February 2020
Title
SSA-113131 (Last Update: 2020-02-10): Denial-of-Service Vulnerabilities in SIMATIC S7-400 CPUs
Published
Feb. 10, 2020, 1 a.m.
Summary
Two vulnerabilities have been identified in the SIMATIC S7-400 CPU family that could allow an attacker to cause a Denial-of-Service condition. In order to exploit the vulnerability, an attacker must have access to the affected devices on port 102/tcp via Ethernet, PROFIBUS or Multi Point Interfaces (MPI). Siemens provides updates ...
Title
SSA-672373 (Last Update: 2020-02-10): Vulnerabilities in CP 1543-1
Published
Feb. 10, 2020, 1 a.m.
Summary
The latest firmware update for SIMATIC CP 1543-1 devices fixes two vulnerabilities. One of these vulnerabilities could allow authorized users to escalate their privileges on the CP.
Title
SSA-470231 (Last Update: 2020-02-10): TPM Vulnerability in SIMATIC IPCs
Published
Feb. 10, 2020, 1 a.m.
Summary
Several SIMATIC IPCs include a version of Infineon's Trusted Platform Module (TPM) firmware that mishandles RSA key generation. This makes it easier for attackers to conduct cryptographic attacks against the key material. Siemens has released updates for the affected Industrial PCs.
Title
SSA-623229 (Last Update: 2020-02-10): DROWN Vulnerability in Industrial Products
Published
Feb. 10, 2020, 1 a.m.
Summary
The disclosed attack called DROWN (Decrypting RSA with Obsolete and Weakened eNcryption), also known as CVE-2016-0800, could potentially allow the decryption of SSL/TLS sessions of some Siemens industrial products under certain conditions. Siemens has released firmware updates and solutions to resolve the vulnerability
Title
SSA-346262 (Last Update: 2020-02-10): Denial-of-Service in Industrial Products
Published
Feb. 10, 2020, 1 a.m.
Summary
Several industrial products are affected by a vulnerability that could allow remote attackers to conduct a Denial-of-Service (DoS) attack by sending specially crafted packets to port 161/udp (SNMP). Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates ...
Title
SSA-110922 (Last Update: 2020-02-10): Web Vulnerability in TIM 1531 IRC
Published
Feb. 10, 2020, 1 a.m.
Summary
The latest update for TIM 1531 IRC fixes a security vulnerability that could allow unauthorized remote attackers to perform administrative operations on the device. Siemens recommends updating as soon as possible.
Title
SSA-774850 (Last Update: 2020-02-10): Vulnerabilities in SIEMENS LOGO!8 devices
Published
Feb. 10, 2020, 1 a.m.
Summary
Two vulnerabilities have been identified in SIEMENS LOGO!8 devices. The Session ID on the integrated webserver of LOGO!8 devices is not invalidated upon logout. The second vulnerability could allow an attacker with network access to port 10005/tcp to cause a Denial-of-Service condition by sending specifically crafted packages to the service. ...
Title
SSA-234763 (Last Update: 2020-02-10): OpenSSL Vulnerabilities in Siemens Industrial Products
Published
Feb. 10, 2020, 1 a.m.
Summary
Vulnerabilities in OpenSSL (see https://www.openssl.org/news/secadv_20140605.txt) affect several Siemens industrial products. Siemens has released updates for all affected products.
Title
SSA-654382 (Last Update: 2020-02-10): Vulnerabilities in SIMATIC S7-1200 CPU Familiy
Published
Feb. 10, 2020, 1 a.m.
Summary
The latest product release of the SIMATIC S7-1200 CPU fixes several vulnerabilities. The most severe of these vulnerabilities could allow an attacker to take over an authenticated web session if the session token can be predicted. The attacker must have network access to the device to exploit this vulnerability. Further ...
Title
SSA-176087 (Last Update: 2020-02-10): Unauthenticated Access to Critical Services in SCALANCE X-200 Switch Family
Published
Feb. 10, 2020, 1 a.m.
Summary
A potential vulnerability was discovered in the web server authentication of SCALANCE X-200 and X-200IRT switches that might allow attackers to perform administrative operations over the network without authentication. This issue only applies to switches using older firmware versions and has been fixed from firmware V4.5.0 (non-IRT) and V5.1.0 (IRT) ...
January 2020
Title
SSA-181018 (Last Update: 2020-01-14): Heap Overflow Vulnerability in SCALANCE X switches, RUGGEDCOM Win, RFID 181-EIP, and SIMATIC RF182C
Published
Jan. 14, 2020, 1 a.m.
Summary
SCALANCE X switches, RUGGEDCOM Win, RFID 181-EIP, and SIMATIC RF182C are affected by a vulnerability that could allow an unprivileged attacker located in the same local network segment (OSI Layer 2) to gain system privileges by sending a specially crafted DHCP response to a client's DHCP request. Siemens has released ...
Title
SSA-632562 (Last Update: 2020-01-14): Vulnerabilities in SIPROTEC 5 Ethernet plug-in communication modules and devices
Published
Jan. 14, 2020, 1 a.m.
Summary
The SIPROTEC 5 Ethernet plug-in communication modules and devices are affected by multiple security vulnerabilities. These vulnerabilities could allow an attacker to leverage various attacks, e.g. to execute arbitrary code over the network. The underlying Wind River VxWorks network stack is affected by eleven vulnerabilities known as 'URGENT/11'. Of these, ...
Title
SSB-439005 (Last Update: 2020-01-14): Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP
Published
Jan. 14, 2020, 1 a.m.
Summary
Title
SSA-443566 (Last Update: 2020-01-14): Authentication Bypass in SCALANCE X Switches Families
Published
Jan. 14, 2020, 1 a.m.
Summary
Several SCALANCE X switches are affected by an Authentication Bypass vulnerability. The vulnerability allows an unauthenticated attacker to violate access-control rules. The vulnerability can be exploited by sending a GET request to a specific uniform resource locator on the web configuration interface of the device. The security vulnerability could be ...
Title
SSB-382508 (Last Update: 2020-01-14): ActiveX used in Industrial Products
Published
Jan. 14, 2020, 1 a.m.
Summary
Title
SSA-616199 (Last Update: 2020-01-14): BlueKeep Vulnerability Identified in RAPIDPoint® 500 Operating on Windows XP
Published
Jan. 14, 2020, 1 a.m.
Summary
Microsoft has released updates for several versions of Microsoft Windows, which fix a vulnerability in the Remote Desktop Service. The vulnerability could allow an unauthenticated remote attacker to execute arbitrary code on the target system if the system exposes the service to the network. RAPIDPoint® 500 systems operating on Windows ...
Title
SSA-307392 (Last Update: 2020-01-14): Denial-of-Service in OPC UA in Industrial Products
Published
Jan. 14, 2020, 1 a.m.
Summary
A vulnerability has been identified in the OPC UA server of several industrial products. The vulnerability could cause a Denial-of-Service condition on the service or the device. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates and ...
Title
SSA-557804 (Last Update: 2020-01-14): Mirror Port Isolation Vulnerability in SCALANCE X Switches
Published
Jan. 14, 2020, 1 a.m.
Summary
A vulnerability was identified in several SCALANCE X switches that could allow an attacker to feed information into a network via the mirror port with the monitor barrier feature enabled. The monitor barrier implementation in several SCALANCE X switches does allow traffic to be directed back into the mirroring network. ...
Title
SSA-480230 (Last Update: 2020-01-14): Denial-of-Service in Webserver of Industrial Products
Published
Jan. 14, 2020, 1 a.m.
Summary
A vulnerability in the affected devices could allow an unauthorized attacker with network access to the webserver of an affected device to perform a denial-of-service attack. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates and recommends ...
Title
SSA-242353 (Last Update: 2020-01-14): Access Control Vulnerability in SINAMICS PERFECT HARMONY GH180
Published
Jan. 14, 2020, 1 a.m.
Summary
A race condition in the restart behaviour of SINAMICS PERFECT HARMONY GH180 could allow an unauthorized attacker with physical access to the affected device to restart the HMI with disabled security controls, which could be used to launch further attacks against the affected device. Siemens recommends customers to apply a ...
Title
SSA-418979 (Last Update: 2020-01-14): Vulnerabilities in EN100 Ethernet Communication Module
Published
Jan. 14, 2020, 1 a.m.
Summary
The EN100 Ethernet communication modules are affected by security vulnerabilities which could allow an attacker to disclose information. Siemens has released updates for several affected products, is working on updates for the remaining affected products, and recommends specific countermeasures until fixes are available.
Title
SSA-349422 (Last Update: 2020-01-14): Denial-of-Service in Industrial Real-Time (IRT) Devices
Published
Jan. 14, 2020, 1 a.m.
Summary
A vulnerability in the affected products could allow an unauthorized attacker with network access to perform a denial-of-service attack resulting in loss of real-time synchronization. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates and recommends specific ...
Title
SSA-878278 (Last Update: 2020-01-14): Denial-of-Service Vulnerability in SIMATIC WinAC RTX (F) 2010
Published
Jan. 14, 2020, 1 a.m.
Summary
A vulnerability in SIMATIC WinAC RTX (F) 2010 controller software could allow an attacker to perform a denial-of-service attack if a large HTTP request is sent to the network port of the host where WinAC RTX is running. Siemens has released SIMATIC WinAC RTX (F) 2010 incl. SP3 Update 1 ...
Title
SSA-646841 (Last Update: 2020-01-14): Recoverable Password from Configuration Storage in SCALANCE X Switches
Published
Jan. 14, 2020, 1 a.m.
Summary
A vulnerability exists in several SCALANCE X switches that could allow external entities to reconstruct passwords for users of the affected devices if an attacker is able to obtain a backup of the device configuration. Siemens has released updates for some of the affected devices and is working on updates ...
Title
SSA-480829 (Last Update: 2020-01-14): Cross-Site-Scripting Vulnerabilities in SCALANCE X Switches
Published
Jan. 14, 2020, 1 a.m.
Summary
Two cross-site-scripting (XSS) vulnerabilities were found in the web server of several SCALANCE X switches. Siemens recommends updating the firmware to the newest version as soon as possible.

Last Updates

BOSCH PSIRT
10.06.2025
SIEMENS CERT
24.06.2025
US CERT
12.06.2025
US CERT (ICS)
01.07.2025

By Source

Archive

2025
2024
2023
2022
2021
2020
2019
2018
2017

Feeds