April 2020
Title
Synergy Systems & Solutions HUSKY RTU (Update A)
Published
April 7, 2020, 4 p.m.
Summary
This updated advisory is a follow-up to the original advisory titled ICSA-20-042-01 Synergy Systems & Solutions HUSKY RTU that was published February 11, 2020, to the ICS webpage on us-cert.gov. This advisory contains mitigations for improper authentication and improper input validation vulnerabilities in Synergy Systems & Solutions HUSKY RTU, a ...
Title
B&R Automation Studio
Published
April 2, 2020, 4 p.m.
Summary
This advisory contains mitigations for improper privilege management, missing required cryptographic step, and path traversal vulnerabilities in B&R Automation Studio software.
March 2020
Title
BD Pyxis MedStation and Pyxis Anesthesia (PAS) ES System
Published
March 31, 2020, 4:15 p.m.
Summary
This advisory contains mitigations for a protection mechanism failure vulnerability in BD Pyxis medical devices.
Title
Hirschmann Automation and Control HiOS and HiSecOS Products
Published
March 31, 2020, 4:10 p.m.
Summary
This advisory contains mitigations for a classic buffer overflow vulnerability in Hirschmann Automation and Control HiOS and HiSecOS software.
Title
Mitsubishi Electric MELSEC
Published
March 31, 2020, 4:05 p.m.
Summary
This advisory contains mitigations for an uncontrolled resource consumption vulnerability in Mitsubishi Electric MELSEC programmable controllers.
Title
Schneider Electric Modicon Controllers (Update A)
Published
March 31, 2020, 4 p.m.
Summary
This updated advisory is a follow-up to the original advisory titled ICSA-20-016-01 Schneider Electric Modicon Controllers that was published January 16, 2020, to the ICS webpage on us-cert.gov. This advisory contains mitigations for several improper check for unusual or exceptional conditions vulnerabilities in Schneider Electric Modicon PLC controllers.
Title
VISAM Automation Base (VBASE)
Published
March 24, 2020, 3:05 p.m.
Summary
This advisory contains mitigations for several vulnerabilities in VISAM's VBASE automation platform.
Title
Insulet Omnipod
Published
March 19, 2020, 3:05 p.m.
Summary
This advisory contains mitigations for an improper access control vulnerability in Insulet's Omnipod insulin management system.
Title
Systech NDS-5000 Terminal Server
Published
March 19, 2020, 3 p.m.
Summary
This advisory contains mitigations for a cross-site scripting vulnerability in Systech's NDS-5000 network server.
Title
Delta Electronics Industrial Automation CNCSoft ScreenEditor
Published
March 17, 2020, 3 p.m.
Summary
This advisory contains mitigations for stack-based buffer overflow and out-of-bounds read vulnerabilities in the Delta Electronics Industrial Automation CNCSoft user interface.
Title
ABB Asset Suite
Published
March 12, 2020, 3:05 p.m.
Summary
This advisory contains mitigations for an authorization bypass through user-controlled key vulnerability in ABB Asset Suite software.
Title
SIMATIC S7-300 CPUs and SINUMERIK Controller over Profinet
Published
March 10, 2020, 4:25 p.m.
Summary
This advisory contains mitigations for an uncontrolled resource consumption vulnerability in Siemens SIMATIC and SINUMERIK controllers.
Title
Siemens Spectrum Power 5
Published
March 10, 2020, 4:20 p.m.
Summary
This advisory contains mitigations for a basic cross-site scripting (XSS) vulnerability in the Siemens Spectrum Power 5 grid control system.
Title
Johnson Controls Kantech EntraPass
Published
March 10, 2020, 4:15 p.m.
Summary
This advisory contains mitigations for an improper input validation vulnerability in the Johnson Controls Kantech EntraPass security management software.
Title
Rockwell Automation MicroLogix Controllers and RSLogix 500 Software
Published
March 10, 2020, 4:05 p.m.
