September 2024
Title
SSA-097435 V1.1 (Last Update: 2024-09-12): Usernames Disclosure Vulnerability in Mendix Runtime
Published
Sept. 12, 2024, 2 a.m.
Summary
Mendix Runtime contains an observable response discrepancy vulnerability when validating usernames during authentication. This could allow unauthenticated remote attackers to distinguish between valid and invalid usernames. Siemens has released new versions for the affected products and recommends to update to the latest versions.
Title
SSA-427715 V1.0: Stack-Based Buffer Overflow Vulnerability in Tecnomatix Plant Simulation
Published
Sept. 10, 2024, 2 a.m.
Summary
Siemens Tecnomatix Plant Simulation is affected by a stack-based buffer overflow vulnerability that could be triggered when the application reads files in SPP file format. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially ...
Title
SSA-962515 V1.2 (Last Update: 2024-09-10): Out of Bounds Read Vulnerability in Industrial Products
Published
Sept. 10, 2024, 2 a.m.
Summary
Several industrial products contain an out of bounds read vulnerability that could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel, leading to denial of service condition. Siemens has released new versions for several affected products and recommends to update to the ...
Title
SSA-721642 V1.0: Injection Vulnerability in SCALANCE W700 802.11 AX Family Before V2.4
Published
Sept. 10, 2024, 2 a.m.
Summary
Siemens has released new versions for the affected products and recommends to update to the latest versions.
Title
SSA-629254 V1.0: Remote Code Execution Vulnerability in SIMATIC SCADA and PCS 7 systems
Published
Sept. 10, 2024, 2 a.m.
Summary
The products listed below contain a remote code execution vulnerability that could allow an unauthenticated remote attacker to execute arbitrary code with high privileges. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures ...
Title
SSA-446545 V1.0: Impact of RegreSSHion (CVE-2024-6387) in Siemens Industrial Products
Published
Sept. 10, 2024, 2 a.m.
Summary
An OpenSSH vulnerability, known as regreSSHion, affects multiple Siemens industrial products. This security regression vulnerability consists in a race condition which may allow an unauthenticated remote attacker to achieve remote code execution with high impact on the affected system. Siemens has released new versions for several affected products and recommends ...
Title
SSA-955858 V1.2 (Last Update: 2024-09-10): Multiple Vulnerabilities in LOGO! 8 BM Devices
Published
Sept. 10, 2024, 2 a.m.
Summary
LOGO! 8 BM (incl. SIPLUS variants) contains multiple web-related vulnerabilities. These could allow an attacker to execute code remotely, put the device into a denial of service state or retrieve parts of the memory. The vulnerabilities are related to the hardware of the product. Siemens has released new hardware versions ...
Title
SSA-869574 V1.0: Multiple Vulnerabilities in SINEMA Remote Connect Server Before V3.2 SP2
Published
Sept. 10, 2024, 2 a.m.
Summary
SINEMA Remote Connect Server before V3.2 SP2 is affected by multiple vulnerabilities. Siemens has released a new version for SINEMA Remote Connect Client and recommends to update to the latest version.
Title
SSA-783481 V1.2 (Last Update: 2024-09-10): Denial-of-Service Vulnerability in LOGO! 8 BM
Published
Sept. 10, 2024, 2 a.m.
Summary
A Denial-of-Service vulnerability has been identified in LOGO! 8 BM. This vulnerability could allow an attacker to crash a device, if a user is tricked into loading a malicious project file onto an affected device. The vulnerability is related to the hardware of the product. Siemens has released new hardware ...
Title
SSA-753746 V1.4 (Last Update: 2024-09-10): Denial of Service Vulnerabilities in SIMATIC WinCC Affecting Other SIMATIC Software Products
Published
Sept. 10, 2024, 2 a.m.
Summary
Two null point dereference vulnerabilities affect multiple SIMATIC software products. These could allow an attacker to cause a persistent denial of service condition in the RPC Server of these products. Siemens has released new versions for the affected products and recommends to update to the latest versions.
Title
SSA-690517 V1.1 (Last Update: 2024-09-10): Multiple Vulnerabilities in SCALANCE W700 802.11 AX Family
Published
Sept. 10, 2024, 2 a.m.
Summary
SCALANCE W700 802.11 AX Family is affected by multiple vulnerabilities. Siemens recommends countermeasures for products where fixes are not, or not yet available.
Title
SSA-673996 V1.0: Buffer Overflow Vulnerability in Third-Party Component in SICAM and SITIPE Products
Published
Sept. 10, 2024, 2 a.m.
Summary
Multiple SICAM products are affected by buffer overflow vulnerability in the IEC 61850 Client libraries from Triangle MicroWorks that could allow an unauthenticated remote attacker to create a denial of service condition by sending specially crafted MMS messages. Affected SICAM and SITIPE products: SICAM A8000 Device firmware ETI5 for CP-8031/CP-8050 ...
Title
SSA-566905 V1.3 (Last Update: 2024-09-10): Multiple Denial of Service Vulnerabilities in the Webserver of Industrial Products
Published
Sept. 10, 2024, 2 a.m.
Summary
Multiple vulnerabilities in the affected products could allow an unauthorized attacker with network access to the webserver of an affected products to perform a denial of service attack. Siemens has released new versions for the affected products and recommends to update to the latest versions.
Title
