• 1
  • 2 (current)
Tuesday, 09.02.2021
Title
SSA-455843 V1.4 (Last Update: 2021-02-09): WIBU Systems CodeMeter Runtime Vulnerabilities in Siemens and Siemens Energy Products
Published
Feb. 9, 2021, 1 a.m.
Summary
CISA and WIBU Systems disclosed six vulnerabilities in different versions of CodeMeter Runtime, a product provided by WIBU Systems and used in several Siemens and Siemens Energy products for license management. The vulnerabilities are described in the section “Vulnerability Classification” below and got assigned the CVE IDs CVE-2020-14509, CVE-2020-14513, CVE-2020-14515, ...
Title
SSA-534763 V1.3 (Last Update: 2021-02-09): Special Register Buffer Data Sampling (SRBDS) aka Crosstalk in Industrial Products
Published
Feb. 9, 2021, 1 a.m.
Summary
Security researchers published information on a vulnerability known as Crosstalk (INTEL-SA-00320). This vulnerability affects modern Intel processors to a varying degree. Several Siemens Industrial Products contain processors that are affected by the vulnerability. Siemens is preparing updates and recommends specific countermeasures until fixes are available.
Title
SSA-541017 V1.1 (Last Update: 2021-02-09): Embedded TCP/IP Stack Vulnerabilities (AMNESIA:33) in SIRIUS 3RW5 Modbus TCP and SENTRON PAC / 3VA Devices
Published
Feb. 9, 2021, 1 a.m.
Summary
Security researchers discovered and disclosed 33 vulnerabilities in several open-source TCP/IP stacks for embedded devices, also known as “AMNESIA:33” vulnerabilities. The Siemens products mentioned below are affected by one of these vulnerabilities (CVE-2020-13988). Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens ...
Title
SSA-686152 V1.0: Denial-of-Service Vulnerability in ARP Protocol of SCALANCE W780 and W740
Published
Feb. 9, 2021, 1 a.m.
Summary
A Denial-of-Service vulnerability was found affecting the ARP protocol on older firmware versions of the SCALANCE W780 and W740 (IEEE 802.11n) devices. Siemens recommends to update to the latest version.
Title
SSA-646841 V1.2 (Last Update: 2021-02-09): Recoverable Password from Configuration Storage in SCALANCE X Switches
Published
Feb. 9, 2021, 1 a.m.
Summary
A vulnerability exists in several SCALANCE X switches that could allow external entities to reconstruct passwords for users of the affected devices if an attacker is able to obtain a backup of the device configuration. Siemens has released updates for several affected products and recommends to update to the latest ...
Title
SSA-663999 V1.0: Multiple File Parsing Vulnerabilities in JT2Go and Teamcenter Visualization before V13.1.0.1
Published
Feb. 9, 2021, 1 a.m.
Summary
Siemens has released version V13.1.0.1 for JT2Go and Teamcenter Visualization to fix multiple vulnerabilities that could be triggered when the products read files in different file formats (PAR, BMP, TIFF, CGM, TGA, PCT, HPG, PLT, RAS, ASM, DGN, DXF, DWG). If a user is tricked to opening of a malicious ...
Title
SSA-841348 V1.5 (Last Update: 2021-02-09): Multiple Vulnerabilities in the UMC Stack
Published
Feb. 9, 2021, 1 a.m.
Summary
The latest update for the below listed products fixes two security vulnerabilities that could allow an attacker to cause a partial Denial-of-Service on the UMC component of the affected devices under certain circumstances, and one vulnerability that could allow an attacker to locally escalate privileges from a user with administrative ...
Title
SSA-886514 V1.1 (Last Update: 2021-02-09): Persistent XSS Vulnerabilities in the Web Interface of Climatix POL908 and POL909 Modules
Published
Feb. 9, 2021, 1 a.m.
Summary
The Climatix BACnet/IP (POL908) and AWM (POL909) modules contain two persistent cross-site scripting (XSS) vulnerabilities in the web interface that could allow a remote attacker to execute arbitrary JavaScript code in the context of other users’ web sessions. Siemens has released an update for Climatix POL909 and recommends to update ...
