May 2024
Title
SSA-923361 V1.0: MODEL File Parsing Vulnerability in Tecnomatix Plant Simulation before V2302.0011
Published
May 14, 2024, 2 a.m.
Summary
Tecnomatix Plant Simulation contains an out of bounds write vulnerability that could be triggered when the application reads MODEL files. If a user is tricked to open a malicious file using the affected application, this could lead to a crash, and potentially also to arbitrary code execution on the target ...
Title
SSA-661579 V1.0: Multiple File Parsing Vulnerabilities in Teamcenter Visualization and JT2Go
Published
May 14, 2024, 2 a.m.
Summary
Teamcenter Visualization and JT2Go are affected by multiple file parsing vulnerabilities that could be triggered when the application reads malicious CGM or XML files. If a user is tricked to open a malicious file with the affected products, this could lead the application to crash or potentially lead to arbitrary ...
Title
SSA-916916 V1.0: Security Vulnerabilities Fixed in RUGGEDCOM CROSSBOW V5.5
Published
May 14, 2024, 2 a.m.
Summary
The RUGGEDCOM CROSSBOW server application before V5.5 contains multiple vulnerabilities that could allow an attacker to execute arbitrary database queries via SQL injection attacks, or upload of arbitrary files to the application’s file system. The majority of the reported vulnerabilities might have a high impact in the availability of the ...
Title
SSA-046364 V1.0: X_T File Parsing Vulnerabilities in Parasolid
Published
May 14, 2024, 2 a.m.
Summary
Parasolid is affected by out of bounds read and null pointer dereference vulnerabilities that could be triggered when the application reads files in X_T format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the out of bounds read vulnerabilities to ...
Title
SSA-953710 V1.0: Vulnerabilities in the Network Communication Stack in Desigo Fire Safety UL and Cerberus PRO UL Fire Protection Systems
Published
May 14, 2024, 2 a.m.
Summary
Several products used in Desigo Fire Safety UL and Cerberus PRO UL Fire Protection Systems contain buffer overflow vulnerabilities in the network communication stack. Successful exploitation of the vulnerabilities could allow an unauthenticated attacker, who gained access to the fire protection system network, to execute arbitrary code on the affected ...
Title
SSA-148641 V1.2 (Last Update: 2024-05-14): XPath Constraint Vulnerability in Mendix Runtime
Published
May 14, 2024, 2 a.m.
Summary
A XPath Constraint vulnerability in the Mendix Runtime was discovered, that can affect the running applications. The vulnerability could allow a malicious user to deduce contents of inaccessible attributes and modify sensitive data. Siemens has released new versions for the affected products and recommends to update to the latest versions.
Title
SSA-093430 V1.0: Multiple Vulnerabilities in SIMATIC RTLS Locating Manager before V3.0
Published
May 14, 2024, 2 a.m.
Summary
Siemens has released a new version for SIMATIC RTLS Locating Manager and recommends to update to the latest version.
Title
SSA-935500 V1.1 (Last Update: 2024-05-14): Denial of Service Vulnerability in FTP Server of Nucleus RTOS based APOGEE, TALON and Desigo PXC/PXM Products
Published
May 14, 2024, 2 a.m.
Summary
A denial of service vulnerability has been identified in the Nucleus RTOS (real-time operating system) and reported in the Siemens Security Advisory SSA-313313: https://cert-portal.siemens.com/productcert/html/ssa-313313.html. The products listed below use affected versions of the Nucleus software and inherently contain the vulnerability. Siemens has released new versions for several affected products and ...
Title
SSA-976324 V1.0: Multiple IGS File Parsing Vulnerabilities in PS/IGES Parasolid Translator Component before V27.1.215
Published
May 14, 2024, 2 a.m.
Summary
PS/IGES Parasolid Translator Component contains multiple file parsing vulnerabilities that could be triggered when the application reads files in IGS file formats. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary ...
Title
SSA-592380 V1.2 (Last Update: 2024-05-14): Denial of Service Vulnerability in SIMATIC S7-1500 CPUs and related products
Published
May 14, 2024, 2 a.m.
Summary
A vulnerability has been identified in the SIMATIC S7-1500 CPU family and related products that could allow an attacker to cause a denial of service condition. In order to exploit the vulnerability, an attacker must have access to the affected devices on port 102/tcp. Siemens has released updates for several ...
Title
SSA-258494 V1.0: Stack Overflow Vulnerability in Simcenter Nastran before 2406.90
Published
May 14, 2024, 2 a.m.
Summary
Simcenter Nastran is affected by a stack overflow vulnerability that could be triggered when an application binary reads arbitrary string as a file argument. If a user is tricked to run one of the impacted application binary with a malicious string, an attacker could leverage the vulnerability to perform remote ...
Title
SSA-968170 V1.3 (Last Update: 2024-05-14): Remote Code Execution Vulnerability in SIMATIC STEP 7 V5.x and Derived Products
Published
May 14, 2024, 2 a.m.
Summary
SIMATIC STEP 7 and PCS 7 contain a database management system that could allow remote users to use embedded functions of the database (local or in a network share) that have impact on the server. An attacker with network access to the server network could leverage these embedded functions to ...
