This medical advisory includes mitigations for a cross-site scripting vulnerability reported in Philips’ Tasy EMR, a clinical and administrative workflow-based information system.
This advisory includes mitigations for uncontrolled resource consumption and stack-based buffer overflow vulnerabilities reported in Rockwell Automation’s CompactLogix 5370 controllers.
This medical advisory includes mitigations for uncontrolled resource consumption and improper access control vulnerabilities reported in Fujifilm’s FCR Capsula X and Carbon X Computed Radiography cassette readers.
This advisory includes mitigations for an open redirect vulnerability reported in Rockwell Automation’s MicroLogix 1400 and CompactLogix 5370 controllers.
This advisory includes mitigations for a use of hard-coded credentials vulnerability reported in WAGO's 750-88x and 750-87x programmable logic controllers.
This advisory includes mitigations for an uncontrolled resource consumption vulnerability reported in ABB, Phoenix Contact, Schneider Electric, Siemens, and WAGO programmable logic controllers.
This advisory includes mitigations for an uncontrolled resource consumption vulnerability reported in Siemens' SIMOCODE pro V EIP low-voltage motor management system.
This advisory includes mitigations for incorrect calculation of buffer size, out-of-bounds read, stack-based buffer overflow, and improper handling of insufficient permissions vulnerabilities in Siemens' SINEMA Remote Connect server application.
This advisory includes mitigations for double free, out-of-bounds read, and uncontrolled resource consumption vulnerabilities reported in Siemens' RUGGEDCOM ROX II.
This advisory includes mitigations for an out-of-bounds read vulnerability reported in Siemens' CP, SIAMTIC, SIMOCODE, SINAMICS, SITOP, and TIM products.
A vulnerability in OpenSSL affects several Siemens industrial products. Siemens has released updates for some affected products and is working on updates for others.
Multiple vulnerabilities affecting WPA/WPA2 implementations were identified by a researcher and publicly disclosed under the term "Key Reinstallation Attacks" (KRACK). These vulnerabilities could potentially allow an attacker within the radio range of the wireless network to decrypt, replay or inject forged network packets into the wireless communication. Several Siemens Industrial ...
The latest update for RUGGEDCOM ROX II fixes multiple vulnerabilities in third party component software. The most severe vulnerability could allow an attacker to run arbitrary code on the device. Siemens has released firmware updates for RUGGEDCOM ROX II and recommends that customers update to the new version.
The latest updates for SINEMA Remote Connect Client and Server fix multiple vulnerabilities. One of these vulnerabilities could allow an attacker to circumvent the authorization of the system for certain functionalities and to execute privileged functions. Siemens has released firmware updates for SINEMA Remote Connect Client and Server.
Versions of Spectrum Power™ 4, that use the customer specific project enhancement (PE) Web Office Portal (WOP) are affected by a possible OS Command Injection vulnerability. Siemens has released patches for the affected version and recommends to apply specific countermeasures until these patches can be applied.
Multiple vulnerabilities have been identified in the WibuKey Digital Rights Management (DRM) solution, which affect WinCC OA. Siemens recommends users to apply the updates to WibuKey Digital Rights Management (DRM) provided by WIBU SYSTEMS AG.
A vulnerability in the affected devices could allow an unauthorized attacker with network access to the webserver of an affected device to perform a denial-of-service attack. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates and recommends ...
SIMOCODE pro V EIP is affected by a vulnerability that could allow remote attackers to conduct a Denial-of-Service (DoS) attack by sending specially crafted packets to port 161/udp (SNMP). Siemens has released an update for SIMOCODE pro V EIP and recommends that customers update to the new version.
A vulnerability has been identified in the OPC UA server of several industrial products. The vulnerability could cause a Denial-of-Service condition on the service or the device. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates and ...
Security researchers published information on vulnerabilities known as Spectre-NG (Variants 3a and 4). These vulnerabilities affect many modern processors from different vendors to a varying degree. Several Industrial Products include affected processors and are affected by the vulnerabilities.
This advisory includes mitigations for an uncontrolled resource consumption vulnerability reported in Rockwell Automation's Stratix and ArmorStratix Ethernet switches.