• 1
  • 2
  • 3 (current)
Tuesday, 13.05.2025
Title
SSA-556937 V1.0: Multiple Vulnerabilities in VersiCharge AC Series EV Chargers
Published
May 13, 2025, 2 a.m.
Summary
VersiCharge AC Series EV Chargers contain two vulnerabilities that could allow an attacker to gain control of the chargers through default Modbus port or execute arbitrary code by manipulating the M0 firmware. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens ...
Title
SSA-542540 V1.0: Out of Bounds Read Vulnerability in Teamcenter Visualization
Published
May 13, 2025, 2 a.m.
Summary
Siemens Teamcenter Visualization contains a out-of-bound read vulnerability that could be triggered when the application reads files in WRL format. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code execution. ...
Title
SSA-523418 V1.0: Information Disclosure Vulnerability in Desigo CC
Published
May 13, 2025, 2 a.m.
Summary
Desigo CC deployments that use Installed Client are impacted by an information disclosure vulnerability which could result in information leak from the Desigo CC server. The other Desigo CC client options, Windows App Client and Flex Client, are not affected by this vulnerability. Siemens recommends specific countermeasures for products where ...
Title
SSA-455250 V1.6 (Last Update: 2025-05-13): Multiple Vulnerabilities in Palo Alto Networks Virtual NGFW on RUGGEDCOM APE1808 Devices Before V11.1.2-h3
Published
May 13, 2025, 2 a.m.
Summary
Palo Alto Networks has published [1] information on vulnerabilities in PAN-OS. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens has released a new version of Palo Alto Networks Virtual NGFW for RUGGEDCOM APE1808 and recommends to update to the latest version. Customers are advised to ...
Title
SSA-446307 V1.0: Authentication Bypass Vulnerability in BMC (CVE-2024-54085) affects SIMATIC IPC RS-828A
Published
May 13, 2025, 2 a.m.
Summary
SIMATIC IPC RS-828A is affected by an authentication bypass vulnerability in the Redfish interface of its Baseboard Management Controller (BMC) that could allow an attacker to gain unauthorized access and compromise confidentiality, integrity and availability of the BMC and thus the entire system. Siemens is preparing fix versions and recommends ...
Title
SSA-373591 V1.1 (Last Update: 2025-05-13): Buffer Overflow Vulnerability in RUGGEDCOM ROS Devices
Published
May 13, 2025, 2 a.m.
Summary
The latest update for RUGGEDCOM ROS devices fixes a buffer overflow vulnerability in the third party component that could allow an attacker with network access to an affected device to cause a remote code execution condition. Siemens has released updates for the affected products and recommends to update to the ...
Title
SSA-366067 V1.3 (Last Update: 2025-05-13): Multiple Vulnerabilities in Fortigate NGFW Before V7.4.1 on RUGGEDCOM APE1808 Devices
Published
May 13, 2025, 2 a.m.
Summary
Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products. Siemens has released a new version for RUGGEDCOM APE1808 and recommends to update to the latest version. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or ...
Title
SSA-354569 V1.4 (Last Update: 2025-05-13): Multiple Vulnerabilities in Palo Alto Networks PAN-OS on RUGGEDCOM APE1808 Devices
Published
May 13, 2025, 2 a.m.
Summary
Palo Alto Networks has published [1] information on vulnerabilities in PAN-OS. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens is preparing fix versions and recommends countermeasures for products where fixes are not, or not yet available. [1] https://security.paloaltonetworks.com/
Title
SSA-339086 V1.0: Insufficient Session Expiration Vulnerability in SIMATIC PCS neo
Published
May 13, 2025, 2 a.m.
Summary
Affected products do not correctly invalidate user sessions upon user logout. This could allow a remote unauthenticated attacker, who has obtained the session token by other means, to re-use a legitimate user’s session even after logout. Siemens has released new versions for the affected products and recommends to update to ...
Title
SSA-327438 V1.0: Multiple Vulnerabilities in SCALANCE LPE9403
Published
May 13, 2025, 2 a.m.
Summary
SCALANCE LPE9403 is affected by multiple vulnerabilities which lead to a compromise in availability, integrity and confidentiality. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.
Title
SSA-222768 V1.0: Multiple Vulnerabilities in SIRIUS 3SK2 Safety Relays and 3RK3 Modular Safety Systems
Published
May 13, 2025, 2 a.m.
Summary
SIRIUS 3SK2 Safety Relays and 3RK3 Modular Safety Systems only provide weak password obfuscation. An attacker with access to the PROFINET or serial interface of the device could eavesdrop or read the stored password from the device and de-obfuscate it. The safety passwords work as protection against unauthorized operation (i.e., ...
