Januar 2020
Titel
SSA-632562 (Last Update: 2020-01-14): Vulnerabilities in SIPROTEC 5 Ethernet plug-in communication modules and devices
Veröffentlicht
14. Januar 2020 01:00
Text
The SIPROTEC 5 Ethernet plug-in communication modules and devices are affected by multiple security vulnerabilities. These vulnerabilities could allow an attacker to leverage various attacks, e.g. to execute arbitrary code over the network. The underlying Wind River VxWorks network stack is affected by eleven vulnerabilities known as 'URGENT/11'. Of these, ...
Titel
SSA-349422 (Last Update: 2020-01-14): Denial-of-Service in Industrial Real-Time (IRT) Devices
Veröffentlicht
14. Januar 2020 01:00
Text
A vulnerability in the affected products could allow an unauthorized attacker with network access to perform a denial-of-service attack resulting in loss of real-time synchronization. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates and recommends specific ...
Titel
SSA-181018 (Last Update: 2020-01-14): Heap Overflow Vulnerability in SCALANCE X switches, RUGGEDCOM Win, RFID 181-EIP, and SIMATIC RF182C
Veröffentlicht
14. Januar 2020 01:00
Text
SCALANCE X switches, RUGGEDCOM Win, RFID 181-EIP, and SIMATIC RF182C are affected by a vulnerability that could allow an unprivileged attacker located in the same local network segment (OSI Layer 2) to gain system privileges by sending a specially crafted DHCP response to a client's DHCP request. Siemens has released ...
Titel
SSB-439005 (Last Update: 2020-01-14): Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP
Veröffentlicht
14. Januar 2020 01:00
Text
Titel
SSA-473245 (Last Update: 2020-01-14): Denial-of-Service Vulnerability in Profinet Devices
Veröffentlicht
14. Januar 2020 01:00
Text
A vulnerability in affected devices could allow an attacker to perform a denial-of-service attack if a large amount of specially crafted UDP packets are sent to the device. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates ...
Titel
SSA-629512 (Last Update: 2020-01-14): Local Privilege Escalation Vulnerability in TIA Portal
Veröffentlicht
14. Januar 2020 01:00
Text
The latest update for TIA Portal fixes a vulnerability that could allow a local attacker to execute arbitrary code with SYSTEM privileges. Siemens has released an update for TIA Portal V15, is working on updates for other versions of TIA Portal and recommends specific mitigations for vulnerable versions.
Titel
SSA-418979 (Last Update: 2020-01-14): Vulnerabilities in EN100 Ethernet Communication Module
Veröffentlicht
14. Januar 2020 01:00
Text
The EN100 Ethernet communication modules are affected by security vulnerabilities which could allow an attacker to disclose information. Siemens has released updates for several affected products, is working on updates for the remaining affected products, and recommends specific countermeasures until fixes are available.
Titel
SSA-646841 (Last Update: 2020-01-14): Recoverable Password from Configuration Storage in SCALANCE X Switches
Veröffentlicht
14. Januar 2020 01:00
Text
A vulnerability exists in several SCALANCE X switches that could allow external entities to reconstruct passwords for users of the affected devices if an attacker is able to obtain a backup of the device configuration. Siemens has released updates for some of the affected devices and is working on updates ...
Titel
SSA-307392 (Last Update: 2020-01-14): Denial-of-Service in OPC UA in Industrial Products
Veröffentlicht
14. Januar 2020 01:00
Text
A vulnerability has been identified in the OPC UA server of several industrial products. The vulnerability could cause a Denial-of-Service condition on the service or the device. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates and ...
Titel
Interpeak IPnet TCP/IP Stack (Update D)
Veröffentlicht
7. Januar 2020 16:00
Text
This updated medical advisory is a follow-up to the advisory update titled ICSMA-19-274-01 Interpeak IPnet TCP/IP Stack (Update C) published November 5, 2019, on the ICS webpage on us-cert.gov. This updated medical advisory contains mitigations for stack-based buffer overflow, heap-based buffer overflow, integer underflow, improper restriction of operations within the ...
Dezember 2019
Titel
Philips Veradius Unity, Pulsera, and Endura Dual WAN Routers
Veröffentlicht
19. Dezember 2019 16:30
Text
This advisory contains mitigations for an inadequate encryption strength vulnerability in certain Philips WAN routers.
Titel
Moxa EDS Ethernet Switches
Veröffentlicht
19. Dezember 2019 16:25
Text
This advisory contains mitigations for an uncontrolled resource consumption vulnerability in Moxa EDS Ethernet Switches.
Titel
Equinox Control Expert
Veröffentlicht
19. Dezember 2019 16:20
Text
This advisory contains mitigations for an SQL injection vulnerability in Equinox's Control Expert HMI/SCADA management platform.
Titel
Reliable Controls MACH-ProWebCom/Sys
Veröffentlicht
19. Dezember 2019 16:10
Text
This advisory contains mitigations for a cross-site scripting vulnerability in Reliable Controls' MACH-ProWebCom/Sys web enabled building controllers.
Titel
AVEVA Vijeo Citect and Citect SCADA (Update A)
Veröffentlicht
19. Dezember 2019 16:00
Text
This updated advisory is a follow-up to the original advisory titled “ICSA-19-290-01 AVEVA Vijeo Citect and Citect SCADA” that was published October 17, 2019, on the ICS webpage on us-cert.gov. This advisory contains mitigations for a stack-based buffer overflow vulnerability in the AVEVA Vijeo Citect and Citect SCADA.
Titel
GE S2020/S2020G Fast Switch 61850
Veröffentlicht
17. Dezember 2019 16:05
Text
This advisory contains mitigations for a cross-site scripting vulnerability in GE's S2020/S2020G Fast Switch 61850 Ethernet switches.
Titel
Siemens SPPA-T3000
Veröffentlicht
17. Dezember 2019 16:00
Text
This advisory contains mitigations for numerous vulnerabilities in Siemens' SPPA-T3000 servers.
Titel
Siemens SCALANCE W700 and W1700
Veröffentlicht
10. Dezember 2019 17:05
Text
This advisory contains mitigations for an improper enforcement of message integrity during transmission in a communication channel vulnerability in the Siemens SCALANCE W700 and W1700 wireless communication devices.
Titel
Siemens SiNVR 3
Veröffentlicht
10. Dezember 2019 17:00
Text
This advisory contains mitigations for cleartext storage of sensitive information in GUI, improper authentication, relative path traversal, missing authentication for critical function, weak cryptography for passwords, and exposed dangerous method or function vulnerabilities in the Siemens SiNVR 3 video management solution.
Titel
Siemens RUGGEDCOM ROS
Veröffentlicht
10. Dezember 2019 16:55
Text
This advisory contains mitigations for improper restriction of operations within the bounds of a memory buffer and resource management errors vulnerabilities in the Siemens RUGGEDCOM ROS ethernet switch.
Titel
Siemens SIMATIC Products
Veröffentlicht
10. Dezember 2019 16:50
Text
This advisory contains mitigations for an exposed dangerous method or function vulnerability in Siemens' SIMATIC products.
Titel
Siemens XHQ Operations Intelligence
Veröffentlicht
10. Dezember 2019 16:45
Text
This advisory contains mitigations for cross-site request forgery, improper neutralization of script-related HTML tags in a web page, and improper input validation vulnerabilities in the Siemens XHQ Operations Intelligence products.
Titel
Siemens SIMATIC S7-1200 and S7-1500 CPU Families
Veröffentlicht
10. Dezember 2019 16:40
Text
This advisory contains mitigations for a use of a broken or risky cryptographic algorithm, and missing support for integrity check vulnerabilities in the Siemens SIMATIC S7-1200 and S7-1500 CPU families.
Titel
Siemens S7-1200 and S7-200 SMART CPUs (Update A)
Veröffentlicht
10. Dezember 2019 16:30
Text
This updated advisory is a follow-up to the original advisory titled ICSA-19-318-02 Siemens S7-1200 that was published November 14, 2019, on the ICS webpage on us-cert.gov. This advisory contains information and mitigation recommendations for an exposed dangerous method or function vulnerability in the Siemens S7-1200 and S7-200 SMART CPUs.
Titel
Interpeak IPnet TCP/IP Stack (Update B)
Veröffentlicht
10. Dezember 2019 16:25
Text
This updated advisory is a follow-up to the updated advisory titled ICSA-19-274-01 Interpeak IPnet TCP/IP Stack (Update A) that was published October 10, 2019, on the ICS webpage on us-cert.gov. This advisory contains mitigations for stack-based buffer overflow, heap-based buffer overflow, integer underflow, improper restriction of operations within the bounds ...

Letzte Updates

BOSCH PSIRT
15.01.2025
SIEMENS CERT
15.01.2025
US CERT
15.01.2025
US CERT (ICS)
21.01.2025

Nach Quelle

Archiv

2025
2024
2023
2022
2021
2020
2019
2018
2017

Feeds