• 1
  • 2
  • 3 (current)
Tuesday, 09.07.2024
Title
SSA-753746 V1.3 (Last Update: 2024-07-09): Denial of Service Vulnerabilities in SIMATIC WinCC Affecting Other SIMATIC Software Products
Published
July 9, 2024, 2 a.m.
Summary
Two null point dereference vulnerabilities affect multiple SIMATIC software products. These could allow an attacker to cause a persistent denial of service condition in the RPC Server of these products. Siemens has released new versions for the affected products and recommends to update to the latest versions.
Title
SSA-750499 V1.0: Weak Encryption Vulnerability in SIPROTEC 5 Devices
Published
July 9, 2024, 2 a.m.
Summary
The SIPROTEC 5 devices are supporting weak encryption. This could allow an unauthorized attacker in a man-in-the-middle position to read any data passed over the connection between legitimate clients and the affected device. Siemens has released new versions for several affected products and recommends to update to the latest versions. ...
Title
SSA-750274 V1.1 (Last Update: 2024-07-09): Impact of CVE-2024-3400 on RUGGEDCOM APE1808 devices configured with Palo Alto Networks Virtual NGFW
Published
July 9, 2024, 2 a.m.
Summary
Palo Alto Networks has published [1] information on CVE-2024-3400 in PAN-OS. This advisory addresses Siemens Industrial products affected by this vulnerability. Siemens has released a new version of Palo Alto Networks Virtual NGFW for RUGGEDCOM APE1808 and recommends to update to the latest version. Customers are advised to consult and ...
Title
SSA-730482 V1.1 (Last Update: 2024-07-09): Denial of Service Vulnerability in SIMATIC WinCC
Published
July 9, 2024, 2 a.m.
Summary
A vulnerability in the login dialog box of SIMATIC WinCC could allow a local attacker to cause a denial of service condition in the runtime of the SCADA system. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further ...
Title
SSA-723487 V1.0: RADIUS Protocol Susceptible to Forgery Attacks (CVE-2024-3596) - Impact to SCALANCE, RUGGEDCOM and Related Products
Published
July 9, 2024, 2 a.m.
Summary
This advisory documents the impact of CVE-2024-3596 (also dubbed “Blastradius”), a vulnerability in the RADIUS protocol, to SCALANCE, RUGGEDCOM and related products. The vulnerability could allow on-path attackers, located between a Network Access Server (the RADIUS client, e.g., SCALANCE or RUGGEDCOM devices) and a RADIUS server (e.g., SINEC INS), to ...
Title
SSA-722010 V1.0: Datalogics File Parsing Vulnerability in Teamcenter Visualization and JT2Go
Published
July 9, 2024, 2 a.m.
Summary
Siemens Teamcenter Visualization and JT2Go are affected by an out of bounds read vulnerability in the APDFL library from Datalogics. If a user is tricked to open a malicious PDF file with the affected products, this could lead the application to crash or potentially lead to arbitrary code execution. Siemens ...
Title
SSA-712929 V2.8 (Last Update: 2024-07-09): Denial of Service Vulnerability in OpenSSL (CVE-2022-0778) Affecting Industrial Products
Published
July 9, 2024, 2 a.m.
Summary
A vulnerability in the openSSL component (CVE-2022-0778, [0]) could allow an attacker to create a denial of service condition by providing specially crafted elliptic curve certificates to products that use a vulnerable version of openSSL. Siemens has released new versions for several affected products and recommends to update to the ...
Title
SSA-711309 V2.0 (Last Update: 2024-07-09): Denial of Service Vulnerability in the OPC UA Implementations of SIMATIC Products
Published
July 9, 2024, 2 a.m.
Summary
The OPC UA implementations (ANSI C and C++) as used in several SIMATIC products contain a denial of service vulnerability that could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate. Siemens has released new versions for several affected products and ...
Title
SSA-698820 V1.0: Multiple Vulnerabilities in Fortigate NGFW on RUGGEDCOM APE1808 devices
Published
July 9, 2024, 2 a.m.
Summary
Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available. Siemens recommends to consult and implement the workarounds provided in Fortinet’s upstream security notifications.
Title
SSA-686975 V1.4 (Last Update: 2024-07-09): IPU 2022.3 Vulnerabilities in Siemens Industrial Products using Intel CPUs
Published
July 9, 2024, 2 a.m.
Summary
Intel has published information on vulnerabilities in Intel products in November 2022. This advisory lists the related Siemens Industrial products affected by these vulnerabilities that can be patched by applying the corresponding BIOS update (“2022.3 IPU – BIOS Advisory” Intel-SA-00688). Siemens is preparing updates and recommends specific countermeasures for products ...
Title
SSA-593272 V2.2 (Last Update: 2024-07-09): SegmentSmack in Interniche IP-Stack based Industrial Devices
Published
July 9, 2024, 2 a.m.
Summary
A vulnerability exists in affected products that could allow remote attackers to affect the availability of the devices under certain conditions. The underlying TCP stack can be forced to make very computation expensive calls for every incoming packet which can lead to a Denial-of-Service. Siemens has released new versions for ...
Monday, 08.07.2024
Title
People’s Republic of China (PRC) Ministry of State Security APT40 Tradecraft in Action
Published
July 8, 2024, 3:52 p.m.
Summary
Overview Background This advisory, authored by the Australian Signals Directorate’s Australian Cyber Security Centre (ASD’s ACSC), the United States Cybersecurity and Infrastructure Security Agency (CISA), the United States National Security Agency (NSA), the United States Federal Bureau of Investigation (FBI), the United Kingdom National Cyber Security Centre (NCSC-UK), the Canadian ...
Tuesday, 02.07.2024
Title
Johnson Controls Kantech Door Controllers
Published
July 2, 2024, 2 p.m.
Summary
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 3.1 ATTENTION: Exploitable via adjacent network Vendor: Johnson Controls, Inc. Equipment: Kantech KT1, KT2, KT400 Door Controllers Vulnerability: Exposure of Sensitive Information to an Unauthorized Actor 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to gain access to sensitive ...