February 2020
Title
SSA-110922 (Last Update: 2020-02-10): Web Vulnerability in TIM 1531 IRC
Published
Feb. 10, 2020, 1 a.m.
Summary
The latest update for TIM 1531 IRC fixes a security vulnerability that could allow unauthorized remote attackers to perform administrative operations on the device. Siemens recommends updating as soon as possible.
Title
SSA-346262 (Last Update: 2020-02-10): Denial-of-Service in Industrial Products
Published
Feb. 10, 2020, 1 a.m.
Summary
Several industrial products are affected by a vulnerability that could allow remote attackers to conduct a Denial-of-Service (DoS) attack by sending specially crafted packets to port 161/udp (SNMP). Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates ...
Title
SSA-623229 (Last Update: 2020-02-10): DROWN Vulnerability in Industrial Products
Published
Feb. 10, 2020, 1 a.m.
Summary
The disclosed attack called DROWN (Decrypting RSA with Obsolete and Weakened eNcryption), also known as CVE-2016-0800, could potentially allow the decryption of SSL/TLS sessions of some Siemens industrial products under certain conditions. Siemens has released firmware updates and solutions to resolve the vulnerability
Title
SSA-470231 (Last Update: 2020-02-10): TPM Vulnerability in SIMATIC IPCs
Published
Feb. 10, 2020, 1 a.m.
Summary
Several SIMATIC IPCs include a version of Infineon's Trusted Platform Module (TPM) firmware that mishandles RSA key generation. This makes it easier for attackers to conduct cryptographic attacks against the key material. Siemens has released updates for the affected Industrial PCs.
Title
SSA-672373 (Last Update: 2020-02-10): Vulnerabilities in CP 1543-1
Published
Feb. 10, 2020, 1 a.m.
Summary
The latest firmware update for SIMATIC CP 1543-1 devices fixes two vulnerabilities. One of these vulnerabilities could allow authorized users to escalate their privileges on the CP.
Title
SSA-233109 (Last Update: 2020-02-10): Web Vulnerabilities in SIMATIC Panels
Published
Feb. 10, 2020, 1 a.m.
Summary
The latest update for SIMATIC Panel software and SIMATIC WinCC (TIA Portal) fixes two web vulnerabilities. The most severe is a vulnerability which could allow an attacker with network access to the integrated webserver to download arbitrary files. Siemens recommends to update to the newest version.
Title
SSA-179516 (Last Update: 2020-02-10): OpenSSL Vulnerability in Industrial Products
Published
Feb. 10, 2020, 1 a.m.
Summary
A vulnerability in OpenSSL affects several Siemens industrial products. Siemens has released updates for some affected products and is working on updates for others.
Title
SSA-487246 (Last Update: 2020-02-10): Vulnerabilities in SIMATIC HMI Devices
Published
Feb. 10, 2020, 1 a.m.
Summary
The latest updates for the affected products fix three vulnerabilities. The most severe of these vulnerabilities could allow an attacker to perform a Denial-of-Service attack against HMI panels under certain conditions.
Title
SSA-625789 (Last Update: 2020-02-10): Security Vulnerabilities in Siemens SIMATIC S7-1200 CPU
Published
Feb. 10, 2020, 1 a.m.
Summary
Security experts have examined the SIMATIC S7-1200 Programmable Logic Controller (PLC). This research has revealed some weaknesses in the SIMATIC S71200 CPU communication and authentication functions. Once the automation network is compromised it is possible to demonstrate the following weaknesses using a remote exploit: - Trigger CPU functions by record ...
Title
SSA-293562 (Last Update: 2020-02-10): Vulnerabilities in Industrial Products
Published
Feb. 10, 2020, 1 a.m.
Summary
Several industrial devices are affected by two vulnerabilities that could allow an attacker to cause a Denial-of-Service condition via PROFINET DCP network packets under certain circumstances. The precondition for this scenario is a direct layer 2 access to the affected products. PROFIBUS interfaces are not affected. Siemens has released updates ...
Title
SSA-874235 (Last Update: 2020-02-10): Intel Vulnerability in Siemens Industrial Products
Published
Feb. 10, 2020, 1 a.m.
Summary
Several Intel chipsets for Intel Core i5, Intel Core i7 and Intel XEON are susceptible to remote code execution vulnerability (CVE-2017-5689) [1]. As several Siemens Industrial Products use Intel technology, they are also affected. Siemens has released updates for the affected Industrial PCs. [1] Intel Security Advisory – INTEL-SA-00075:https://security-center.intel.com/advisory.aspx?intelid=INTEL-SA-00075&languageid=en-fr
Title
SSA-234763 (Last Update: 2020-02-10): OpenSSL Vulnerabilities in Siemens Industrial Products
Published
Feb. 10, 2020, 1 a.m.
Summary
Vulnerabilities in OpenSSL (see https://www.openssl.org/news/secadv_20140605.txt) affect several Siemens industrial products. Siemens has released updates for all affected products.
Title
SSA-774850 (Last Update: 2020-02-10): Vulnerabilities in SIEMENS LOGO!8 devices
Published
Feb. 10, 2020, 1 a.m.
Summary
Two vulnerabilities have been identified in SIEMENS LOGO!8 devices. The Session ID on the integrated webserver of LOGO!8 devices is not invalidated upon logout. The second vulnerability could allow an attacker with network access to port 10005/tcp to cause a Denial-of-Service condition by sending specifically crafted packages to the service. ...
Title
SSA-994726 (Last Update: 2020-02-10): GHOST Vulnerability in Siemens Industrial Products