Title
SSA-925850 V1.0: Improper Access Control in Polarion ALM
Published
May 14, 2024, 2 a.m.
Summary
The Apache Lucene based query engine in Polarion ALM lacks proper access controls. This could allow an authenticated user to query items beyond the user’s allowed projects. Siemens has released a new version for Polarion ALM and recommends to update to the latest version.
Title
SSA-240541 V1.3 (Last Update: 2024-05-14): WIBU Systems CodeMeter Heap Buffer Overflow Vulnerability in Industrial Products
Published
May 14, 2024, 2 a.m.
Summary
WIBU Systems published information about a heap buffer overflow vulnerability and associated fix releases of CodeMeter Runtime, a product provided by WIBU Systems and used in several Siemens industrial products for license management. The vulnerability is described in the section ‘Vulnerability Classification’ below and got assigned the CVE ID CVE-2023-3935. ...
Title
SSA-593272 V2.1 (Last Update: 2024-05-14): SegmentSmack in Interniche IP-Stack based Industrial Devices
Published
May 14, 2024, 2 a.m.
Summary
A vulnerability exists in affected products that could allow remote attackers to affect the availability of the devices under certain conditions. The underlying TCP stack can be forced to make very computation expensive calls for every incoming packet which can lead to a Denial-of-Service. Siemens has released new versions for ...
Title
SSA-962515 V1.0: Out of Bounds Read Vulnerability in Industrial Products
Published
May 14, 2024, 2 a.m.
Summary
Several industrial products contain an out of bounds read vulnerability that could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel, leading to denial of service condition. Siemens has released new versions for several affected products and recommends to update to the ...
Title
SSA-225840 V1.1 (Last Update: 2024-05-14): Vulnerabilities in the Network Communication Stack in Sinteso EN and Cerberus PRO EN Fire Protection Systems
Published
May 14, 2024, 2 a.m.
Summary
Several products used in Sinteso EN and Cerberus PRO EN Fire Protection Systems contain buffer overflow vulnerabilities in the network communication stack. Successful exploitation of the vulnerabilities could allow an unauthenticated attacker, who gained access to the fire protection system network, to execute arbitrary code on the affected products (CVE-2024-22039) ...
April 2024
Title
SSA-750274 V1.0: Impact of CVE-2024-3400 on RUGGEDCOM APE1808 devices configured with Palo Alto Networks Virtual NGFW
Published
April 19, 2024, 2 a.m.
Summary
Palo Alto Networks has published [1] information on CVE-2024-3400 in PAN-OS. This advisory addresses Siemens Industrial products affected by this vulnerability. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available. Customers are advised to consult and implement the workarounds provided in ...
Title
SSA-203374 V1.2 (Last Update: 2024-04-09): Multiple OpenSSL Vulnerabilities in SCALANCE W1750D Devices
Published
April 9, 2024, 2 a.m.
Summary
The SCALANCE W1750D device contains multiple vulnerabilities in the integrated OpenSSL component that could allow an attacker to read memory contents, decrypt RSA-encrypted messages or create a denial of service condition. Siemens has released new versions for the affected products and recommends to update to the latest versions.
Title
SSA-128433 V1.0: Multiple Vulnerabilities in SINEC NMS before V2.0 SP2
Published
April 9, 2024, 2 a.m.
Summary
SINEC NMS before V2.0 SP2 is affected by multiple vulnerabilities. Siemens has released an update for SINEC NMS and recommends to update to the latest version.
Title
SSA-265688 V1.0: Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.1
Published
April 9, 2024, 2 a.m.
Summary
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.1. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.
Title
SSA-398330 V1.4 (Last Update: 2024-04-09): Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP V3.1
Published
April 9, 2024, 2 a.m.
Summary
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version V3.1 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not ...
Title
SSA-222019 V1.0: X_T File Parsing Vulnerabilities in Parasolid
Published
April 9, 2024, 2 a.m.
Summary
Parasolid is affected by out of bounds read, stack exhaustion and null pointer dereference vulnerabilities that could be triggered when the application reads files in X_T format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the vulnerability to perform remote ...
Title
SSA-691715 V1.4 (Last Update: 2024-04-09): Vulnerability in OPC Foundation Local Discovery Server Affecting Siemens Products
Published
April 9, 2024, 2 a.m.
Summary
A vulnerability was identified in OPC Foundation Local Discovery Server which also affects Siemens products that could allow an attacker to escalate privileges under certain circumstances. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and ...
Title
SSA-556635 V1.0: Multiple Vulnerabilities in Telecontrol Server Basic before V3.1.2.0
Published
April 9, 2024, 2 a.m.
Summary
Siemens has released a new version for Telecontrol Server Basic that fixes multiple vulnerabilities.

Last Updates

BOSCH PSIRT
15.01.2025
SIEMENS CERT
13.03.2025
US CERT
11.03.2025
US CERT (ICS)
13.03.2025

By Source

Archive

2025
2024
2023
2022
2021
2020
2019
2018
2017

Feeds