Bulletins

SIEMENS CERT
07/14/2026
Opcenter X before V2604 contain an authentication bypass vulnerability that could allow an attacker to gain full unauthorized access to the application. Siemens has released a new version for Opcenter X and recommends to update to the latest version.
SIEMENS CERT
07/14/2026
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and …
SIEMENS CERT
07/14/2026
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version V3.1.6 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.
SIEMENS CERT
07/14/2026
Multiple industrial devices contain a vulnerability that could allow an attacker to cause a denial of service condition. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are …
SIEMENS CERT
07/14/2026
OpenSSL has published a stack based buffer overflow vulnerability that allows a remote attacker to cause a denial of service (DoS) or potentially allow for remote code execution. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix …
SIEMENS CERT
07/14/2026
Simcenter STAR-CCM+ contains an information disclosure vulnerability when using the Power-on-Demand public license server. An attacker could access a system’s host, user, and display name. Siemens has updated the public Power-on-Demand public license server.
SIEMENS CERT
07/14/2026
CADRA is affected by multiple zlib and Foxit vulnerabilities. Siemens has released a new version for CADRA and recommends to update to the latest version. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.
CISA (ALL)
07/13/2026

Russian Government-Sponsored Activity Targets Poorly Configured and Vulnerable Devices Across Critical Sectors

Executive summary

Russian Federal Security Service (FSB) Center 16 cyber actors continue to exploit poorly configured and vulnerable networking devices worldwide, opportunistically compromising multiple critical infrastructure sector networks. This joint Cybersecurity Advisory (CSA) builds on FBI’s …