Title
SSA-951513 V1.1 (Last Update: 2021-02-09): Clickjacking Vulnerability in SCALANCE X-300, X-200IRT, and X-200 Switch Families
Published
Feb. 9, 2021, 1 a.m.
Summary
Several SCALANCE X switches contain a vulnerability that could allow an attacker to perform administrative actions if the victim is tricked into clicking on a website controlled by the attacker. The attack only works if the victim has an authenticated session on the administrative interface of the switch. Siemens has ...
Title
SSA-978220 V1.3 (Last Update: 2021-02-09): Denial-of-Service Vulnerability over SNMP in Multiple Industrial Products
Published
Feb. 9, 2021, 1 a.m.
Summary
Several industrial products are affected by a vulnerability that could allow remote attackers to conduct a Denial-of-Service (DoS) attack by sending specially crafted packets to port 161/udp (SNMP). Siemens has released updates for several affected products and recommends to update to the new versions. Siemens is preparing further updates and ...
Title
SSA-536315 V1.0: Privilege escalation vulnerability in DIGSI 4
Published
Feb. 9, 2021, 1 a.m.
Summary
A vertical privilege escalation vulnerability exists in DIGSI 4. Siemens has released an update for DIGSI 4 and recommends to update to the latest version.
Title
SSA-428051 V1.0: Privilege Escalation Vulnerability in TIA Administrator
Published
Feb. 9, 2021, 1 a.m.
Summary
The latest update for TIA Administrator, installed together with TIA Portal and PCS neo, fixes a privilege escalation vulnerability that could allow local users to escalate privileges and execute code as local SYSTEM user. Siemens has released an update for TIA Portal and recommends that customers update to the latest ...
Title
SSA-379803 V1.0: Vulnerabilities in RUGGEDCOM ROX II
Published
Feb. 9, 2021, 1 a.m.
Summary
The latest update for ROX II contains multiple fixes for IPsec related vulnerabilities in Libreswan and NSS. Siemens has released updates for the affected products and recommends to update to the latest versions.
Title
SSA-362164 V1.0: Predictable Initial Sequence Numbers in Mentor Nucleus TCP stack
Published
Feb. 9, 2021, 1 a.m.
Summary
Some versions of Mentor Nucleus ReadyStart and Nucleus NET use Initial Sequence Numbers for TCP- Sessions that are predictable. Siemens has released updates for the affected products and recommends to update to the latest version(s).
Title
SSA-156833 V1.0: Zip-Slip Directory Traversal Vulnerability in SINEMA Server and SINEC NMS
Published
Feb. 9, 2021, 1 a.m.
Summary
There exists a directory traversal vulnerability which allows arbitrary file upload to an affected system. This type of vulnerability is also known as ‘Zip-Slip’. An authenticated attacker could exploit this vulnerability to gain arbitrary code execution by uploading a new or modifying an existing file to an affected system. Siemens ...
Title
SSA-622830 V1.1 (Last Update: 2021-02-09): Multiple File Parsing Vulnerabilities in JT2Go and Teamcenter Visualization before V13.1.0
Published
Feb. 9, 2021, 1 a.m.
Summary
Siemens has released version V13.1.0 for JT2Go and Teamcenter Visualization to fix multiple vulnerabilities that could be triggered when the products read files in different file formats (JT, XML, CG4, CGM, PDF, RGB, SGI, TGA, PAR, ASM, PCX). If a user is tricked to opening of a malicious file with ...
Title
SSA-794542 V1.0: Insecure Folder Permissions in SIMARIS configuration
Published
Feb. 9, 2021, 1 a.m.
Summary
The installation of SIMARIS configuration causes insecure folder permissions that could allow vertical privilege escalation. Siemens is preparing updates and recommends specific countermeasures until fixes are available.
  • 1
  • 2 (current)

Last Updates

BOSCH PSIRT
31.10.2024
SIEMENS CERT
26.11.2024
US CERT
08.11.2024
US CERT (ICS)
03.12.2024

By Source

Archive

2024
2023
2022
2021
2020
2019
2018
2017

Feeds