• 1
  • 2
  • 3 (current)
  • 4
Tuesday, 14.06.2022
Title
SSA-789162 V1.1 (Last Update: 2022-06-14): Vulnerabilities in Teamcenter
Published
June 14, 2022, 2 a.m.
Summary
Teamcenter is affected by XML External Entity Injection (XXE, CVE-2022-29801) and a stack based buffer overflow vulnerability (CVE-2022-24290). XXE impacts only Teamcenter versions before V13.1. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends specific countermeasures ...
Title
SSA-780073 V2.2 (Last Update: 2022-06-14): Denial of Service Vulnerability in PROFINET Devices via DCE-RPC Packets
Published
June 14, 2022, 2 a.m.
Summary
Products that include the Siemens PROFINET-IO (PNIO) stack in versions prior V06.00 are potentially affected by a denial of service vulnerability when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. Siemens has released updates for several affected products and recommends to update to the new versions. Siemens ...
Title
SSA-772220 V2.0 (Last Update: 2022-06-14): OpenSSL Vulnerabilities in Industrial Products
Published
June 14, 2022, 2 a.m.
Summary
OpenSSL has published a security advisory [0] about a vulnerability in OpenSSL versions 1.1.1 < 1.1.1k, that allows an unauthenticated attacker to cause a Denial-of-Service (DoS) if a maliciously crafted renegotiation message is sent . Siemens has released updates for several affected products and recommends to update to the latest ...
Title
SSA-764417 V1.3 (Last Update: 2022-06-14): Weak Encryption Vulnerability in RUGGEDCOM ROS Devices
Published
June 14, 2022, 2 a.m.
Summary
The SSH server on RUGGEDCOM ROS devices is configured to offer weak ciphers by default. This could allow an unauthorized attacker in a man-in-the-middle position to read and modify any data passed over the connection between legitimate clients and the affected device. Siemens recommends specific countermeasures for products where updates ...
Title
SSA-740594 V1.0: Privilege Escalation Vulnerability in Mendix SAML Module
Published
June 14, 2022, 2 a.m.
Summary
The latest updates of Mendix the SAML module fixes two vulnerabilities. One is an XML External Entity (XXE) attack that could allow an attacker to potentially disclose confidential data under certain circumstances the other is an Cross Site Scripting (XSS) attack allowing to execute malicious code by tricking users into ...
Title
SSA-732250 V1.1 (Last Update: 2022-06-14): Libcurl Vulnerabilities in Industrial Devices
Published
June 14, 2022, 2 a.m.
Summary
Vulnerabilities in third-party component cURL could allow an attacker to interfere with the affected products in various ways. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends countermeasures for products where updates are not, or not ...
Title
SSA-712929 V1.0: Denial of Service Vulnerability in OpenSSL (CVE-2022-0778) Affecting Industrial Products
Published
June 14, 2022, 2 a.m.
Summary
A vulnerability in the openSSL component (CVE-2022-0778, [0]) could allow an attacker to create a denial of service condition by providing specially crafted elliptic curve certificates to products that use a vulnerable version of openSSL. Siemens has released updates for several affected products and recommends to update to the latest ...
Title
SSA-685781 V1.0: Multiple Vulnerabilities in Apache HTTP Server Affecting Siemens Products
Published
June 14, 2022, 2 a.m.
Summary
Multiple vulnerabilities were identified in the Apache HTTP Server software. These include NULL Pointer Dereferencing, Out-of-bounds Write and Server-Side Request Forgery related vulnerabilities. Siemens has released an update for the SINEMA Remote Connect Server and recommends to update to the latest version. Siemens is preparing further updates and recommends specific ...
Title
SSA-679335 V1.1 (Last Update: 2022-06-14): Multiple Vulnerabilities in Embedded FTP Server of SIMATIC CP Modules
Published
June 14, 2022, 2 a.m.
Summary
SIMATIC CP 1543-1 and CP 1545-1 devices are affected by multiple vulnerabilities in ProFTPD, a third party component, that could allow a remote attacker to access sensitive information and execute arbitrary code. Siemens has released updates for the affected products and recommends to update to the latest versions.
Title
SSA-662649 V1.1 (Last Update: 2022-06-14): Denial of Service Vulnerability in Desigo DXR and PXC Controllers
Published
June 14, 2022, 2 a.m.
Summary
A vulnerability in Desigo DXR and PXC controllers has been identified that could allow an attacker to disable and reset a device to factory state using a denial of service attack. Siemens has released updates for the affected products and recommends to update to the latest versions.
Title
SSA-661247 V2.9 (Last Update: 2022-06-14): Apache Log4j Vulnerabilities (Log4Shell, CVE-2021-44228, CVE-2021-45046) - Impact to Siemens Products
Published
June 14, 2022, 2 a.m.
Summary
On 2021-12-09, a vulnerability in Apache Log4j (a logging tool used in many Java-based applications) was disclosed, that could allow remote unauthenticated attackers to execute code on vulnerable systems. The vulnerability is tracked as CVE-2021-44228 and is also known as “Log4Shell”. On 2021-12-14 an additional denial of service vulnerability (CVE-2021-45046) ...
Title
SSA-631336 V1.0: Multiple Web Server Vulnerabilities in SICAM GridEdge Software
Published
June 14, 2022, 2 a.m.
Summary
Multiple vulnerabilities were identified in the webserver of the SICAM GridEdge application which includes missing authentication for critical API functions, absent cross-origin resource sharing restrictions and access to credentials. Siemens has released updates for the affected products and recommends to update to the latest versions.
Title
SSA-629512 V1.5 (Last Update: 2022-06-14): Local Privilege Escalation Vulnerability in TIA Portal
Published
June 14, 2022, 2 a.m.
Summary