Title
SSA-162255 V1.0: Multiple Vulnerabilities in Polarion Before V2410
Published
May 13, 2025, 2 a.m.
Summary
Polarion before V2410 contains multiple vulnerabilities that could allow attackers to extract data, conduct cross-site scripting attacks or find out valid usernames. Siemens strongly recommends to update Polarion to V2410 or later versions, not only to fix the documented vulnerabilities, but also to benefit from all the other improvements and ...
Title
SSA-103653 V1.1 (Last Update: 2025-05-13): Denial-of-Service Vulnerability in Automation License Manager
Published
May 13, 2025, 2 a.m.
Summary
A vulnerability was identified in the Automation License Manager software that could be triggered by sending specially crafted packets to port 4410/tcp of an affected system. This could cause a denial-of-service preventing legitimate users from using the system. Siemens has released new versions for several affected products and recommends to ...
Title
SSA-054046 V1.5 (Last Update: 2025-05-13): Unauthenticated Information Disclosure in Web Server of SIMATIC S7-1500 CPUs
Published
May 13, 2025, 2 a.m.
Summary
Several SIMATIC S7-1500 CPU versions are affected by an authentication bypass vulnerability that could allow an unauthenticated remote attacker to gain knowledge about actual and configured maximum cycle times and communication load of the CPU. Siemens has released new versions for several affected products and recommends to update to the ...
Title
SSA-047424 V1.0: Code Execution and SQL Injection Vulnerabilities in OZW Web Servers
Published
May 13, 2025, 2 a.m.
Summary
OZW672 and OZW772 Web Server versions contain vulnerabilities that could allow an attacker to execute arbitrary code on the device with root privileges (in versions before V8.0) or to authenticate as Administrator user (in versions before V6.0). Siemens has released new versions for the affected products and recommends to update ...
Title
SSA-039007 V1.5 (Last Update: 2025-05-13): Heap-based Buffer Overflow Vulnerability in User Management Component (UMC)
Published
May 13, 2025, 2 a.m.
Summary
Siemens User Management Component (UMC) is affected by a heap-based buffer overflow vulnerability which could allow an unauthenticated remote attacker arbitrary code execution. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures ...
Monday, 12.05.2025
Title
Russian GRU Targeting Western Logistics Entities and Technology Companies
Published
May 12, 2025, 6:49 p.m.
Summary
Executive Summary This joint cybersecurity advisory (CSA) highlights a Russian state-sponsored cyber campaign targeting Western logistics entities and technology companies. This includes those involved in the coordination, transport, and delivery of foreign assistance to Ukraine. Since 2022, Western logistics entities and IT companies have faced an elevated risk of targeting ...
Thursday, 08.05.2025
Title
Mitsubishi Electric CC-Link IE TSN
Published
May 8, 2025, 2 p.m.
Summary
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.2 ATTENTION: Exploitable remotely Vendor: Mitsubishi Electric Equipment: CC-Link IE TSN Remote I/O module, CC-Link IE TSN Analog-Digital Converter module, CC-Link IE TSN Digital-Analog Converter module, CC-Link IE TSN FPGA module, CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY Vulnerability: Improper ...
Tuesday, 06.05.2025
Title
Optigo Networks ONS NC600
Published
May 6, 2025, 2 p.m.
Summary
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Optigo Networks Equipment: ONS NC600 Vulnerability: Use of Hard-coded Credentials 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to establish an authenticated connection with the hard-coded credentials and perform OS command executions. ...
Title
Milesight UG65-868M-EA
Published
May 6, 2025, 2 p.m.
Summary
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 6.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Milesight Equipment: UG65-868M-EA Vulnerability: Improper Access Control for Volatile Memory Containing Boot Code 2. RISK EVALUATION Successful exploitation of this vulnerability could allow any user with admin privileges to inject arbitrary shell commands. 3. TECHNICAL DETAILS ...
Title
BrightSign Players
Published
May 6, 2025, 2 p.m.
Summary
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: BrightSign Equipment: Brightsign Players Vulnerabilities: Execution with Unnecessary Privileges 2. RISK EVALUATION Successful exploitation of this vulnerability could allow for privilege escalation on the device, easily guessed passwords, or for arbitrary code to be executed on ...
Thursday, 01.05.2025
Title
KUNBUS GmbH Revolution Pi
Published
May 1, 2025, 2 p.m.
Summary
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: KUNBUS Equipment: Revolution Pi Vulnerabilities: Missing Authentication for Critical Function, Authentication Bypass by Primary Weakness, Improper Neutralization of Server-Side Includes (SSI) Within a Web Page 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow attackers ...