April 2023
Title
SSA-382653 V1.2 (Last Update: 2023-04-11): Multiple Denial of Service Vulnerabilities in Industrial Products
Published
April 11, 2023, 2 a.m.
Summary
Affected SIMATIC firmware contains multiple vulnerabilities that could allow an unauthenticated attacker to perform a denial-of-service attack under certain conditions. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends countermeasures for products where updates are not, ...
Title
SSA-244969 V2.0 (Last Update: 2023-04-11): OpenSSL Vulnerability in Industrial Products
Published
April 11, 2023, 2 a.m.
Summary
OpenSSL has published a security advisory [0] about a vulnerability in OpenSSL versions 1.1.1 < 1.1.1l and 1.0.2 < 1.0.2za that allows an attacker to cause a denial of service (DoS) or to disclose private memory content. Siemens has released updates for several affected products and recommends to update to ...
Title
SSA-116924 V1.0: Path Traversal Vulnerability in TIA Portal
Published
April 11, 2023, 2 a.m.
Summary
TIA Portal contains a path traversal vulnerability that could allow the creation or overwrite of arbitrary files in the engineering system. If the user is tricked to open a malicious PC system configuration file, an attacker could exploit this vulnerability to achieve arbitrary code execution. Siemens has released an update ...
Title
SSA-787941 V1.2 (Last Update: 2023-04-11): Denial of Service Vulnerability in RUGGEDCOM ROS V4
Published
April 11, 2023, 2 a.m.
Summary
RUGGEDCOM ROS-based V4 devices are vulnerable to a denial of service attack (Slowloris). By sending partial HTTP requests nonstop, with none completed, the affected web servers will be waiting for the completion of each request, occupying all available HTTP connections. The web server recovers by itself once the attack ends. ...
Title
SSA-472454 V1.0: Command Injection Vulnerability in CPCI85 Firmware of SICAM A8000 Devices
Published
April 11, 2023, 2 a.m.
Summary
The CPCI85 firmware of SICAM A8000 CP-8031 and CP-8050 is affected by unauthenticated command injection vulnerability. This could allow an attacker to perfom remote code execution. Siemens has released updates for the affected products and recommends to update to the latest versions.
Title
SSA-478960 V1.3 (Last Update: 2023-04-11): Missing CSRF Protection in the Web Server Login Page of Industrial Controllers
Published
April 11, 2023, 2 a.m.
Summary
The web server login page of affected products does not apply proper origin checking. This could allow authenticated remote attackers to track the activities of other users via a login cross-site request forgery attack.. Siemens has released updates for several affected products and recommends to update to the latest versions. ...
Title
SSA-712929 V1.9 (Last Update: 2023-04-11): Denial of Service Vulnerability in OpenSSL (CVE-2022-0778) Affecting Industrial Products
Published
April 11, 2023, 2 a.m.
Summary
A vulnerability in the openSSL component (CVE-2022-0778, [0]) could allow an attacker to create a denial of service condition by providing specially crafted elliptic curve certificates to products that use a vulnerable version of openSSL. Siemens has released updates for several affected products and recommends to update to the latest ...
Title
SSA-780073 V2.3 (Last Update: 2023-04-11): Denial of Service Vulnerability in PROFINET Devices via DCE-RPC Packets
Published
April 11, 2023, 2 a.m.
Summary
Products that include the Siemens PROFINET-IO (PNIO) stack in versions prior V06.00 are potentially affected by a denial of service vulnerability when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens ...
Title
SSA-710008 V1.3 (Last Update: 2023-04-11): Multiple Web Vulnerabilities in SCALANCE Products
Published
April 11, 2023, 2 a.m.
Summary
SCALANCE devices contain multiple vulnerabilities in MSPS based product lines that could allow authenticated remote attackers to execute custom code or create a XSS situation, as well as unauthenticated remote attackers to create a denial of service condition. Siemens has released updates for several affected products and recommends to update ...
Title
SSA-792594 V1.1 (Last Update: 2023-04-11): Host Header Injection Vulnerability in Polarion ALM
Published
April 11, 2023, 2 a.m.
Summary
Polarion ALM contains a misconfiguration in its default Apache HTTP Server configuration that could allow an attacker to perform host header injection attacks. Siemens has released an update for Polarion ALM and recommends to update to the latest version.
Title
SSA-813746 V1.0: BadAlloc Vulnerabilities in SCALANCE X-200, X-200IRT, and X-300 Switch Families
Published
April 11, 2023, 2 a.m.
Summary
Siemens has released a new firmware version for SCALANCE X-200 and X-200 IRT switches that address Bad Alloc vulnerabilities in the underlying operating system and recommends to update to the latest versions. Siemens recommends countermeasures for products where updates are not, or not yet available.
Title
SSA-838121 V1.3 (Last Update: 2023-04-11): Multiple Denial of Service Vulnerabilities in Industrial Products
Published
April 11, 2023, 2 a.m.
Summary
Affected SIMATIC firmware contains three vulnerabilities that could allow an unauthenticated attacker to perform a denial of service attack under certain conditions. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures for products where updates are not, or not yet ...
Title
SSA-978220 V1.8 (Last Update: 2023-04-11): Denial of Service Vulnerability over SNMP in Multiple Industrial Products
Published
April 11, 2023, 2 a.m.
Summary
Several industrial products are affected by a vulnerability that could allow remote attackers to conduct a denial of service attack by sending specially crafted packets to port 161/udp (SNMP). Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for ...
Title
SSA-840800 V1.3 (Last Update: 2023-04-11): Code Injection Vulnerability in RUGGEDCOM ROS
Published
April 11, 2023, 2 a.m.
Summary
RUGGEDCOM ROS-based devices are vulnerable to a web-based code injection attack. To execute this attack, it is necessary to access the system via the Command Line Interface (CLI). Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products ...
Title
SSA-840188 V1.6 (Last Update: 2023-04-11): Multiple Vulnerabilities in SIMATIC WinCC Affecting Other SIMATIC Software Products
Published
April 11, 2023, 2 a.m.
Summary
Multiple vulnerabilities were found in SIMATIC WinCC that ultimately could allow local or remote attackers to escalate privileges and read, write or delete critical files. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where updates are ...
Title
JTEKT ELECTRONICS Screen Creator Advance 2
Published
April 6, 2023, 2 p.m.
Summary
1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: JTEKT ELECTRONICS CORPORATION Equipment: Screen Creator Advance 2 Vulnerabilities: Out-of-bounds Read, Out-of-bounds Write, Use After Free 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to disclose information or execute arbitrary code. 3. TECHNICAL DETAILS 3.1 ...
Title
Hitachi Energy MicroSCADA System Data Manager SDM600
Published
April 6, 2023, 2 p.m.
Summary
1. EXECUTIVE SUMMARY CVSS v3 9.9 ATTENTION: Exploitable remotely/low attack complexity Vendor: Hitachi Energy Equipment: MicroSCADA System Data Manager SDM600 Vulnerabilities: Unrestricted Upload of File with Dangerous Type, Improper Authorization, Improper Resource Shutdown or Release, Improper Privilege Management 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker ...
Title
JTEKT ELECTRONICS Kostac PLC Programming Software
Published
April 6, 2023, 2 p.m.
Summary
1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: JTEKT ELECTRONICS CORPORATION Equipment: Kostac PLC Programming Software Vulnerabilities: Out-of-bounds Read, Use After Free 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to disclose information or execute arbitrary code. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS ...
Title
Korenix Jetwave
Published
April 6, 2023, 2 p.m.
Summary
1. EXECUTIVE SUMMARY CVSS v3 8.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Korenix Equipment: Jetwave Vulnerabilities: Command Injection, Uncontrolled Resource Consumption 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to gain full access to the underlying operating system of the device or cause a denial-of-service condition. ...
Title
Industrial Control Links ScadaFlex II SCADA Controllers
Published
April 6, 2023, 2 p.m.
Summary
1. EXECUTIVE SUMMARY CVSS v3 9.1 ATTENTION: Exploitable remotely/low attack complexity/public exploits are available Vendor: Industrial Control Links Equipment: ScadaFlex II SCADA Controllers Vulnerability: External Control of File Name or Path 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an authenticated attacker to overwrite, delete, or create files. ...
Title
Nexx Smart Home Device
Published
April 4, 2023, 2 p.m.
Summary
1. EXECUTIVE SUMMARY CVSS v3 8.6 ATTENTION: Exploitable remotely/low attack complexity Vendor: Nexx Equipment: Garage Door Controller, Smart Plug, Smart Alarm Vulnerabilities: Use of Hard-coded Credentials, Authorization Bypass through User-controlled Key, Improper Input Validation, Improper Authentication 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to receive ...
March 2023
Title
Hitachi Energy IEC 61850 MMS-Server
Published
March 30, 2023, 2 p.m.
Summary
1. EXECUTIVE SUMMARY CVSS v3 5.9 ATTENTION: Exploitable remotely Vendor: Hitachi Energy Equipment: IEC 61850 MMS-Server Vulnerability: Improper Resource Shutdown or Release 2. RISK EVALUATION Successful exploitation of this vulnerability could cause products using the IEC 61850 MMS-server communication stack to stop accepting new MMS-client connections. 3. TECHNICAL DETAILS 3.1 ...
Title
SAUTER EY-modulo 5 Building Automation Stations
Published
March 23, 2023, 1 p.m.
Summary
1. EXECUTIVE SUMMARY CVSS v3 8.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: SAUTER Equipment: EY-modulo 5 Building Automation Stations Vulnerabilities: Cross-site Scripting, Cleartext Transmission of Sensitive Information, and Unrestricted Upload of File with Dangerous Type 2. RISK EVALUATION Successful exploitation of these vulnerabilities could lead to privilege escalation, unauthorized execution ...
Title
ProPump and Controls Osprey Pump Controller
Published
March 23, 2023, 1 p.m.
Summary
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity/public exploits are available Vendor: ProPump and Controls, Inc. Equipment: Osprey Pump Controller Vulnerabilities: Insufficient Entropy, Use of GET Request Method with Sensitive Query Strings, Use of Hard-coded Password, OS Command Injection, Cross-site Scripting, Authentication Bypass using an Alternate Path ...
Title
RoboDK
Published
March 23, 2023, 1 p.m.
Summary
1. EXECUTIVE SUMMARY CVSS v3 7.9 ATTENTION: Low attack complexity Vendor: RoboDK Equipment: RoboDK Vulnerability: Incorrect Permission Assignment for Critical Resource 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to escalate privileges, which could allow attackers to write files to the RoboDK directory and achieve code ...

Last Updates

BOSCH PSIRT
25.04.2025
SIEMENS CERT
13.05.2025
US CERT
01.04.2025
US CERT (ICS)
08.05.2025

By Source

Archive

2025
2024
2023
2022
2021
2020
2019
2018
2017

Feeds