An issue was discovered in the mymbCONNECT24 and mbCONNECT24 software in all versions through V2.9.0.



Critical vulnerabilities have been discovered in the utilized component log4net by Apache Software Foundation.
UPDATE A: Remediation: added fixed VisuNet Products 



The Weidmueller Remote I/O (IP20) fieldbus couplers (u-remote) are affected by several vulnerabilities of the third-party TCP/IP Niche stack. An attacker may use crafted IP packets to cause a denial of service or breach of integrity of the affected products. Weidmueller recommends restricting network access from the internet and also locally to reduce the attack vector to a manageable minimum.



The affected products contain a CODESYS Control runtime system in version V2. They are therefore affected by the
vulnerability described in CODESYS Advisory 2021-06. It provides a communication server for the communication with clients like the CODESYS Development System.

The 9400 servo inverters is only affected if the communication Path via the inserted EtherNet Module E94AYCEN on slot MXI1 or MXI2 is used. If the Module E94AYCEN is used, the following Versions are affected.

Product Identification: E94xSHxxx (Single Drive, High Line)
Product Identification: E94xMHxxx (Multi Drive, High Line)

Remark: If the product identification of your 9400 product does not fit to the above mentioned identification, please contact Lenze at Security.de@Lenze.com.

The Versions P (power supply module) and R (regenerative power supply module) are not affected. Furthermore, the Variant P (PLC) and the Variant S (StateLine) are not affected. The communication paths via the diagnostic interface X6, the system bus (CAN) X1 or the field buses (other than the named Ethernet module) that can be plugged into the module slots MXI1 or MXI2 are not affected.

The focus is therefore on 9400 servo inverters with the product-identification E94x{S/M}{H}... with a plugged in Ethernet module E94AYCEN... in module slot MXI1 or MXI2 and communication with the Engineer-Tools via exactly this channel.

In addition to the standard tool Engineer, there is also a special Version of the PLC Designer (Version 0.x). The communication path to the PLC Designer is not considered with the planned update and the vulnerabilities here remain even after the update. Here, the customer must provide a secure Environment, see Mitigation.



Promass 83 devices utilizing 499ES EtherNet/IP (ENIP) Stack by Real Time Automation (RTA) are vulnerable to a stack-based buffer overflow.

Update A, 2021-10-07:

  • added credits
  • changed title from "ENDRESS+HAUSER: Promass 83 with Ether/IP affected by DoS vulnerability" to "ENDRESS+HAUSER: Promass 83 with EtherNet/IP affected by a stack-based buffer overflow"

 