Bulletins

SIEMENS CERT
08/12/2025
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version >= V3.1.0 and < V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens has released new versions for the affected products and recommends to update …
SIEMENS CERT
08/12/2025
An information disclosure vulnerability in SIPROTEC 5 devices could allow an unauthenticated, remote attacker to retrieve sensitive information of the device. Siemens has released new versions for the affected products and recommends to update to the latest versions.
SIEMENS CERT
08/12/2025
SCALANCE XB-200/XC-200/XP-200/XF-200BA/XR-300WG Family is affected by multiple vulnerabilities. CVE-2023-44318 and CVE-2023-44321 were previously published as part of SSA-699386. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures for products where fixes are not, or not yet available.
SIEMENS CERT
08/12/2025
Affected SIPROTEC 5 devices contain a development shell which is accessible via a physical interface which is not properly restricted. This could allow an unauthenticated attacker with physical access to an affected device to execute arbitrary commands on the device. Siemens has released new versions for several affected products and …
SIEMENS CERT
08/12/2025
Fortinet has published information on vulnerabilities in FortiOS. This advisory lists the related Siemens Industrial products. Siemens is preparing fix versions and recommends to consult and implement the workarounds provided in Fortinet’s upstream security notifications.
SIEMENS CERT
08/12/2025
SIMATIC RTLS Locating Manager Before V3.2 contains an improper input validation vulnerability that could allow an authenticated remote attacker to execute arbitrary code with high privileges. Siemens has released a new version for SIMATIC RTLS Locating Manager and recommends to update to the latest version.
SIEMENS CERT
08/12/2025
The RUGGEDCOM RCDP protocol is not properly configured after commissioning of RUGGEDCOM ROS based devices and some SCALANCE X switch models and could allow unauthenticated remote users to perform administrative operations. An attacker must be in the same adjacent network and the RCDP daemon must be enabled in order to …
SIEMENS CERT
08/12/2025
Affected SIPROTEC 5 devices do not properly limit the bandwidth for incoming network packets over their local USB port. This could allow an attacker with physical access to send specially crafted packets with high bandwidth to the affected devices thus forcing them to exhaust their memory and stop responding to …