März 2021
Titel
Side Channel Key Extraction Vulnerability in Bosch IP Cameras and Encoders
Veröffentlicht
2. März 2021 01:00
Text

BOSCH-SA-762869-BT: A recently discovered side channel attack for the NXP P5x security microcontrollers was made public. It allows attackers to extract an ECDSA private key after extensive physical access to the chip. The P5x is used as secure certificate storage on Bosch cameras and encoders built on platforms CPP-ENC CPP3 ...

Februar 2021
Titel
PerFact OpenVPN-Client
Veröffentlicht
25. Februar 2021 16:15
Text
This advisory contains mitigations for an External Control of System or Configuration Setting vulnerability in the PerFact OpenVPN-Client.
Titel
Fatek FvDesigner
Veröffentlicht
25. Februar 2021 16:10
Text
This advisory contains mitigations for Use After Free, Access of Uninitialized Pointer, Stack-based Buffer Overflow, Out-of-Bounds Write, and Out-of-Bounds Read vulnerabilities in Fatek FvDesigner software.
Titel
Rockwell Automation Logix Controllers
Veröffentlicht
25. Februar 2021 16:05
Text
This advisory contains mitigations for a n Insufficiently Protected Credentials vulnerability in Rockwell Automation Studio 5000 Logix Designer, RSLogix 5000, and Logix Controllers.
Titel
ProSoft Technology ICX35
Veröffentlicht
25. Februar 2021 16:00
Text
This advisory contains mitigations for a Permissions, Privileges, and Access Controls vulnerability in ProSoft Technology ICX35 industrial cellular gateways.
Titel
AA21-055A: Exploitation of Accellion File Transfer Appliance
Veröffentlicht
24. Februar 2021 15:00
Text
Original release date: February 24, 2021 | Last revised: February 25, 2021SummaryThis joint advisory is the result of a collaborative effort by the cybersecurity authorities of Australia,[1] New Zealand,[2] Singapore,[3] the United Kingdom,[4] and the United States.[5][6] These authorities are aware of cyber actors exploiting vulnerabilities in Accellion File Transfer ...
Titel
Privilege Escalation via sudo and Linux kernel in Bosch Rexroth Products
Veröffentlicht
24. Februar 2021 01:00
Text

BOSCH-SA-372917: Linux kernel versions through 5.10.11 contain weaknesses which allow local users to execute code in the kernel with the potential to escalate privileges [1][2]. In versions of sudo before 1.9.5p2 there is a weakness present which allows privilege escalation to root for local users [3]. The ctrlX CORE and ...