The latest updates for TIA Portal fix a vulnerability that could allow a local attacker to execute arbitrary code with SYSTEM privileges. Update: The previously provided fixes only correctly set the permissions on English Windows versions. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, ...
Title
SSA-626968 V1.1 (Last Update: 2022-06-14): Multiple Webserver Vulnerabilities in Desigo PXC and DXR Devices
Published
June 14, 2022, 2 a.m.
Summary
Desigo PXC3, PXC4, PXC5 and DXR2 devices contain multiple vulnerabilities in the webserver application that could allow an attacker to potentially intercept unencrypted transmission of sensitive information, cause a denial of service condition, or perform remote code execution. Siemens has released updates for the affected products and recommends to update ...
Title
SSA-593272 V1.7 (Last Update: 2022-06-14): SegmentSmack in Interniche IP-Stack based Industrial Devices
Published
June 14, 2022, 2 a.m.
Summary
A vulnerability exists in affected products that could allow remote attackers to affect the availability of the devices under certain conditions. The underlying TCP stack can be forced to make very computation expensive calls for every incoming packet which can lead to a Denial-of-Service. Siemens has released updates for several ...
Title
SSA-592007 V1.7 (Last Update: 2022-06-14): Denial-of-Service Vulnerability in Industrial Products
Published
June 14, 2022, 2 a.m.
Summary
Several industrial controllers are affected by a security vulnerability that could allow an attacker to cause a Denial-of-Service condition via PROFINET DCP network packets under certain circumstances. Precondition for this scenario is a direct OSI Layer 2 access to the affected products. PROFIBUS interfaces are not affected. Siemens has released ...
Title
SSA-549234 V1.2 (Last Update: 2022-06-14): Denial-of-Service Vulnerability in SIMATIC NET CP Modules
Published
June 14, 2022, 2 a.m.
Summary
A denial of service vulnerability was identified in different types of Communication Processors. An attacker could exploit this vulnerability causing the device to become un-operational until the device is restarted. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available.
Title
SSA-539476 V1.2 (Last Update: 2022-06-14): Siemens SIMATIC NET CP, SINEMA and SCALANCE Products Affected by Vulnerabilities in Third-Party Component strongSwan
Published
June 14, 2022, 2 a.m.
Summary
Vulnerabilities in the third-party component strongSwan could allow an attacker to cause a denial of service (DoS) condition in affected devices by exploiting integer overflow bugs. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends countermeasures ...
Title
SSA-535997 V1.1 (Last Update: 2022-06-14): Cleartext Storage of Sensitive Information in Multiple SIMATIC Products
Published
June 14, 2022, 2 a.m.
Summary
A cleartext vulnerability was found in the SIMATIC communication processors CP 1543-1 and CP 1545-1 that could allow an attacker to read sensitive information. Siemens has released updates for the affected products and recommends to update to the latest versions.
Title
SSA-484086 V1.0: Multiple Vulnerabilities in SINEMA Remote Connect Server before V3.1
Published
June 14, 2022, 2 a.m.
Summary
SINEMA Remote Connect Server is affected by multiple vulnerabilities, including A cross-site scripting vulnerability in an error message pop up window (CVE-2022-29034) Several authentication bypass, privilege escalation and integrity check vulnerabilities (CVE-2022-32251 through -32261) A command injection vulnerability in the file upload service (CVE-2022-32262) A chosen-plaintext attack against HTTP over ...
Title
SSA-480230 V2.3 (Last Update: 2022-06-14): Denial of service in Webserver of Industrial Products
Published
June 14, 2022, 2 a.m.
Summary
A vulnerability in the affected devices could allow an unauthorized attacker with network access to the webserver of an affected device to perform a denial of service attack. Siemens has released updates for several affected products and recommends to update to the new versions. Siemens is preparing further updates and ...
Title
SSA-462066 V3.0 (Last Update: 2022-06-14): Vulnerability known as TCP SACK PANIC in Industrial Products
Published
June 14, 2022, 2 a.m.
Summary
Multiple industrial products are affected by a vulnerability in the kernel known as TCP SACK PANIC. The vulnerability could allow a remote attacker to cause a denial of service condition. Siemens has released updates for several affected products and recommends to update to the new versions. Siemens is preparing further ...
Title
SSA-446448 V1.1 (Last Update: 2022-06-14): Denial of Service Vulnerability in PROFINET Stack Integrated on Interniche Stack
Published
June 14, 2022, 2 a.m.
Summary
The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, contains a vulnerability that could allow an attacker to cause a denial of service condition on affected industrial products. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further ...
Title
SSA-443566 V1.2 (Last Update: 2022-06-14): Authentication Bypass in SCALANCE X Switches Families
Published
June 14, 2022, 2 a.m.
Summary
Several SCALANCE X switches are affected by an Authentication Bypass vulnerability. The vulnerability allows an unauthenticated attacker to violate access-control rules. The vulnerability can be exploited by sending a GET request to a specific uniform resource locator on the web configuration interface of the device. The security vulnerability could be ...
Title
SSB-439005 V4.4 (Last Update: 2022-06-14): Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP
Published
June 14, 2022, 2 a.m.
Summary
  • 1
  • 2
  • 3 (current)
  • 4

Last Updates

BOSCH PSIRT
06.12.2024
SIEMENS CERT
16.12.2024
US CERT
08.11.2024
US CERT (ICS)
19.12.2024

By Source

Archive

2024
2023
2022
2021
2020
2019
2018
2017

Feeds