CISA (ICS)
05/12/2026
Summary Successful exploitation of this vulnerability could allow an attacker to elevate privileges from user to system, which may then enable the attacker to cause a temporary denial of service, open files, or delete files. The following versions of Fuji Electric Tellus are affected: Tellus 5.0.2 CVSS Vendor Equipment Vulnerabilities …
CISA (ICS)
05/12/2026
Summary ABB became aware of multiple internally discovered vulnerabilities in the WebPro SNMP card PowerValue for the product versions listed as affected in the advisory. Depending upon the vulnerability, an attacker with access to local network who successfully exploited this vulnerability could have - Unauthorized access - Insufficient Session Expiration …
CISA (ICS)
05/12/2026
Summary ABB became aware of severe vulnerability in the products versions listed as affected in the advisory. An update is available that resolves these vulnerabilities. An attacker who successfully exploited these vulnerabilities could bypass the user management and read visualization files (CVE-2025-2595), read and write certificates and keys (CVE-2025-41659) or …
CISA (ICS)
05/12/2026
Summary ABB became aware of severe vulnerability in the products versions listed as affected in the advisory. The Windows gateway is accessible remotely by default. Unauthenticated attackers can therefore search for PLCs, but the user management of the PLCs prevents the actual access to the PLCs – unless it is …
SIEMENS CERT
05/12/2026
Siemens Industrial Edge Devices contain an authorization bypass vulnerability that could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Siemens has released new versions for the affected products and recommends to update to the latest versions.
SIEMENS CERT
05/12/2026
Ruggedcom Rox contains an improper access control vulnerability that could allow an authenticated remote attacker to read arbitrary files with root privileges from the underlying operating system’s filesystem. Siemens has released new versions for the affected products and recommends to update to the latest versions.
SIEMENS CERT
05/12/2026
Siemens gPROMS Web Applications Publisher (gWAP) is affected by a remote code execution vulnerability introduced through a third-party component, namely the Axios HTTP client library. The vulnerability stems from a specific “Gadget” attack chain that allows prototype pollution in other third-party libraries, potentially allowing an attacker to execute arbitrary code. …
SIEMENS CERT
05/12/2026
Opcenter RDnL is affected by missing authentication in critical function in ‘ActiveMQ Artemis’. An unauthenticated attacker within the adjacent network could use the Core protocol to force a target broker to establish an outbound Core federation connection to an attacker-controlled rogue broker. This could potentially result in availability impacts or …