VDE-2022-038
Okt. 1, 2025, 12:50 nachm.
A vulnerability was reported in WIBU-SYSTEMS CodeMeter Runtime. WIBU-SYSTEMS CodeMeter Runtime is part of the installation packages of several Festo products.FluidDraw < 6.2c and CIROS <= 7.0.6 contain a …
VDE-2022-041
Nov. 3, 2025, 11:00 vorm.
Incomplete Festo product documentation of remote accessible functions and their required IP ports. Depending on the product a description of the supported features can be found in the product documentation …
VDE-2022-037
Okt. 28, 2025, 12:00 nachm.
The products are shipped with an unsafe configuration of the integrated CODESYS Runtime environment. In this case no default password is set to the CODESYS PLC and therefore access without …
VDE-2022-036
Juli 28, 2025, 12:00 nachm.
Unauthenticated access to critical webpage functions (e.g. reboot) may cause a denial of service of the device.
VDE-2022-022
Nov. 3, 2025, 12:00 nachm.
The Festo controller CECC product family is affected by multiple vulnerabilities in the CODESYS V3 runtime.
VDE-2022-027
Juli 10, 2025, 12:00 nachm.
The Festo controller CECC product family in firmware version 2.4.2.0 is affected by multiple vulnerabilities in the CODESYS V3 runtime.
VDE-2022-020
Juni 23, 2025, 10:00 vorm.
The Festo controller CECC-X-M1 product family in multiple versions are affected by a preauthentication command injection vulnerability. Update A, 2022-07-05 Remediation has been updated. Fixed firmwares are now available.
VDE-2021-045
Aug. 26, 2025, 12:00 nachm.
The affected product families are cameras SBOC/SBOI and the Controller SBRD. The vulnerabilities are located within the Ethernet IP Stack from EIPStackGroup OpENer Ethernet/IP.