• 1
  • 2 (current)
  • 3
Tuesday, 14.05.2024
Title
SSA-446448 V2.0 (Last Update: 2024-05-14): Denial of Service Vulnerability in PROFINET Stack Integrated on Interniche Stack
Published
May 14, 2024, 2 a.m.
Summary
The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, contains a vulnerability that could allow an attacker to cause a denial of service condition on affected industrial products. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing ...
Title
SSA-398330 V1.5 (Last Update: 2024-05-14): Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP V3.1
Published
May 14, 2024, 2 a.m.
Summary
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version V3.1 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not ...
Title
SSA-382651 V1.1 (Last Update: 2024-05-14): File Parsing Vulnerability in Solid Edge
Published
May 14, 2024, 2 a.m.
Summary
Solid Edge is affected by an out of bounds read vulnerability that could be triggered when the application reads files that contains XT parts. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the vulnerability to perform remote code execution in ...
Title
SSA-322980 V1.4 (Last Update: 2024-05-14): Denial of Service Vulnerability in SIPROTEC 5 Devices
Published
May 14, 2024, 2 a.m.
Summary
SIPROTEC 5 devices contain a null pointer dereference vulnerability in the web service. This could allow an attacker to send unauthenticated maliciously crafted http request that could cause denial of service condition of the device. Siemens has released new versions for several affected products and recommends to update to the ...
Title
SSA-292063 V1.1 (Last Update: 2024-05-14): Multiple Vulnerabilities in Nozomi Guardian/CMC before 22.6.3 and 23.1.0 on RUGGEDCOM APE1808 devices
Published
May 14, 2024, 2 a.m.
Summary
Nozomi Networks has published information on vulnerabilities in Nozomi Guardian/CMC before V22.6.3 and 23.1.0. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available. Customers are advised to consult and ...
Title
SSA-292022 V1.0: Vulnerability in Nozomi Guardian/CMC before 23.4.1 on RUGGEDCOM APE1808 devices
Published
May 14, 2024, 2 a.m.
Summary
Nozomi Networks has published information on vulnerabilities in Nozomi Guardian/CMC before 23.4.1. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens has released a new version for RUGGEDCOM APE1808 and recommends to update to the latest version. Customers are advised to consult and implement the workarounds ...
Title
SSA-265688 V1.1 (Last Update: 2024-05-14): Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.1
Published
May 14, 2024, 2 a.m.
Summary
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.1. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.
Title
SSA-258494 V1.0: Stack Overflow Vulnerability in Simcenter Nastran before 2406.90
Published
May 14, 2024, 2 a.m.
Summary
Simcenter Nastran is affected by a stack overflow vulnerability that could be triggered when an application binary reads arbitrary string as a file argument. If a user is tricked to run one of the impacted application binary with a malicious string, an attacker could leverage the vulnerability to perform remote ...
Title
SSA-240541 V1.3 (Last Update: 2024-05-14): WIBU Systems CodeMeter Heap Buffer Overflow Vulnerability in Industrial Products
Published
May 14, 2024, 2 a.m.
Summary
WIBU Systems published information about a heap buffer overflow vulnerability and associated fix releases of CodeMeter Runtime, a product provided by WIBU Systems and used in several Siemens industrial products for license management. The vulnerability is described in the section ‘Vulnerability Classification’ below and got assigned the CVE ID CVE-2023-3935. ...
Title
SSA-225840 V1.1 (Last Update: 2024-05-14): Vulnerabilities in the Network Communication Stack in Sinteso EN and Cerberus PRO EN Fire Protection Systems
Published
May 14, 2024, 2 a.m.
Summary
Several products used in Sinteso EN and Cerberus PRO EN Fire Protection Systems contain buffer overflow vulnerabilities in the network communication stack. Successful exploitation of the vulnerabilities could allow an unauthenticated attacker, who gained access to the fire protection system network, to execute arbitrary code on the affected products (CVE-2024-22039) ...
Title
SSA-148641 V1.2 (Last Update: 2024-05-14): XPath Constraint Vulnerability in Mendix Runtime
Published
May 14, 2024, 2 a.m.
Summary
A XPath Constraint vulnerability in the Mendix Runtime was discovered, that can affect the running applications. The vulnerability could allow a malicious user to deduce contents of inaccessible attributes and modify sensitive data. Siemens has released new versions for the affected products and recommends to update to the latest versions.
Title
SSA-093430 V1.0: Multiple Vulnerabilities in SIMATIC RTLS Locating Manager before V3.0
Published
May 14, 2024, 2 a.m.
Summary
Siemens has released a new version for SIMATIC RTLS Locating Manager and recommends to update to the latest version.
Title
SSA-046364 V1.0: X_T File Parsing Vulnerabilities in Parasolid
Published
May 14, 2024, 2 a.m.
Summary
Parasolid is affected by out of bounds read and null pointer dereference vulnerabilities that could be triggered when the application reads files in X_T format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the out of bounds read vulnerabilities to ...
Title
SSA-273900 V1.0: Multiple Vulnerabilities in SIMATIC CN 4100 before V3.0
Published
May 14, 2024, 2 a.m.
Summary
