SIEMENS CERT
08/10/2021
A vulnerability in S7-300 might allow an attacker to cause a Denial-of-Service condition on port 102 of the affected devices by sending specially crafted packets. Siemens is preparing updates and recommends specific countermeasures until fixes are available.
SIEMENS CERT
08/10/2021
Security researchers discovered and disclosed 33 vulnerabilities in several open-source TCP/IP stacks for embedded devices, also known as “AMNESIA:33” vulnerabilities. This advisory describes the impact of two of these vulnerabilities (CVE-2020-13987, CVE-2020-17437) to Siemens products. Siemens has released updates for several affected products and recommends to update to the latest …
SIEMENS CERT
08/10/2021
Siemens SCALANCE W1750D is a brand-labeled device. Aruba has released a related security advisory ARUBA-PSA-2021-007 disclosing vulnerabilities in its Aruba Instant product line. Siemens is preparing updates and recommends countermeasures for products where updates are not, or not yet available.
SIEMENS CERT
08/10/2021
There are multiple vulnerabilities in an underlying Link Layer Discovery Protocol (LLDP) third party library. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available.
SIEMENS CERT
08/10/2021
The Video Server application in SiNVR/SiVMS solutions contains five vulnerabilities involving information disclosure (CVE-2019-19291, CVE-2019-19299), path traversal (CVE-2019-19296, CVE-2019-19297), and denial-of-service (CVE-2019-19298). PKE has released updates of the application that fixes the reported vulnerabilities, except for CVE-2019-19299. This update is not available under the former Siemens OEM brand name SiNVR. …
SIEMENS CERT
08/10/2021
A vulnerability in affected devices could allow an attacker to perform a denial-of-service attack if a large amount of Profinet Discovery and Configuration Protocol (DCP) reset packets is sent to the affected devices. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens …
SIEMENS CERT
08/10/2021
Intel has published information on vulnerabilities in Intel products in November 2020. This advisory lists the Siemens IPC related products, that are affected by these vulnerabilities. In this advisory we take a representative CVE from each advisory: “Intel CSME, SPS, TXE, AMT and DAL Advisory” Intel-SA-00391 is represented by CVE-2020-8745 …
SIEMENS CERT
08/10/2021
Siemens has released version V13.2.0.1 for JT2Go and Teamcenter Visualization to fix multiple vulnerabilities that could be triggered when the products read files in different file formats (CGM, DGN, DXF, and DWG). If a user is tricked to open a malicious file with the affected products, this could lead the …