AutomationDirect DirectLogic H2-DM1E
Published
Sept. 12, 2024, 2 p.m.
Summary
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable from an adjacent network/low attack complexity Vendor: AutomationDirect Equipment: DirectLogic H2-DM1E Vulnerabilities: Session Fixation, Authentication Bypass by Capture-replay 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to inject traffic into an ongoing authenticated session or authenticate ...
Title
SSA-097435 V1.1 (Last Update: 2024-09-12): Usernames Disclosure Vulnerability in Mendix Runtime
Published
Sept. 12, 2024, 2 a.m.
Summary
Mendix Runtime contains an observable response discrepancy vulnerability when validating usernames during authentication. This could allow unauthenticated remote attackers to distinguish between valid and invalid usernames. Siemens has released new versions for the affected products and recommends to update to the latest versions.
Tuesday, 10.09.2024
Title
Rockwell Automation SequenceManager
Published
Sept. 10, 2024, 2 p.m.
Summary
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: SequenceManager Vulnerabilities: Unquoted Search Path or Element 2. RISK EVALUATION Successful exploitation of these vulnerabilities could cause a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of SequenceManager, a logix ...
Title
Viessmann Climate Solutions SE Vitogate 300
Published
Sept. 10, 2024, 2 p.m.
Summary
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity/public exploits are available Vendor: Viessmann Climate Solutions SE Equipment: Vitogate 300 Vulnerabilities: Use of Hard-coded Credentials, Forced Browsing, Command Injection 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to achieve remote code execution. ...
Title
iniNet Solutions SpiderControl SCADA Web Server
Published
Sept. 10, 2024, 2 p.m.
Summary
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: iniNet Solutions GmbH Equipment: SpiderControl SCADA Web Server Vulnerabilities: Unrestricted Upload of File with Dangerous Type 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to log in or execute arbitrary code. 3. ...
Title
SSA-446545 V1.0: Impact of RegreSSHion (CVE-2024-6387) in Siemens Industrial Products
Published
Sept. 10, 2024, 2 a.m.
Summary
An OpenSSH vulnerability, known as regreSSHion, affects multiple Siemens industrial products. This security regression vulnerability consists in a race condition which may allow an unauthenticated remote attacker to achieve remote code execution with high impact on the affected system. Siemens has released new versions for several affected products and recommends ...
Title
SSA-427715 V1.0: Stack-Based Buffer Overflow Vulnerability in Tecnomatix Plant Simulation
Published
Sept. 10, 2024, 2 a.m.
Summary
Siemens Tecnomatix Plant Simulation is affected by a stack-based buffer overflow vulnerability that could be triggered when the application reads files in SPP file format. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially ...
Title
SSA-423808 V1.0: Multiple NULL Pointer Dereference Vulnerabilities in Industrial Products
Published
Sept. 10, 2024, 2 a.m.
Summary
Multiple NULL pointer dereference vulnerabilities in the affected products could allow an attacker with network access to the webserver, to perform a denial of service attack. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where ...
Title
SSA-417159 V1.0: Multiple Vulnerabilities in SINEMA Remote Connect Client Before V3.2 SP2
Published
Sept. 10, 2024, 2 a.m.
Summary
SINEMA Remote Connect Client before V3.2 SP2 is affected by multiple vulnerabilities. Siemens has released a new version for SINEMA Remote Connect Client and recommends to update to the latest version.
Title
SSA-359713 V1.0: Authorization Bypass Vulnerability in Industrial Edge Management
Published
Sept. 10, 2024, 2 a.m.
Summary
Industrial Edge Management contains an Authorization Bypass vulnerability that could allow an unauthenticated remote attacker to impersonate other devices onboarded to the system. Siemens has released new versions for the affected products and recommends to update to the latest versions.
Title
SSA-349422 V2.1 (Last Update: 2024-09-10): Denial of Service Vulnerability in Industrial Real-Time (IRT) Devices
Published
Sept. 10, 2024, 2 a.m.
Summary
A vulnerability in the affected products could allow an unauthorized attacker with network access to perform a denial-of-service attack resulting in loss of real-time synchronization. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where updates are ...
Title
SSA-342438 V1.0: Privilege Escalation Vulnerability in SINUMERIK ONE, SINUMERIK 840D and SINUMERIK 828D
Published
Sept. 10, 2024, 2 a.m.
Summary
SINUMERIK ONE, SINUMERIK 840D sl and SINUMERIK 828D are affected by a privilege escalation vulnerability that could allow an authenticated local attacker to escalate their privileges in the underlying system. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures ...
Title
SSA-293562 V3.6 (Last Update: 2024-09-10): Denial of Service Vulnerabilities in PROFINET DCP Implementation of Industrial Products
Published
Sept. 10, 2024, 2 a.m.
Summary
Several industrial devices are affected by two vulnerabilities that could allow an attacker to cause a denial of service condition via PROFINET DCP network packets under certain circumstances. The precondition for this scenario is a direct layer 2 access to the affected products. PROFIBUS interfaces are not affected. Siemens has ...
Title
SSA-280603 V1.1 (Last Update: 2024-09-10): Denial of Service Vulnerability in SINUMERIK ONE and SINUMERIK MC
Published
Sept. 10, 2024, 2 a.m.
