Bulletins

SIEMENS CERT
11/17/2025
PS/IGES Parasolid Translator Component contains an out of bounds read that could be triggered when the application reads files in IGS file formats. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to …
SIEMENS CERT
11/17/2025
Mendix RichText editor contain a cross-site scripting vulnerability. Siemens has released a new version for Mendix RichText and recommends to update to the latest version.
SIEMENS CERT
11/11/2025
The installers used to install several Siemens products are affected by a DLL hijacking vulnerability. This could allow an attacker to execute arbitrary code when a legitimate user installs an application that uses the affected installer component. This vulnerability poses a risk only during setup and installation phase of the …
SIEMENS CERT
11/11/2025
LOGO! 8 BM (incl. SIPLUS variants) contains multiple vulnerabilities. These could allow an attacker to execute code remotely, put the device into a denial of service state, or change the behavior of the device. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or …
SIEMENS CERT
11/11/2025
Multiple vulnerabilities has been identified in Siemens SIMATIC IPCs, SIMATIC Tablet PCs, and SIMATIC Field PGs that can allow an authenticated attacker to alter the secure boot and password configurations. Siemens has released new versions of BIOS for several affected products and recommends to update to the latest versions. Siemens …
SIEMENS CERT
11/11/2025
The web interface of RUGGEDCOM ROX II devices contain multiple Client-Side Enforcement of Server-Side Security vulnerabilities that could allow an attacker with a legitimate, highly privileged account on the web interface to get privileged code execution in the underlying OS of the affected products. Siemens has released new versions for …
SIEMENS CERT
11/11/2025
The web server of SICAM P850 and SICAM P855 devices, versions before V3.11, contains a Cross Site Request Forgery (CSRF) vulnerability and is missing cookie protection flags. This could allow an attacker to perform arbitrary actions on the device on behalf of a legitimate user, or impersonate that user. Siemens …
SIEMENS CERT
11/11/2025
Spectrum Power 4 before v4.70 SP12 Security Patch 2 contains multiple vulnerabilities that could allow an attacker to remotely execute code as application administrator or locally execute code as operating system administrator. Siemens has released a new version for Spectrum Power 4 and recommends to update to the latest version.