October 2024
Title
SSA-999588 V1.6 (Last Update: 2024-10-08): Multiple Vulnerabilities in User Management Component (UMC) Before V2.11.2
Published
Oct. 8, 2024, 2 a.m.
Summary
Siemens User Management Component (UMC) before V2.11.2 is affected by multiple vulnerabilities where the most severe could lead to a restart of the UMC server. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends ...
Title
SSA-962515 V1.3 (Last Update: 2024-10-08): Out of Bounds Read Vulnerability in Industrial Products
Published
Oct. 8, 2024, 2 a.m.
Summary
Several industrial products contain an out of bounds read vulnerability that could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel, leading to denial of service condition. Siemens has released new versions for several affected products and recommends to update to the ...
Title
SSA-844582 V1.2 (Last Update: 2024-10-08): Electromagnetic Fault Injection in LOGO! V8.3 BM Devices Results in Broken LOGO! V8.3 Product CA
Published
Oct. 8, 2024, 2 a.m.
Summary
LOGO! V8.3 BM (incl. SIPLUS variants) devices contain a vulnerability that could allow an electromagnetic fault injection. This could allow an attacker to dump and debug the firmware, including the manipulation of memory. Further actions could allow to inject public keys of custom created key pairs which are then signed ...
Title
SSA-620288 V1.2 (Last Update: 2024-10-08): Multiple Vulnerabilities (NUCLEUS:13) in Capital Embedded AR Classic
Published
Oct. 8, 2024, 2 a.m.
Summary
Multiple vulnerabilities (also known as “NUCLEUS:13”) have be identified in the Nucleus RTOS (real-time operating system) and reported in the Siemens Security Advisory SSA-044112: https://cert-portal.siemens.com/productcert/html/ssa-044112.html. Capital Embedded AR Classic uses an affected version of the Nucleus software and inherently contains several of these vulnerabilities. Siemens has released a new version ...
Title
SSA-039007 V1.1 (Last Update: 2024-10-08): Heap-based Buffer Overflow Vulnerability in User Management Component (UMC)
Published
Oct. 8, 2024, 2 a.m.
Summary
Siemens User Management Component (UMC) is affected by a heap-based buffer overflow vulnerability which could allow an unauthenticated remote attacker arbitrary code execution. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures for ...
Title
SSA-254396 V1.0: Vulnerability in Nozomi Guardian/CMC Before 24.3.1 on RUGGEDCOM APE1808 Devices
Published
Oct. 8, 2024, 2 a.m.
Summary
Nozomi Networks has published information on vulnerabilities in Nozomi Guardian/CMC before 24.2.0. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions.
Title
SSA-148641 V1.3 (Last Update: 2024-10-08): XPath Constraint Vulnerability in Mendix Runtime
Published
Oct. 8, 2024, 2 a.m.
Summary
A XPath Constraint vulnerability in the Mendix Runtime was discovered, that can affect the running applications. The vulnerability could allow a malicious user to deduce contents of inaccessible attributes and modify sensitive data. Siemens has released new versions for the affected products and recommends to update to the latest versions.
Title
SSA-321292 V1.6 (Last Update: 2024-10-08): Denial of Service in the OPC Foundation Local Discovery Server (LDS) in Industrial Products
Published
Oct. 8, 2024, 2 a.m.
Summary
A vulnerability has been identified in the OPC Foundation Local Discovery Server (LDS) [0] of several industrial products. The vulnerability could cause a denial of service condition on the service or the device. Siemens has released new versions for several affected products and recommends to update to the latest versions. ...
Title
SSA-097435 V1.2 (Last Update: 2024-10-08): Usernames Disclosure Vulnerability in Mendix Runtime
Published
Oct. 8, 2024, 2 a.m.
Summary
Mendix Runtime contains an observable response discrepancy vulnerability when validating usernames during authentication. This could allow unauthenticated remote attackers to distinguish between valid and invalid usernames. Siemens has released new versions for the affected products and recommends to update to the latest versions.
Title
SSA-054046 V1.0: Unauthenticated Information Disclosure in Web Server of SIMATIC S7-1500 CPUs
Published
Oct. 8, 2024, 2 a.m.
Summary
Several SIMATIC S7-1500 CPU versions are affected by an authentication bypass vulnerability that could allow an unauthenticated remote attacker to gain knowledge about actual and configured maximum cycle times and communication load of the CPU. Siemens has released new versions for several affected products and recommends to update to the ...
Title
SSA-340240 V1.0: Denial of Service Vulnerability in Sentron Powercenter 1000 with 3RV2921-5M accessory
Published
Oct. 8, 2024, 2 a.m.
Summary
A vulnerability in Sentron Powercenter 1000 with 3RV2921-5M accessory could allow an attacker to cause a denial of service condition. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.
Title
SSA-364175 V1.2 (Last Update: 2024-10-08): Multiple Vulnerabilities in Palo Alto Networks Virtual NGFW on RUGGEDCOM APE1808 Devices Before V11.1.4-h1
Published
Oct. 8, 2024, 2 a.m.
Summary
Palo Alto Networks has published [1] information on vulnerabilities in PAN-OS. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available. Customers are advised to consult and implement the workarounds ...
Title
SSA-426509 V1.0: Multiple Local Code Execution Vulnerabilities in Questa and ModelSim Before V2024.3
Published
Oct. 8, 2024, 2 a.m.
Summary
