September 2022
Title
Delta Industrial Automation DIAEnergie
Published
Sept. 13, 2022, 4:15 p.m.
Summary
This advisory contains mitigations for a Use of Hard-coded Credentials vulnerability in verisons of DIAEnergie, an industrial energy management system.
Title
Kingspan TMS300 CS
Published
Sept. 13, 2022, 4:10 p.m.
Summary
This advisory contains mitigations for an Improper Authentication vulnerability in Kingsapn TMS300 CS, a water tank management system.
Title
Hitachi Energy TXpert Hub CoreTec 4 Sudo Vulnerability
Published
Sept. 13, 2022, 4 p.m.
Summary
This advisory contains mitigations for an Off-by-one Error vulnerability in versions of Hitachi Energy TXpert Hub CoreTec 4, a digital transformer monitoring and diagnostics device.
Title
Honeywell SoftMaster
Published
Sept. 13, 2022, 4 p.m.
Summary
This advisory contains mitigations for Uncontrolled Search Path Element and Incorrect Permission Assignment for Critical Resource vulnerabilities in the SoftMaster desktop application, a PLC software application.
Title
Baxter Sigma Spectrum Infusion Pump
Published
Sept. 8, 2022, 4:20 p.m.
Summary
This advisory contains mitigations for Missing Encryption of Sensitive Data, Use of Externally Controlled Format String, Missing Authentication for Critical Function vulnerabilities in Sigma and Baxter Spectrum Infusion Pumps.
Title
MZ Automation libIEC61850
Published
Sept. 8, 2022, 4:15 p.m.
Summary
This advisory contains mitigations for Buffer Overflow, Access of Resource Using Incompatible Type, NULL Pointer Dereference vulnerabilities in libIEC61850 of IEC61850 implementation software.
Title
Hillrom Medical Device Management (Update B)
Published
Sept. 8, 2022, 4:05 p.m.
Summary
This updated advisory is a follow-up to the original advisory titled ICSMA-21-152-01 Hillrom Medical Device Management (Update A) that was published June 1, 2021, to the ICS webpage at cisa.gov/ics. This advisory contains mitigations for Out-of-bounds Write, Out-of-bounds Read vulnerabilities in Welch Allyn medical device management tools.
Title
PTC Kepware KEPServerEX (Update A)
Published
Sept. 8, 2022, 4 p.m.
Summary
This updated advisory is a follow-up to the original advisory titled ICSA-22-242-10 PTC Kepware KEPServerEX that was published August 30, 2022, to the ICS webpage at www.cisa.gov/ics. This advisory contains mitigations for Kepware KEPServerEX vulnerabilities in Heap-based Buffer Overflow, Stack-based Buffer Overflow.
Title
Triangle Microworks Libraries
Published
Sept. 6, 2022, 4:50 p.m.
Summary
This advisory contains mitigations for Access of Uninitialized Pointer vulnerabilities in Triangle Microworks, TMW IEC 61850 Software Library and TMW IEC 60870-6 (ICCP/TASE.2) Software Library.
Title
AVEVA Edge 2020 R2 SP1 and all prior versions
Published
Sept. 6, 2022, 4:40 p.m.
Summary
This advisory contains mitigations for Insufficient UI Warning of Dangerous Operations, Uncontrolled Search Path Element, and Deserialization of Untrusted Data, Improper Restriction of XML External Entity Reference vulnerabilities in versions of AVEVA Edge, an industrial software system.
Title
Cognex 3D-A1000 Dimensioning System
Published
Sept. 6, 2022, 4:20 p.m.
Summary
This advisory contains mitigations for Missing Authentication for Critical Function, Improper Output Neutralization for Logs, and Client-side Enforcement of Server-side Security vulnerabilities in versions of Cognex 3DS-A1000 Dimensioning System, an industrial smart camera.
Title
Hitachi Energy TXpert Hub CoreTec 4
Published
Sept. 6, 2022, 4:10 p.m.
Summary
This advisory contains mitigations for Authentication Bypass Using an Alternate Path or Channel and Improper Input Validation, Download of Code Without Integrity Check vulnerabilities in versions of Hitachi Energy TXpert Hub CoreTec 4, a digital transformer monitoring and diagnostics device.
Title
