SIEMENS CERT
07/12/2022
Simcenter Femap and Parasolid are affected by an out of bounds read vulnerability that could be triggered when the application reads files in NEU format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the vulnerability to perform remote code execution …
SIEMENS CERT
07/12/2022
OpenSSL has published a security advisory [0] about a vulnerability in OpenSSL versions 1.1.1 < 1.1.1l and 1.0.2 < 1.0.2za that allows an attacker to cause a denial of service (DoS) or to disclose private memory content. Siemens has released updates for several affected products and recommends to update to …
SIEMENS CERT
07/12/2022
A vulnerability has been identified in the OPC Foundation Local Discovery Server (LDS) [0] of several industrial products. The vulnerability could cause a denial of service condition on the service or the device. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens …
SIEMENS CERT
07/12/2022
Siemens has released a new version for Teamcenter Visualization and JT2Go that fixes an out of bounds write vulnerability in APDFL library from Datalogics. If a user is tricked to open a malicious PDF file with the affected products, this could lead the application to crash or potentially lead to …
SIEMENS CERT
07/12/2022
Siemens PADS Standard/Plus Viewer is affected by multiple memory corruption vulnerabilities that could be triggered when the application reads files in PCB format. If a user is tricked to open a malicious file with the affected application, an attacker could leverage the vulnerability to perform remote code execution in the …
SIEMENS CERT
07/12/2022
A vulnerability in the openSSL component (CVE-2022-0778, [0]) could allow an attacker to create a denial of service condition by providing specially crafted elliptic curve certificates to products that use a vulnerable version of openSSL. Siemens has released updates for several affected products and recommends to update to the latest …
SIEMENS CERT
07/12/2022
In conjunction with the installation of the affected products listed in the table below, a vulnerability in TIA Administrator occurs that could allow an unauthenticated attacker to perform a denial of service attack. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
07/12/2022
Intel has published information on vulnerabilities in Intel products in November 2020. This advisory lists the Siemens IPC related products, that are affected by these vulnerabilities. In this advisory we take a representative CVE from each advisory: “Intel CSME, SPS, TXE, AMT and DAL Advisory” Intel-SA-00391 is represented by CVE-2020-8745 …