Titel
Advantech BB-ESWGP506-2SFP-T
Veröffentlicht
23. Februar 2021 16:05
Text
This advisory contains mitigations for a Use of Hard-coded Credentials vulnerability in Advantech BB-ESWGP506-2SFP-T industrial ethernet switches.
Titel
Advantech Spectre RT Industrial Routers
Veröffentlicht
23. Februar 2021 16:00
Text
This advisory contains mitigations for Improper Neutralization of Input During Web Page Generation, Cleartext Transmission of Sensitive Information, Improper Restriction of Excessive Authentication Attempts, Use of a Broken or Risky Cryptographic Algorithm, and Use of Platform-Dependent Third-party Components vulnerabilities in Advantech Spectre RT Industrial Routers.
Titel
AA21-048A: AppleJeus: Analysis of North Korea’s Cryptocurrency Malware
Veröffentlicht
17. Februar 2021 17:00
Text
Original release date: February 17, 2021 | Last revised: March 2, 2021SummaryThis Advisory uses the MITRE Adversarial Tactics, Techniques, and Common Knowledge (ATT&CK®) framework. See the ATT&CK for Enterprise for all referenced threat actor tactics and techniques. This joint advisory is the result of analytic efforts among the Federal Bureau ...
Titel
AA21-042A: Compromise of U.S. Water Treatment Facility
Veröffentlicht
11. Februar 2021 20:15
Text
Original release date: February 11, 2021 | Last revised: February 12, 2021SummaryOn February 5, 2021, unidentified cyber actors obtained unauthorized access to the supervisory control and data acquisition (SCADA) system at a U.S. drinking water treatment facility. The unidentified actors used the SCADA system’s software to increase the amount of ...
Titel
Multiple Embedded TCP/IP stacks
Veröffentlicht
11. Februar 2021 16:10
Text
This advisory contains mitigations for Use of Insufficiently Random Values vulnerabilities in Nut/Net, CycloneTCP, NDKTCPIP, FNET, uIP-Contiki-OS, uC/TCP-IP, uIP-Contiki-NG, uIP, picoTCP-NG, picoTCP, MPLAB Net, Nucleus NET, Nucleus ReadyStart TCP/IP stacks.
Titel
Rockwell Automation DriveTools SP and Drives AOP
Veröffentlicht
11. Februar 2021 16:05
Text
This advisory contains mitigations for an Uncontrolled Search Path Element vulnerability in Rockwell Automation DriveTools SP and Drives AOP software.
Titel
Wibu-Systems CodeMeter (Update E)
Veröffentlicht
11. Februar 2021 16:00
Text
This updated advisory is a follow-up to the advisory update titled ICSA-20-203-01 Wibu-Systems CodeMeter (Update D) that was published December 3, 2020, to the ICS webpage on us-cert.gov. This advisory contains mitigations for Buffer Access with Incorrect Length Value, Inadequate Encryption Strength, Origin Validation Error, Improper Input Validation, Improper Verification ...
Titel
GE Digital HMI/SCADA iFIX
Veröffentlicht
9. Februar 2021 17:50
Text
This advisory contains mitigations for Incorrect Permission Assignment for Critical Resource vulnerabilities in the GE Digital HMI/SCADA iFIX software component.
Titel
Siemens SINEMA Server & SINEC NMS
Veröffentlicht
9. Februar 2021 17:40
Text
This advisory contains mitigations for a Path Traversal vulnerability in Siemens SINEMA server and SINEC NMS products.
Titel
Siemens TIA Administrator
Veröffentlicht
9. Februar 2021 17:30
Text
This advisory contains mitigations for an Improper Access Control vulnerability in Siemens TIA Administrator products.
Titel
Siemens SCALANCE W780 and W740
Veröffentlicht
9. Februar 2021 17:20
Text
This advisory contains mitigations for an Allocation of Resources Without Limits or Throttling vulnerability in Siemens SCALANCE W780 and W740 industrial wireless LAN products.
Titel
SSA-379803 V1.0: Vulnerabilities in RUGGEDCOM ROX II
Veröffentlicht
9. Februar 2021 01:00
Text
The latest update for ROX II contains multiple fixes for IPsec related vulnerabilities in Libreswan and NSS. Siemens has released updates for the affected products and recommends to update to the latest versions.
Titel
SSA-978220 V1.3 (Last Update: 2021-02-09): Denial-of-Service Vulnerability over SNMP in Multiple Industrial Products
Veröffentlicht
9. Februar 2021 01:00
Text
Several industrial products are affected by a vulnerability that could allow remote attackers to conduct a Denial-of-Service (DoS) attack by sending specially crafted packets to port 161/udp (SNMP). Siemens has released updates for several affected products and recommends to update to the new versions. Siemens is preparing further updates and ...
Titel
SSA-951513 V1.1 (Last Update: 2021-02-09): Clickjacking Vulnerability in SCALANCE X-300, X-200IRT, and X-200 Switch Families
Veröffentlicht
9. Februar 2021 01:00
Text
Several SCALANCE X switches contain a vulnerability that could allow an attacker to perform administrative actions if the victim is tricked into clicking on a website controlled by the attacker. The attack only works if the victim has an authenticated session on the administrative interface of the switch. Siemens has ...
Titel
SSA-886514 V1.1 (Last Update: 2021-02-09): Persistent XSS Vulnerabilities in the Web Interface of Climatix POL908 and POL909 Modules
Veröffentlicht
9. Februar 2021 01:00
Text
The Climatix BACnet/IP (POL908) and AWM (POL909) modules contain two persistent cross-site scripting (XSS) vulnerabilities in the web interface that could allow a remote attacker to execute arbitrary JavaScript code in the context of other users’ web sessions. Siemens has released an update for Climatix POL909 and recommends to update ...
Titel
SSA-841348 V1.5 (Last Update: 2021-02-09): Multiple Vulnerabilities in the UMC Stack
Veröffentlicht
9. Februar 2021 01:00
Text
The latest update for the below listed products fixes two security vulnerabilities that could allow an attacker to cause a partial Denial-of-Service on the UMC component of the affected devices under certain circumstances, and one vulnerability that could allow an attacker to locally escalate privileges from a user with administrative ...
Titel
SSA-646841 V1.2 (Last Update: 2021-02-09): Recoverable Password from Configuration Storage in SCALANCE X Switches
Veröffentlicht
9. Februar 2021 01:00
Text
A vulnerability exists in several SCALANCE X switches that could allow external entities to reconstruct passwords for users of the affected devices if an attacker is able to obtain a backup of the device configuration. Siemens has released updates for several affected products and recommends to update to the latest ...
Titel
SSA-622830 V1.1 (Last Update: 2021-02-09): Multiple File Parsing Vulnerabilities in JT2Go and Teamcenter Visualization before V13.1.0
Veröffentlicht
9. Februar 2021 01:00
Text
Siemens has released version V13.1.0 for JT2Go and Teamcenter Visualization to fix multiple vulnerabilities that could be triggered when the products read files in different file formats (JT, XML, CG4, CGM, PDF, RGB, SGI, TGA, PAR, ASM, PCX). If a user is tricked to opening of a malicious file with ...