform remote code execution. 3. TECHNICAL DETAILS ...
Titel
Rockwell Automation Arena (Update A)
Veröffentlicht
10. Dezember 2024 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.5 ATTENTION: Low attack complexity Vendor: Rockwell Automation Equipment: Arena Vulnerabilities: Use After Free, Out-of-bounds Write, Improper Initialization, Out-of-bounds Read, Dependency on Vulnerable Third-Party Component 2. RISK EVALUATION Successful exploitation of these vulnerabilities could result in execution of arbitrary code. 3. TECHNICAL DETAILS ...
Titel
AutomationDirect C-More EA9 Programming Software
Veröffentlicht
5. Dezember 2024 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.4 ATTENTION: Low attack complexity Vendor: AutomationDirect Equipment: C-More EA9 Programming Software Vulnerabilities: Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of these vulnerabilities could result in memory corruption; a buffer overflow condition may allow remote code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED ...
Titel
Planet Technology Planet WGS-804HPT
Veröffentlicht
5. Dezember 2024 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/Low attack complexity Vendor: Planet Technology Equipment: Planet WGS-804HPT Vulnerabilities: Stack-based Buffer Overflow, Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Integer Underflow (Wrap or Wraparound) 2. RISK EVALUATION Successful exploitation of these vulnerabilities could ...
Titel
ICONICS and Mitsubishi Electric GENESIS64 Products
Veröffentlicht
3. Dezember 2024 13:00
Text
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.5 ATTENTION: Low attack complexity Vendor: ICONICS, Mitsubishi Electric Equipment: ICONICS GENESIS64 Product Suite and Mitsubishi Electric MC Works64 Vulnerabilities: Uncontrolled Search Path Element, Dead Code 2. RISK EVALUATION Successful exploitation of these vulnerabilities could result in remote code execution. 3. TECHNICAL DETAILS ...

Letzte Updates

BOSCH PSIRT
15.01.2025
SIEMENS CERT
14.04.2025
US CERT
01.04.2025
US CERT (ICS)
15.04.2025

Nach Quelle

Archiv

2025
2024
2023
2022
2021
2020
2019
2018
2017

Feeds