Questa and ModelSim (incl. OEM Editions) are affected by multiple vulnerabilities that could allow a local attacker to inject arbitrary code and escalate privileges. Siemens has released new versions for the affected products and recommends to update to the latest versions.
Title
SSA-398330 V1.9 (Last Update: 2024-10-08): Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP V3.1
Published
Oct. 8, 2024, 2 a.m.
Summary
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version V3.1 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not ...
Title
SSA-583523 V1.0: Multiple WRL File Parsing Vulnerabilities in Tecnomatix Plant Simulation
Published
Oct. 8, 2024, 2 a.m.
Summary
Siemens Tecnomatix Plant Simulation contains multiple file parsing vulnerabilities that could be triggered when the application reads files in WRL format. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code ...
Title
SSA-540493 V1.0: Kiosk Mode Escape Vulnerability in HiMed Cockpit Devices Before V11.6.2
Published
Oct. 8, 2024, 2 a.m.
Summary
HiMed Cockpit devices before V11.6.2 contain a Kiosk Mode Escape vulnerability that could allow an attacker to escape the restricted environment and gain access to the underlying operating system. Siemens has released a new version for the HiMed Cockpit devices and recommends to update to the latest version.
Title
SSA-455250 V1.4 (Last Update: 2024-10-08): Multiple Vulnerabilities in Palo Alto Networks Virtual NGFW on RUGGEDCOM APE1808 Devices Before V11.1.2-h3
Published
Oct. 8, 2024, 2 a.m.
Summary
Palo Alto Networks has published [1] information on vulnerabilities in PAN-OS. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens has released a new version of Palo Alto Networks Virtual NGFW for RUGGEDCOM APE1808 and recommends to update to the latest version. Customers are advised to ...
Title
SSA-368868 V1.0: Multiple Vulnerabilities in WibuKey for Windows
Published
Oct. 8, 2024, 2 a.m.
Summary
Several Siemens products (optionally) offer the use of WibuKey Dongles [1] for licensing. According to a recent publication by WIBU Systems (WIBU-94453 at [2]), the Windows device driver for these Dongles contains vulnerabilities as listed below. [1] https://www.wibu.com/products/wibukey.html [2] https://www.wibu.com/support/security-advisories.html WIBU Systems has released a new version for WibuKey for ...
Title
SSA-430425 V1.0: Multiple Vulnerabilities in SINEC Security Monitor before V4.9.0
Published
Oct. 8, 2024, 2 a.m.
Summary
SINEC Security Monitor before V4.9.0 contains multiple vulnerabilities. Siemens has released a new version for Siemens SINEC Security Monitor and recommends to update to the latest version.
Title
SSA-366067 V1.1 (Last Update: 2024-10-08): Multiple Vulnerabilities in Fortigate NGFW Before V7.4.1 on RUGGEDCOM APE1808 Devices
Published
Oct. 8, 2024, 2 a.m.
Summary
Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available. Siemens recommends to consult and implement the workarounds provided in Fortinet’s upstream security notifications.
September 2024
Title
SSA-097435 V1.1 (Last Update: 2024-09-12): Usernames Disclosure Vulnerability in Mendix Runtime
Published
Sept. 12, 2024, 2 a.m.
Summary
Mendix Runtime contains an observable response discrepancy vulnerability when validating usernames during authentication. This could allow unauthenticated remote attackers to distinguish between valid and invalid usernames. Siemens has released new versions for the affected products and recommends to update to the latest versions.
Title
SSA-792319 V1.1 (Last Update: 2024-09-10): Missing Read Out Protection in SENTRON 7KM PAC3x20 Devices
Published
Sept. 10, 2024, 2 a.m.
Summary
The read out protection of the internal flash of affected devices was not properly set at the end of the manufacturing process. An attacker with physical access to the device could read out the data. Siemens has released new versions for the affected products and recommends to update to the ...
Title
SSA-869574 V1.0: Multiple Vulnerabilities in SINEMA Remote Connect Server Before V3.2 SP2
Published
Sept. 10, 2024, 2 a.m.
Summary
SINEMA Remote Connect Server before V3.2 SP2 is affected by multiple vulnerabilities. Siemens has released a new version for SINEMA Remote Connect Client and recommends to update to the latest version.
Title
SSA-844582 V1.1 (Last Update: 2024-09-10): Electromagnetic Fault Injection in LOGO! V8.3 BM Devices Results in Broken LOGO! V8.3 Product CA
Published
Sept. 10, 2024, 2 a.m.
Summary
LOGO! V8.3 BM (incl. SIPLUS variants) devices contain a vulnerability that could allow an electromagnetic fault injection. This could allow an attacker to dump and debug the firmware, including the manipulation of memory. Further actions could allow to inject public keys of custom created key pairs which are then signed ...
Title
SSA-883918 V1.1 (Last Update: 2024-09-10): Information Disclosure Vulnerability in SIMATIC WinCC
Published
Sept. 10, 2024, 2 a.m.
Summary
Multiple versions of SIMATIC WinCC and SIMATIC PCS 7 do not properly handle certain requests to their web application (WinCC WebNavigator, PCS 7 Web Server, and PCS 7 Web Diagnostics Server), which may lead to the leak of privileged information. This could allow an unauthenticated remote attacker to retrieve information ...

Last Updates

BOSCH PSIRT
14.08.2025
SIEMENS CERT
09.09.2025
US CERT
25.08.2025
US CERT (ICS)
09.09.2025

By Source

Archive

2025
2024
2023
2022
2021
2020
2019
2018
2017

Feeds