Delta Electronics DOPSoft 2 (Update A)
Published
Sept. 6, 2022, 4 p.m.
Summary
This updated advisory is a follow-up to the advisory update titled ICSA-21-252-02 Delta Electronics DOPSoft2 that was published September 09, 2021, to the ICS webpage on cisa.gov/ics. This advisory contains mitigations for Stack-based Buffer Overflow, Out-of-Bounds Write, and Heap-based Buffer Overflow vulnerabilities in Delta Electronics DOPSoft 2 HMI editing software.
Title
Contec Health CMS8000
Published
Sept. 1, 2022, 4:10 p.m.
Summary
This advisory contains mitigations for Improper Access Control, Uncontrolled Resource Consumption, Use of Hard-Coded Credentials, Active Debug Code vulnerabilities in Contec Health CMS8000, a ICU CCU Vital Signs Patient Monitor.
August 2022
Title
Hitachi Energy FACTS Control Platform (FCP) Product
Published
Aug. 30, 2022, 4:55 p.m.
Summary
This advisory contains mitigations for Inconsistent Interpretation of HTTP Requests, Use After Free, Classic Buffer Overflow, Integer Underflow, Improper Certificate Validation, Observable Discrepancy vulnerabilities in Hitachi Energy FACTS Control Platform (FCP).
Title
Hitachi Energy Gateway Station (GWS) Product
Published
Aug. 30, 2022, 4:50 p.m.
Summary
This advisory contains mitigations for a Hitachi Energy Gateway Station (GWS) Product vulnerability in Inconsistent Interpretation of HTTP Requests, Use After Free, Classic Buffer Overflow, Integer Underflow, Improper Certificate Validation, Observable Discrepancy.
Title
Hitachi Energy MSM Product
Published
Aug. 30, 2022, 4:40 p.m.
Summary
This advisory contains mitigations for a Hitachi Energy MSM Product vulnerability in Reliance on Uncontrolled Component.
Title
Fuji Electric D300win
Published
Aug. 30, 2022, 4:30 p.m.
Summary
This advisory contains mitigations for a Fuji Electric D300win vulnerability Out-of-bounds Read, Write-what-where Condition
Title
Honeywell ControlEdge
Published
Aug. 30, 2022, 4:30 p.m.
Summary
This advisory contains mitigations for a Honeywell ControlEdge vulnerability Missing Authentication for Critical Function.
Title
Honeywell Experion LX
Published
Aug. 30, 2022, 4:25 p.m.
Summary
This advisory contains mitigations for a Missing Authentication for Critical Function vulnerability in versions of the Honeywell equipment, Experion LX, distributed control system (DCS).
Title
Honeywell Trend Controls Inter-Controller Protocol
Published
Aug. 30, 2022, 4:20 p.m.
Summary
This advisory contains mitigations for a Cleartext Transmission of Sensitive Information vulnerability in versions of the Honeywell products, Trend Controls IQ Series IC, an industrial communication controller.
Title
PTC Kepware KEPServerEX
Published
Aug. 30, 2022, 4:10 p.m.
Summary
This advisory contains mitigations for Heap-Based Buffer Overflow and Stack-Based Buffer Overflow vulnerabilities in versions of the PTC product, Kepware KEPServerEX, a connectivity platform.
Title
Measuresoft ScadaPro Server and Client
Published
Aug. 23, 2022, 5:06 p.m.
Summary
This advisory contains mitigations for Untrusted Pointer Dereference, Stack-based Buffer Overflow, Use After Free, and Link Following vulnerabilities in Measuresoft ScadaPro Server and Client, a supervisory control and data acquisition (SCADA) system.
Title
Measuresoft ScadaPro Server
Published
Aug. 23, 2022, 5:04 p.m.
Summary
This advisory contains mitigations for an Out-of-bounds Write vulnerability in Measuresoft ScadaPro Server, a supervisory control and data acquisition (SCADA) system.
Title
Hitachi Energy RTU500
Published
Aug. 23, 2022, 5:02 p.m.
Summary
This advisory contains mitigations for a Stack-based Buffer Overflow vulnerability in versions of Hitatchi Energy RTU500 firmware.

Last Updates

BOSCH PSIRT
31.10.2024
SIEMENS CERT
22.11.2024
US CERT
08.11.2024
US CERT (ICS)
21.11.2024

By Source

Archive

2024
2023
2022
2021
2020
2019
2018
2017

Feeds