SIEMENS CERT
04/11/2023
The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, contains a vulnerability that could allow an attacker to cause a denial of service condition on affected industrial products. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further …
SIEMENS CERT
04/11/2023
Multiple vulnerabilities affect various third-party components of the RUGGEDCOM Operating System (ROS). If exploited, an attacker could cause a denial-of-service, act as a man-in-the-middle or retrieval of sensitive information or gain privileged functions. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
04/11/2023
The openSSL component, versions 3.0.0 through 3.0.6, contains two buffer overflow vulnerabilities (CVE-2022-3602, CVE-2022-3786) in the X.509 certificate verification [0]. They could allow an attacker to create a denial of service condition or execute arbitrary code on a vulnerable TLS server (if the server requests client certificate authentication), or on …
SIEMENS CERT
04/11/2023
RUGGEDCOM ROS-based V4 devices are vulnerable to a denial of service attack (Slowloris). By sending partial HTTP requests nonstop, with none completed, the affected web servers will be waiting for the completion of each request, occupying all available HTTP connections. The web server recovers by itself once the attack ends. …
SIEMENS CERT
04/11/2023
Polarion ALM contains a misconfiguration in its default Apache HTTP Server configuration that could allow an attacker to perform host header injection attacks. Siemens has released an update for Polarion ALM and recommends to update to the latest version.
SIEMENS CERT
04/11/2023
A Denial-of-Service vulnerability was found in SIMATIC PCS 7, SIMATIC WinCC and SIMATIC NET PC software when encrypted communication is enabled. The vulnerability could allow an attacker with network access to cause a Denial-of-Service condition under certain circumstances (versions prior to SIMATIC WinCC V7.3 or SIMATIC PCS 7 V8.1 are …
SIEMENS CERT
04/11/2023
Several SCALANCE X switches contain multiple vulnerabilities. An unauthenticated attacker could reboot, cause denial-of-service conditions and potentially impact the system by other means through heap and buffer overflow vulnerabilities. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates …
SIEMENS CERT
04/11/2023
A vulnerability has been identified in the OPC Foundation Local Discovery Server (LDS) [0] of several industrial products. The vulnerability could cause a denial of service condition on the service or the device. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens …