Bulletins

SIEMENS CERT
10/12/2021
The latest update for SIPROTEC 5 relays fixes two vulnerabilities that could allow a remote attacker to cause a denial-of-service or potentially trigger a remote code execution under certain circumstances. Siemens has released an update for SIPROTEC 5 relays and recommends to update to the latest version.
SIEMENS CERT
10/12/2021
Twelve vulnerabilities in the implementation of frame aggregation and fragmentation of the 802.11 standard, under the name of FragAttacks, have been published. Successful exploitation of these vulnerabilities could allow an attacker within Wi-Fi range to forge encrypted frames, which could result in sensitive data disclosure and possibly traffic manipulation. The …
SIEMENS CERT
10/12/2021
The Scalance W1750D device contains multiple vulnerabilities that could allow an attacker to inject commands or trigger buffer overflows. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
10/12/2021
A vulnerability was identified in several SCALANCE X switches that could allow an attacker to feed information into a network via the mirror port with the monitor barrier feature enabled. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures …
SIEMENS CERT
10/12/2021
The Scalance W1750D device contains multiple vulnerabilities that could allow an attacker to inject commands or trigger buffer overflows. Siemens is preparing updates and recommends countermeasures for products where updates are not, or not yet available.
SIEMENS CERT
10/12/2021
A vulnerability in affected devices could allow an attacker to perform a denial-of-service attack if a large amount of Profinet Discovery and Configuration Protocol (DCP) reset packets is sent to the affected devices. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens …
SIEMENS CERT
10/12/2021
The latest update for SINEC NMS fixes multiple vulnerabilities. The most severe could allow an authenticated remote attacker to execute arbitrary code on the system, with system privileges, under certain conditions. Siemens has released an update for SINEC NMS and recommends to update to the latest version.
SIEMENS CERT
10/12/2021
The latest update for RUGGEDCOM ROX devices fixes a vulnerability that could allow an unauthenticated attacker to cause a permanent Denial-of-Service condition under certain conditions. Siemens has released updates for the affected products and recommends to update to the latest versions.