Published
Feb. 10, 2020, 1 a.m.
Summary
The latest updates for the affected products fix the “GHOST” [1] vulnerability identified in glibc library (CVE-2015-0235). Incorrect parsing within the glibc library functions “gethostbyname()” and “gethostbyname2()” could cause a Denial-of-Service of the targeted system. [1] https://nvd.nist.gov/vuln/detail/CVE-2015-0235
Title
SSA-635659 (Last Update: 2020-02-10): Heartbleed Vulnerability in Siemens Industrial Products
Published
Feb. 10, 2020, 1 a.m.
Summary
The "Heartbleed" vulnerability in the OpenSSL cryptographic software library (CVE-2014-0160) affects several Siemens industrial products. Siemens has resolved the issue in all affected industrial products and provides updates which fix this vulnerability.
Title
SSA-542701 (Last Update: 2020-02-10): Vulnerabilities in SIEMENS LOGO!
Published
Feb. 10, 2020, 1 a.m.
Summary
Multiple vulnerabilities have been identified in SIEMENS LOGO!8 BM devices. The most severe vulnerability could lead to an attacker reading and modifying the device configuration if the attacker has access to port 10005/tcp.
January 2020
Title
SSA-557804 (Last Update: 2020-01-14): Mirror Port Isolation Vulnerability in SCALANCE X Switches
Published
Jan. 14, 2020, 1 a.m.
Summary
A vulnerability was identified in several SCALANCE X switches that could allow an attacker to feed information into a network via the mirror port with the monitor barrier feature enabled. The monitor barrier implementation in several SCALANCE X switches does allow traffic to be directed back into the mirroring network. ...
Title
SSA-418979 (Last Update: 2020-01-14): Vulnerabilities in EN100 Ethernet Communication Module
Published
Jan. 14, 2020, 1 a.m.
Summary
The EN100 Ethernet communication modules are affected by security vulnerabilities which could allow an attacker to disclose information. Siemens has released updates for several affected products, is working on updates for the remaining affected products, and recommends specific countermeasures until fixes are available.
Title
SSA-473245 (Last Update: 2020-01-14): Denial-of-Service Vulnerability in Profinet Devices
Published
Jan. 14, 2020, 1 a.m.
Summary
A vulnerability in affected devices could allow an attacker to perform a denial-of-service attack if a large amount of specially crafted UDP packets are sent to the device. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates ...
Title
SSA-632562 (Last Update: 2020-01-14): Vulnerabilities in SIPROTEC 5 Ethernet plug-in communication modules and devices
Published
Jan. 14, 2020, 1 a.m.
Summary
The SIPROTEC 5 Ethernet plug-in communication modules and devices are affected by multiple security vulnerabilities. These vulnerabilities could allow an attacker to leverage various attacks, e.g. to execute arbitrary code over the network. The underlying Wind River VxWorks network stack is affected by eleven vulnerabilities known as 'URGENT/11'. Of these, ...
Title
SSA-880233 (Last Update: 2020-01-14): Incorrect Session Validation Vulnerability in SINEMA Server
Published
Jan. 14, 2020, 1 a.m.
Summary
The latest update for SINEMA Server fixes a vulnerability that could allow authenticated users with a low-privileged account to perform firmware updates (as well as other administrative operations) on connected devices. Therefore, Siemens recommends to update the affected products.
Title
SSA-443566 (Last Update: 2020-01-14): Authentication Bypass in SCALANCE X Switches Families
Published
Jan. 14, 2020, 1 a.m.
Summary
Several SCALANCE X switches are affected by an Authentication Bypass vulnerability. The vulnerability allows an unauthenticated attacker to violate access-control rules. The vulnerability can be exploited by sending a GET request to a specific uniform resource locator on the web configuration interface of the device. The security vulnerability could be ...
Title
SSA-629512 (Last Update: 2020-01-14): Local Privilege Escalation Vulnerability in TIA Portal
Published
Jan. 14, 2020, 1 a.m.
Summary
The latest update for TIA Portal fixes a vulnerability that could allow a local attacker to execute arbitrary code with SYSTEM privileges. Siemens has released an update for TIA Portal V15, is working on updates for other versions of TIA Portal and recommends specific mitigations for vulnerable versions.
Title
SSA-878278 (Last Update: 2020-01-14): Denial-of-Service Vulnerability in SIMATIC WinAC RTX (F) 2010
Published
Jan. 14, 2020, 1 a.m.
Summary
A vulnerability in SIMATIC WinAC RTX (F) 2010 controller software could allow an attacker to perform a denial-of-service attack if a large HTTP request is sent to the network port of the host where WinAC RTX is running. Siemens has released SIMATIC WinAC RTX (F) 2010 incl. SP3 Update 1 ...
Title
SSA-349422 (Last Update: 2020-01-14): Denial-of-Service in Industrial Real-Time (IRT) Devices
Published
Jan. 14, 2020, 1 a.m.
Summary
A vulnerability in the affected products could allow an unauthorized attacker with network access to perform a denial-of-service attack resulting in loss of real-time synchronization. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates and recommends specific ...

Last Updates

BOSCH PSIRT
14.08.2025
SIEMENS CERT
26.08.2025
US CERT
25.08.2025
US CERT (ICS)
04.09.2025

By Source

Archive

2025
2024
2023
2022
2021
2020
2019
2018
2017

Feeds