Summary
A vulnerability has been identified in the integrated S7-1500 CPU of SINUMERIK ONE and SINUMERIK MC products that could allow an attacker to cause a denial of service condition. In order to exploit the vulnerability, an attacker must have access to the affected devices on port 102/tcp. Siemens is preparing ...
Title
SSA-103653 V1.0: Denial-of-Service Vulnerability in Automation License Manager
Published
Sept. 10, 2024, 2 a.m.
Summary
A vulnerability was identified in the Automation License Manager software that could be triggered by sending specially crafted packets to port 4410/tcp of an affected system. This could cause a denial-of-service preventing legitimate users from using the system. Siemens has released a new version for Automation License Manager V6.2 and ...
Title
SSA-097786 V1.0: Insertion of Sensitive Information into Log File Vulnerability in SINUMERIK systems
Published
Sept. 10, 2024, 2 a.m.
Summary
SINUMERIK systems, that have been provisioned with Create MyConfig (CMC), are affected by a Insertion of Sensitive Information into Log File vulnerability. When using a CMC package on a NCU or on an IPC the password used in the CMC package or typed in manually during package execution is traced ...
Title
SSA-097435 V1.0: Usernames Disclosure Vulnerability in Mendix Runtime
Published
Sept. 10, 2024, 2 a.m.
Summary
Mendix Runtime contains an observable response discrepancy vulnerability when validating usernames during authentication. This could allow unauthenticated remote attackers to distinguish between valid and invalid usernames. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and ...
Title
SSA-088132 V1.1 (Last Update: 2024-09-10): Denial of Service Vulnerability in the OPC UA Server Implementations of Several Industrial Products
Published
Sept. 10, 2024, 2 a.m.
Summary
Unified Automation .NET based OPC UA Server SDK before 3.2.2 used in several industrial products are affected by a similar vulnerability as documented in CVE-2023-27321 for the OPC Foundation UA .NET Standard implementation. A successful attack may lead to high load situation and memory exhaustion, and may block the OPC ...
Title
SSA-039007 V1.0: Heap-based Buffer Overflow Vulnerability in User Management Component (UMC)
Published
Sept. 10, 2024, 2 a.m.
Summary
Siemens User Management Component (UMC) is affected by a heap-based buffer overflow vulnerability which could allow an unauthenticated remote attacker arbitrary code execution. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures ...
Title
SSA-792319 V1.1 (Last Update: 2024-09-10): Missing Read Out Protection in SENTRON 7KM PAC3x20 Devices
Published
Sept. 10, 2024, 2 a.m.
Summary
The read out protection of the internal flash of affected devices was not properly set at the end of the manufacturing process. An attacker with physical access to the device could read out the data. Siemens has released new versions for the affected products and recommends to update to the ...
Title
SSA-832273 V1.5 (Last Update: 2024-09-10): Multiple Vulnerabilities in Fortigate NGFW Before V7.4.3 on RUGGEDCOM APE1808 Devices
Published
Sept. 10, 2024, 2 a.m.
Summary
Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products. Siemens has released a new version of Fortigate NGFW for RUGGEDCOM APE1808 and recommends to update to the latest version. Siemens recommends to consult and implement the workarounds provided in Fortinet’s upstream security notifications.
Title
SSA-844582 V1.1 (Last Update: 2024-09-10): Electromagnetic Fault Injection in LOGO! V8.3 BM Devices Results in Broken LOGO! V8.3 Product CA
Published
Sept. 10, 2024, 2 a.m.
Summary
LOGO! V8.3 BM (incl. SIPLUS variants) devices contain a vulnerability that could allow an electromagnetic fault injection. This could allow an attacker to dump and debug the firmware, including the manipulation of memory. Further actions could allow to inject public keys of custom created key pairs which are then signed ...
Title
SSA-869574 V1.0: Multiple Vulnerabilities in SINEMA Remote Connect Server Before V3.2 SP2
Published
Sept. 10, 2024, 2 a.m.
Summary
SINEMA Remote Connect Server before V3.2 SP2 is affected by multiple vulnerabilities. Siemens has released a new version for SINEMA Remote Connect Client and recommends to update to the latest version.
Title
SSA-883918 V1.1 (Last Update: 2024-09-10): Information Disclosure Vulnerability in SIMATIC WinCC
Published
Sept. 10, 2024, 2 a.m.
Summary
Multiple versions of SIMATIC WinCC and SIMATIC PCS 7 do not properly handle certain requests to their web application (WinCC WebNavigator, PCS 7 Web Server, and PCS 7 Web Diagnostics Server), which may lead to the leak of privileged information. This could allow an unauthenticated remote attacker to retrieve information ...
Title
SSA-921449 V1.1 (Last Update: 2024-09-10): Plaintext Storage of a Password Vulnerability in LOGO! V8.3 BM Devices
Published
Sept. 10, 2024, 2 a.m.
Summary
LOGO! V8.3 BM (incl. SIPLUS variants) devices contain a plaintext storage of a password vulnerability. This could allow an attacker with phyiscal access to an affected device to extract user-set passwords from an embedded storage IC. Siemens has released new hardware versions with the LOGO! V8.4 BM and the SIPLUS ...