SIMATIC CN 4100 is vulnerable to use of hard coded credentials including root user and contains an unrestricted USB port that could be misused for insecure boot. Siemens has released a new version for SIMATIC CN 4100 and recommends to update to the latest version.
Title
SSA-999588 V1.3 (Last Update: 2024-05-14): Multiple Vulnerabilities in User Management Component (UMC) before V2.11.2
Published
May 14, 2024, 2 a.m.
Summary
Siemens User Management Component (UMC) before V2.11.2 is affected by multiple vulnerabilities where the most severe could lead to a restart of the UMC server. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends ...
Title
SSA-976324 V1.0: Multiple IGS File Parsing Vulnerabilities in PS/IGES Parasolid Translator Component before V27.1.215
Published
May 14, 2024, 2 a.m.
Summary
PS/IGES Parasolid Translator Component contains multiple file parsing vulnerabilities that could be triggered when the application reads files in IGS file formats. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary ...
Title
SSA-968170 V1.3 (Last Update: 2024-05-14): Remote Code Execution Vulnerability in SIMATIC STEP 7 V5.x and Derived Products
Published
May 14, 2024, 2 a.m.
Summary
SIMATIC STEP 7 and PCS 7 contain a database management system that could allow remote users to use embedded functions of the database (local or in a network share) that have impact on the server. An attacker with network access to the server network could leverage these embedded functions to ...
Title
SSA-962515 V1.0: Out of Bounds Read Vulnerability in Industrial Products
Published
May 14, 2024, 2 a.m.
Summary
Several industrial products contain an out of bounds read vulnerability that could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel, leading to denial of service condition. Siemens has released new versions for several affected products and recommends to update to the ...
Title
SSA-953710 V1.0: Vulnerabilities in the Network Communication Stack in Desigo Fire Safety UL and Cerberus PRO UL Fire Protection Systems
Published
May 14, 2024, 2 a.m.
Summary
Several products used in Desigo Fire Safety UL and Cerberus PRO UL Fire Protection Systems contain buffer overflow vulnerabilities in the network communication stack. Successful exploitation of the vulnerabilities could allow an unauthenticated attacker, who gained access to the fire protection system network, to execute arbitrary code on the affected ...
Title
SSA-935500 V1.1 (Last Update: 2024-05-14): Denial of Service Vulnerability in FTP Server of Nucleus RTOS based APOGEE, TALON and Desigo PXC/PXM Products
Published
May 14, 2024, 2 a.m.
Summary
A denial of service vulnerability has been identified in the Nucleus RTOS (real-time operating system) and reported in the Siemens Security Advisory SSA-313313: https://cert-portal.siemens.com/productcert/html/ssa-313313.html. The products listed below use affected versions of the Nucleus software and inherently contain the vulnerability. Siemens has released new versions for several affected products and ...
Title
SSA-925850 V1.0: Improper Access Control in Polarion ALM
Published
May 14, 2024, 2 a.m.
Summary
The Apache Lucene based query engine in Polarion ALM lacks proper access controls. This could allow an authenticated user to query items beyond the user’s allowed projects. Siemens has released a new version for Polarion ALM and recommends to update to the latest version.
Title
SSA-923361 V1.0: MODEL File Parsing Vulnerability in Tecnomatix Plant Simulation before V2302.0011
Published
May 14, 2024, 2 a.m.
Summary
Tecnomatix Plant Simulation contains an out of bounds write vulnerability that could be triggered when the application reads MODEL files. If a user is tricked to open a malicious file using the affected application, this could lead to a crash, and potentially also to arbitrary code execution on the target ...
Title
SSA-916916 V1.0: Security Vulnerabilities Fixed in RUGGEDCOM CROSSBOW V5.5
Published
May 14, 2024, 2 a.m.
Summary
The RUGGEDCOM CROSSBOW server application before V5.5 contains multiple vulnerabilities that could allow an attacker to execute arbitrary database queries via SQL injection attacks, or upload of arbitrary files to the application’s file system. The majority of the reported vulnerabilities might have a high impact in the availability of the ...
Title
SSA-871717 V1.2 (Last Update: 2024-05-14): Multiple Vulnerabilities in Polarion ALM
Published
May 14, 2024, 2 a.m.
Summary
Polarion ALM is affected by incorrect default path permissions in installation path, and improper authentication in the REST API endpoints of DOORS connector. An attacker could exploit the vulnerabilities for unauthenticated access, or privilege escalation. Siemens has released a new version for Polarion ALM and recommends to update to the ...
Title
SSA-871704 V1.0: Multiple Vulnerabilities in SICAM Products
Published
May 14, 2024, 2 a.m.
Summary
Multiple SICAM products are affected by vulnerabilities that could lead to privilege escalation, remote code execution or information loss namely: SICAM A8000 device firmwares CPC80 for CP-8000/CP-8021/CP-8022 CPCI85 and OPUPI0 for CP-8031/CP-8050 SICAM EGS firmware CPCI85 and OPUPI0 SICAM 8 Software Solution SICORE Siemens has released new versions for the ...
  • 1
  • 2 (current)
  • 3

Last Updates

BOSCH PSIRT
21.08.2024
SIEMENS CERT
12.09.2024
US CERT
04.09.2024
US CERT (ICS)
19.09.2024

By Source

Archive

2024
2023
2022
2021
2020
2019
2018
2017

Feeds