Bulletins

SIEMENS CERT
02/09/2021
Several SCALANCE X switches contain vulnerabilities in the web server of the affected devices. An unauthenticated attacker could reboot, cause denial-of-service conditions and potentially impact the system by other means through heap and buffer overflow vulnerabilities. Siemens has released updates for several affected products and recommends to update to the …
SIEMENS CERT
02/09/2021
The products listed below contain a vulnerability that could allow remote attackers to affect the availability of the devices under certain conditions. The underlying TCP stack can be forced to make very computation expensive calls for every incoming packet which can lead to a Denial-of-Service. Siemens has released an update …
SIEMENS CERT
02/09/2021
There exists a directory traversal vulnerability which allows arbitrary file upload to an affected system. This type of vulnerability is also known as ‘Zip-Slip’. An authenticated attacker could exploit this vulnerability to gain arbitrary code execution by uploading a new or modifying an existing file to an affected system. Siemens …
SIEMENS CERT
02/09/2021
Some versions of Mentor Nucleus ReadyStart and Nucleus NET use Initial Sequence Numbers for TCP- Sessions that are predictable. Siemens has released updates for the affected products and recommends to update to the latest version(s).
SIEMENS CERT
02/09/2021
CISA and WIBU Systems disclosed six vulnerabilities in different versions of CodeMeter Runtime, a product provided by WIBU Systems and used in several Siemens and Siemens Energy products for license management. The vulnerabilities are described in the section “Vulnerability Classification” below and got assigned the CVE IDs CVE-2020-14509, CVE-2020-14513, CVE-2020-14515, …
SIEMENS CERT
02/09/2021
The latest update for ROX II contains multiple fixes for IPsec related vulnerabilities in Libreswan and NSS. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
02/09/2021
The latest update for TIA Administrator, installed together with TIA Portal and PCS neo, fixes a privilege escalation vulnerability that could allow local users to escalate privileges and execute code as local SYSTEM user. Siemens has released an update for TIA Portal and recommends that customers update to the latest …
SIEMENS CERT
02/09/2021
A vertical privilege escalation vulnerability exists in DIGSI 4. Siemens has released an update for DIGSI 4 and recommends to update to the latest version.