SSA-455250 V1.3 (Last Update: 2024-09-10): Multiple Vulnerabilities in Palo Alto Networks Virtual NGFW on RUGGEDCOM APE1808 Devices Before V11.1.2-h3
Published
Sept. 10, 2024, 2 a.m.
Summary
Palo Alto Networks has published [1] information on vulnerabilities in PAN-OS. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens has released a new version of Palo Alto Networks Virtual NGFW for RUGGEDCOM APE1808 and recommends to update to the latest version. Customers are advised to ...
Title
SSA-844582 V1.1 (Last Update: 2024-09-10): Electromagnetic Fault Injection in LOGO! V8.3 BM Devices Results in Broken LOGO! V8.3 Product CA
Published
Sept. 10, 2024, 2 a.m.
Summary
LOGO! V8.3 BM (incl. SIPLUS variants) devices contain a vulnerability that could allow an electromagnetic fault injection. This could allow an attacker to dump and debug the firmware, including the manipulation of memory. Further actions could allow to inject public keys of custom created key pairs which are then signed ...
Title
SSA-999588 V1.5 (Last Update: 2024-09-10): Multiple Vulnerabilities in User Management Component (UMC) Before V2.11.2
Published
Sept. 10, 2024, 2 a.m.
Summary
Siemens User Management Component (UMC) before V2.11.2 is affected by multiple vulnerabilities where the most severe could lead to a restart of the UMC server. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes ...
Title
SSA-921449 V1.1 (Last Update: 2024-09-10): Plaintext Storage of a Password Vulnerability in LOGO! V8.3 BM Devices
Published
Sept. 10, 2024, 2 a.m.
Summary
LOGO! V8.3 BM (incl. SIPLUS variants) devices contain a plaintext storage of a password vulnerability. This could allow an attacker with phyiscal access to an affected device to extract user-set passwords from an embedded storage IC. Siemens has released new hardware versions with the LOGO! V8.4 BM and the SIPLUS ...
Title
SSA-883918 V1.1 (Last Update: 2024-09-10): Information Disclosure Vulnerability in SIMATIC WinCC
Published
Sept. 10, 2024, 2 a.m.
Summary
Multiple versions of SIMATIC WinCC and SIMATIC PCS 7 do not properly handle certain requests to their web application (WinCC WebNavigator, PCS 7 Web Server, and PCS 7 Web Diagnostics Server), which may lead to the leak of privileged information. This could allow an unauthenticated remote attacker to retrieve information ...
Title
SSA-832273 V1.5 (Last Update: 2024-09-10): Multiple Vulnerabilities in Fortigate NGFW Before V7.4.3 on RUGGEDCOM APE1808 Devices
Published
Sept. 10, 2024, 2 a.m.
Summary
Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products. Siemens has released a new version of Fortigate NGFW for RUGGEDCOM APE1808 and recommends to update to the latest version. Siemens recommends to consult and implement the workarounds provided in Fortinet’s upstream security notifications.
Title
SSA-792319 V1.1 (Last Update: 2024-09-10): Missing Read Out Protection in SENTRON 7KM PAC3x20 Devices
Published
Sept. 10, 2024, 2 a.m.
Summary
The read out protection of the internal flash of affected devices was not properly set at the end of the manufacturing process. An attacker with physical access to the device could read out the data. Siemens has released new versions for the affected products and recommends to update to the ...
Title
SSA-773256 V1.0: Impact of Socket.IO CVE-2024-38355 on Siemens Industrial Products
Published
Sept. 10, 2024, 2 a.m.
Summary
A Socket.IO vulnerability affects multiple Siemens industrial products. This vulnerability consists of a specially crafted Socket.IO packet that triggers an uncaught exception on the Socket.IO server killing the Node.js process allowing a remote attacker to cause Denial-of-Service condition in the affected products. Siemens has released new versions for several affected ...
Title
SSA-765405 V1.0: Multiple Vulnerabilities in SIMATIC RFID Readers
Published
Sept. 10, 2024, 2 a.m.
Summary
SIMATIC RFID Readers contain multiple vulnerabilities that could allow an attacker to cause Denial-of-Service, exploit hidden functionality and information exposure. Siemens has released new versions for the affected products and recommends to update to the latest versions.
Title
SSA-969738 V1.0: Denial of Service Vulnerability in SIMATIC S7-200 SMART Devices
Published
Sept. 10, 2024, 2 a.m.
Summary
A vulnerability in SIMATIC S7-200 SMART devices could allow an attacker to cause a denial of service condition if a specially crafted TCP packet is sent to the device. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.
Title
SSA-691715 V1.6 (Last Update: 2024-09-10): Vulnerability in OPC Foundation Local Discovery Server Affecting Siemens Products
Published
Sept. 10, 2024, 2 a.m.
Summary
A vulnerability was identified in OPC Foundation Local Discovery Server which also affects Siemens products that could allow an attacker to escalate privileges under certain circumstances. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where ...
Title
SSA-698820 V1.2 (Last Update: 2024-09-10): Multiple Vulnerabilities in Fortigate NGFW on RUGGEDCOM APE1808 Devices
Published
Sept. 10, 2024, 2 a.m.
Summary
Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available. Siemens recommends to consult and implement the workarounds provided in Fortinet’s upstream security notifications.

Last Updates

BOSCH PSIRT
02.10.2024
SIEMENS CERT
12.09.2024
US CERT
19.09.2024
US CERT (ICS)
03.10.2024

By Source

Archive

2024
2023
2022
2021
2020
2019
2018
2017

Feeds