Summary
This advisory contains mitigations for use of hard-coded cryptographic key, use of a broken or risky algorithm for password protection, use of client-side authentication,and cleartext storage of sensitive information vulnerabilities in Rockwell Automation's MicroLogix products.
Title
Siemens PROFINET-IO Stack (Update A)
Published
March 10, 2020, 4 p.m.
Summary
This updated advisory is a follow-up to the original advisory titled ICSA-20-042-04 Siemens PROFINET-IO Stack that was published February 11, 2020, to the ICS webpage on us-cert.gov. This advisory contains mitigations for an internal resource allocation vulnerability in the Siemens PROFINET-IO Stack, which could be exploited to create a denial-of-service ...
Title
Siemens SIMATIC S7 (Update A)
Published
March 10, 2020, 3:55 p.m.
Summary
This updated advisory is a follow-up to the original advisory titled ICSA-20-042-05 Siemens SIMATIC S7 that was published February 11, 2020, to the ICS webpage on us-cert.gov. This advisory contains mitigations for a resource exhaustion vulnerability in Siemens SIMATIC S7 devices.
Title
Siemens SIMATIC PCS 7, SIMATIC WinCC, and SIMATIC NET PC (Update A)
Published
March 10, 2020, 3:50 p.m.
Summary
This updated advisory is a follow-up to the original advisory titled ICSA-19-042-06 ICSA-20-042-06 Siemens SIMATIC PCS 7, SIMATIC WinCC, and SIMATIC NET PC that was published February 11, 2020, to the ICS webpage on us-cert.gov. This advisory contains mitigations for an incorrect calculation of buffer size vulnerability in some Siemens ...
Title
Siemens SIMATIC S7-1500 (Update A)
Published
March 10, 2020, 3:45 p.m.
Summary
This updated advisory is a follow-up to the original advisory titled ICSA-20-042-11 Siemens SIMATIC S7-1500 that was published February 11, 2020, to the ICS webpage on us-cert.gov. This advisory contains mitigations for a resource exhaustion vulnerability in Siemens SIMATIC S7-1500 CPU family.
Title
WAGO I/O-CHECK
Published
March 5, 2020, 4 p.m.
Summary
This advisory contains mitigations for information exposure through sent data, buffer access with incorrect length value, missing authentication for critical function, and classic buffer overflow vulnerabilities in the WAGO I/O CHECK software.
Title
SweynTooth Vulnerabilities
Published
March 3, 2020, 4:20 p.m.
Summary
This ALERT details vulnerabilities in SweynTooth's Bluetooth Low Energy (BLE) proof-of-concept (PoC) exploit code. This report was released without coordination with some of the affected vendors and without advance coordination with CISA. CISA has notified some of the affected vendors of the report and has asked the vendors to confirm ...
Title
Emerson ValveLink
Published
March 3, 2020, 4:15 p.m.
Summary
This advisory contains mitigations for an improper access control vulnerability in Emerson's ValveLink digital valve controllers.
Title
PHOENIX CONTACT Emalytics Controller ILC
Published
March 3, 2020, 4:10 p.m.
Summary
This advisory contains mitigations for an incorrect permission assignment for critical resource vulnerability in Phoenix Contact's Emalytics Controller modular inline devices.
Title
Omron PLC CJ Series
Published
March 3, 2020, 4:05 p.m.
Summary
This advisory contains mitigations for an uncontrolled resource consumption vulnerability in Omron's PLC CJ Series programmable logic controllers.
Title
Moxa AWK-3131A Series Industrial AP/Bridge/Client
Published
March 3, 2020, 4 p.m.
Summary
This advisory contains mitigations for several vulnerabilities in Moxa's AWK-3131A wireless networking appliance.

Last Updates

BOSCH PSIRT
31.10.2024
SIEMENS CERT
22.11.2024
US CERT
08.11.2024
US CERT (ICS)
21.11.2024

By Source

Archive

2024
2023
2022
2021
2020
2019
2018
2017

Feeds